12 research outputs found

    Suppression of electrical breakdown phenomena in liquid TriMethyl Bismuth based ionization detectors

    Full text link
    Organometallic liquids provide good properties for ionization detectors. TriMethyl Bismuth (TMBi) has been proposed as a detector medium with charge and Cherenkov photon readout for Positron Emission Tomography. In this work, we present studies for the handling of TMBi at different electric fields and under different environmental conditions to find applicable configurations for the suppression of electrical breakdowns in TMBi at room temperature. A simple glass cell with two electrodes filled with TMBi was constructed and tested under different operation conditions. Working at the vapour pressure of TMBi at room temperature of about 40 mbar and electric fields of up to 20 kV/cm in presence of a small oxygen contamination we found the formation of a discharge channel in the liquid and a steady increase in the current. Further reduction of pressure by pumping caused the TMBi to boil and a spontaneous combustion. Eliminating the oxygen contamination led the TMBi under the same condition to only decompose. When operating the setup under an argon atmosphere of 1 bar we did not observe breakdowns of the electrical potential up to field strengths of 20 kV/cm. Still, in presence of a small oxygen contamination fluctuating currents in the nA range were observed, but no decomposition or combustion. We conclude from our experiments that TMBi at room temperature in a pure argon atmosphere of 1 bar remains stable against electrical breakdown at least up to electric field strengths of 20 kV/cm, presumably because the formation of gaseous TMBi was prevented.Comment: 14 page, 8 figure

    Magnetically-coupled piston pump for high-purity gas applications

    Full text link
    Experiments based on noble elements such as gaseous or liquid argon or xenon utilize the ionization and scintillation properties of the target materials to detect radiation-induced recoils. A requirement for high light and charge yields is to reduce electronegative impurities well below the ppb level. To achieve this, the target material is continuously circulated in the gas phase through a purifier and returned to the detector. Additionally, the low backgrounds necessary dictate low-Rn-emanation rates from all components that contact the gas. Since commercial pumps often introduce electronegative impurities from lubricants on internal components or through small air leaks, and are not designed to meet the radiopurity requirements, custom-built pumps are an advantageous alternative. A new pump has been developed in Muenster in cooperation with the nEXO group at Stanford University and the nEXO/XENON group at Rensselaer Polytechnic Institute based on a magnetically-coupled piston in a hermetically sealed low-Rn-emanating vessel. This pump delivers high performance for noble gases, reaching more than 210 standard liters per minute (slpm) with argon and more than 170 slpm with xenon while maintaining a compression of up to 1.9 bar, demonstrating its capability for noble gas detectors and other applications requiring high standards of gas purity.Comment: 11 pages, 18 figure

    Systematic Evaluation of Fluorination as Modification for Peptide‐Based Fusion Inhibitors against HIV‐1 Infection

    Get PDF
    With the emergence of novel viruses, the development of new antivirals is more urgent than ever. A key step in human immunodeficiency virus type 1 (HIV-1) infection is six-helix bundle formation within the envelope protein subunit gp41. Selective disruption of bundle formation by peptides has been shown to be effective; however, these drugs, exemplified by T20, are prone to rapid clearance from the patient. The incorporation of non-natural amino acids is known to improve these pharmacokinetic properties. Here, we evaluate a peptide inhibitor in which a critical Ile residue is replaced by fluorinated analogues. We characterized the influence of the fluorinated analogues on the biophysical properties of the peptide. Furthermore, we show that the fluorinated peptides can block HIV-1 infection of target cells at nanomolar levels. These findings demonstrate that fluorinated amino acids are appropriate tools for the development of novel peptide therapeutics

    Rhetorical Transformations in Multimodal Advertising Texts: From General to Local Degree Zero

    Get PDF
    The use of rhetoric in advertising research has been steadily gaining momentum since the 1980’s. Coupled with an increased interest in multimodality and the multiple interactions among verbal, pictorial and auditory registers, as structural components of an ad filmic text, the hermeneutic tools furnished by traditional rhetoric have been expanded and elaborated. This paper addresses the fundamental question of how ad filmic texts assume signification from a multimodal rhetorical point of view, by engaging in a fruitful dialogue with various research streams within the wider semiotic discipline and consumer research. By critically addressing the context of analysis of a multimodal ad text in the course of the argumentation deployed by different approaches, such as Social Semiotics (Kress/Leeuwen 2001), Film Semiotics (i.e. Metz 1982, Carroll 1980, Branigan 1982), Visual Semiotics (i.e. Sonesson 2008; 2010, Eco 1972;1976;1986, Groupe " 1992), Consumer Research (i.e. Mick/McQuarrie 1999; 2004, Philips 2003, Scott 1994), the relative merits of a structuralist approach that prioritizes the distinction between local and general degree zero, as put forward by Groupe " (1992), are highlighted. Furthermore, the modes whereby rhetorical transformations are enacted are outlined, with view to deepening the conceptual tackling of degree zero of signification, while addressing its applicability to branding discourse and multimodal ad texts

    Systematic Evaluation of Fluorination as Modification for Peptide-Based Fusion Inhibitors against HIV-1 Infection

    No full text
    With the emergence of novel viruses, the development of new antivirals is more urgent than ever. A key step in human immunodeficiency virus type 1 (HIV-1) infection is six-helix bundle formation within the envelope protein subunit gp41. Selective disruption of bundle formation by peptides has been shown to be effective; however, these drugs, exemplified by T20, are prone to rapid clearance from the patient. The incorporation of non-natural amino acids is known to improve these pharmacokinetic properties. Here, we evaluate a peptide inhibitor in which a critical Ile residue is replaced by fluorinated analogues. We characterized the influence of the fluorinated analogues on the biophysical properties of the peptide. Furthermore, we show that the fluorinated peptides can block HIV-1 infection of target cells at nanomolar levels. These findings demonstrate that fluorinated amino acids are appropriate tools for the development of novel peptide therapeutics

    Hand MRI and the Greulich-Pyle atlas in skeletal age estimation in adolescents

    No full text
    Objective To evaluate the feasibility of hand MRI in age assessment in adolescents using the Greulich-Pyle (GP) atlas criteria. Materials and methods Two radiologists, who were blinded to the study subjects chronologic ages, semi-objectively evaluated 1.5-T MRIs of the left hands of ten patients (13.52.6 years) who had left-hand radiographs and 50 healthy volunteers (152 years). Results A coronal T1-weighted, volumetric, interpolated, breath-hold examination with water excitation (T1 VIBE-3D-WE) achieved the best image quality. The correlation between estimated patients ages on radiographs and MRI was high. The average estimated age difference between the MRIs and radiographs was 0.05 years for reader 1 and 0.175 years for reader 2. The interclass coefficients (ICCs) showed high interobserver agreement (radiographs: ICC=0.95, MRI: ICC=0.97). The ICC, calculated separately for the male and female volunteers estimated ages by MRI, also showed a high agreement between the two readers (male: ICC=0.97, female: ICC=0.95). Reader 1 estimated 94% of volunteers within 2 standard deviations (SD) and 62% within 1 SD. The results for reader 2 were 92% and 54%, respectively. Thirty-nine percent of girls and 27% of boys were estimated to be older using 1 SD. Conclusion MRI of the left hand is a feasible alternative to hand radiographs for skeletal age estimation in adolescents using the GP criteria with 2 SD. Using 1 SD, the age of healthy volunteers tended to be estimated as higher than the chronologic age. Future studies should evaluate the results in a larger number of participants.(VLID)358223

    Unenhanced MDCT in patients with suspected urinary stone disease: do coronal reformations improve diagnostic performance?

    No full text
    OBJECTIVE: The objectives of our study were to assess whether coronal reformations improve the diagnostic performance of MDCT in patients with acute flank pain and suspected urinary stone disease; and to determine if performing such reformations from 3-mm-thick sections is sufficient or if it is necessary to perform reformations from thinner sections. MATERIALS AND METHODS: We included 147 consecutive patients (72 women and 75 men; mean age +/- SD, 58 +/- 18.1 years) with suspected urinary stone disease who underwent unenhanced MDCT. Scans were obtained with a 4 x 1 mm collimation and were reconstructed with a section thickness of 1.25 and 3 mm. We compared the diagnostic yield of 3-mm axial sections with that of coronal reformations reconstructed from 1.25- and 3-mm axial sections. Imaging data were evaluated in random order by two radiologists. The significance of the difference between the axial sections and coronal multiplanar reformations (MPRs) was tested for the number, size, and location of uroliths and for the presence of alternative diagnoses. The time required for review by both observers was recorded. RESULTS: We found uroliths in 72 patients. There was no difference between 3-mm axial sections and coronal reformations from 1.25-mm sections with regard to the number of detected stones (n = 264 for both protocols), whereas coronal reformations from 3-mm sections revealed significantly fewer calcifications (n = 255, p = 0.016). Coronal reformations did not improve the localization of calcifications. Review time, however, was significantly shorter for coronal reformations than for axial sections (p = 0.001); however, coronal reformations were less sensitive than axial sections for the detection of additional findings suggestive of alternative diagnoses in 16 (30%) of 53 patients. CONCLUSION: Coronal reformations from MDCT do not improve urinary stone detection but may reduce evaluation time; however, there is the danger of missing additional findings. Coronal reformations reconstructed from thick (i.e., 3-5 mm) axial sections may result in reduced detection of small stones and should therefore be avoide

    Sodium MR imaging of the lumbar intervertebral disk at 7 T: correlation with T2 mapping and modified Pfirrmann score at 3 T - preliminary results

    Full text link
    PURPOSE: To compare sodium imaging of lumbar intervertebral disks in asymptomatic volunteers at 7-T magnetic resonance (MR) imaging with quantitative T2 mapping and morphologic scoring at 3 T. MATERIALS AND METHODS: Following ethical board approval and informed consent, the L2-3 to L5-S1 disks were examined in 10 asymptomatic volunteers (nine men, one woman; mean age, 30 years; range, 23-43 years). At 7 T, normalized sodium signal-to-noise ratios were calculated, by using region-of-interest analysis. At 3 T, T2 mapping was performed with a multiecho spin-echo sequence (repetition time msec/echo times msec, 1500/24, 36, 48, 60, 72, 84, 96, 108, 120, 132, 144, 156). T2 values were calculated over the nucleus, with a pixelwise, monoexponential nonnegative least-squares-fit analysis. Morphologic grading according to a modified Pfirrmann score was assessed independently by three experienced musculoskeletal radiologists, and Pearson correlation analysis of the covariates was performed. RESULTS: The mean normalized sodium signal intensity was 275.5±115.4 (standard deviation). The T2 mapping showed a mean value of 89.8 msec±19.34. The median modified Pfirrmann score was 2b (90% had score≤3c). The Pearson correlation coefficient showed a cubic function between sodium imaging and the modified Pfirrmann score, a moderate inverse correlation between T2 mapping and the modified Pfirrmann score (r=-0.62), and no correlation between sodium imaging and T2 mapping (r=0.06). CONCLUSION: The results suggest that MR imaging of the intervertebral disk, using sodium imaging and T2 mapping, can help characterize different component changes and that both of these methods are to some degree related to the Pfirrmann score
    corecore