27 research outputs found

    Transport of mucoid mucus in healthy individuals and patients with chronic obstructive pulmonary disease and bronchiectasis

    Get PDF
    Objective: To characterise and compare the in vitro transport properties of respiratory mucoid secretion in individuals with no lung disease and in stable patients with chronic obstructive pulmonary disease (COPD) and bronchiectasis.Methodology: Samples of mucus were collected, from 21 volunteers presenting no lung disease who had undergone surgery, from 10 patients presenting chronic COPD, and from 16 patients with bronchiectasis. Mucociliary transport (MCT), transport by cough (SCM), and contact angle (CAM) were evaluated.Results: MCT was found to be greater in healthy individuals (1.0 +/- 0.19) than in COPD (0.91 +/- 0.17) and bronchiectasis (0.76 +/- 0.23) patients (p < 0.05), whereas SCM was greater in COPD patients (16.31 +/- 7.35 cm) than in patients with bronchiectasis (12.16 +/- 6.64 cm) and healthy individuals (10.50 +/- 25.8 cm) (p < 0.05). No significant differences were observed between the groups regarding CAM.Conclusion: Mucus from healthy individuals allows better mucociliary transport compared to that from patients with lung diseases. However, the mucus from COPD patients allows a better transport by coughing, demonstrating that these individuals have adapted to a defence mechanism compared to patients with bronchiectasis, who have impairment in their ciliary and cough transport mechanisms. (c) 2012 Sociedade Portuguesa de Pneumologia. Published by Elsevier Espana, S.L. All rights reserved.Ctr Univ Tridngulo, Dept Fisioterapia, Uberlandia, MG, BrazilFac Med Ribeirao Preto, Dept Fisioterapia, Ribeirao Preto, BrazilUniversidade Federal de São Paulo, Dept Pneumol, São Paulo, BrazilFac Med Ribeirao Preto, Dept Pneumol, Ribeirao Preto, BrazilUniversidade Federal de São Paulo, Dept Pneumol, São Paulo, BrazilWeb of Scienc

    Avaliação da força muscular inspiratória (PImáx) durante o desmame da ventilação mecânica em pacientes neurológicos internados na unidade de terapia intensiva

    Get PDF
    Mechanical ventilation, often needed in critically ill patients, may be associated to loss of respiratory muscular force due to several mechanisms. The objective was to assess the progression of respiratory muscular force during weaning from mechanical ventilation by using serial measurement of maximum inspiratory pressure until complete discontinuation in neurological patients. The PImax was progressively assessed by using manovacuometer and unidirectional valve once a day during the whole period of mechanical ventilation weaning. Thirty-one neurological patients (after stroke or craniocerebral trauma) undergoing weaning from mechanical ventilation were included for study, and the values obtained were compared to those established by Black and Hyatt. The initial mean PImax (first day of weaning) was - 40.0±20.0 cmH2O (39% of the expected value) (p < 0.05), reaching 50% at day 5 and 60% at day 10. It was observed an increase of 21% (p < 0.05) between the first and tenth days. On the 13th day, mechanical ventilation had been completely discontinued in all patients. Therefore a progressive evaluation of the inspiratory muscular force in patients undergoing prolonged mechanical ventilation shows that the complete discontinuation is possible in neurological patients with 72% of the established values.A ventilação mecânica, freqüentemente necessária em pacientes em estado crítico, pode ser associada à perda de força muscular respiratória por diversos mecanismos. Nosso objetivo foi avaliar a progressão da força da musculatura respiratória durante o processo de desmame, por mensuração seriada da PImáx até a independência completa da ventilação mecânica em pacientes neurológicos. A PImáx foi avaliada evolutivamente, uma vez ao dia, durante todo o período de desmame, com auxílio de manovacuômetro e válvula unidirecional. Foram incluídos no estudo 31 pacientes neurológicos (pós acidente vascular ou trauma crânio-encefálico) em desmame ventilatório e os valores obtidos foram comparados aos previstos, segundo Black e Hyatt. A média de PImáx inicial (primeiro dia do desmame) foi - 40,0±20,0 cmH2O (39% do previsto) (p< 0, 05); 50% no 5º e 60% no 10º dia de desmame. Houve um aumento de 21% (

    Training Status as a Marker of the Relationship between Nitric Oxide, Oxidative Stress, and Blood Pressure in Older Adult Women

    Get PDF
    The purpose of this study was to evaluate the influence of functional fitness and oxidative capacity on the nitric oxide concentration associated with hemodynamic control in older adult women. The sample consisted of 134 women (65.73 ± 6.14 years old). All subjects underwent a physical examination to assess body mass index, waist-hip ratio, body fat measurement by dual energy X-ray absorptiometry, and blood pressure (BP). Training status (TS) was evaluated by indirect determination of maximal oxygen uptake by a treadmill test using Balke protocol modified for older adults. Functional fitness was also evaluated through a “Functional Fitness Battery Test” to determine the general fitness functional index (GFFI). All participants were separated according to the functional fitness (TS1, very weak and weak; TS2, regular; TS3, good and very good). Plasma blood samples were used to evaluate prooxidant and antioxidant activity and nitrite and nitrate concentrations. The general results of this study showed that good levels of TS were related to lower levels of lipoperoxidation and protein damage, higher levels of antioxidant, and higher concentration of nitrite and nitrate. This combination may be responsible for the lower levels of BP in subjects with better TS

    Combined effects of angiotensin receptor blocker use and physical training in hypertensive men

    No full text
    Purpose Pharmacological (angiotensin II receptor type 1 receptor blocker use) and non-pharmacological treatment (physical aerobic exercise) are important strategies to reduces blood pressure and control arterial hypertension; however, only few clinical studies have evaluated their combined effects on autonomic cardiovascular control. Therefore, we investigated the effect of a combination intervention that involved losartan administration and physical aerobic training on autonomic cardiovascular control. Methods Thirty-two men (aged 40 to 60 years) were assigned into two groups: normotensive group, without any pharmacological treatment (NG, N = 16), or hypertensive group, with losartan administration (HG, N = 16). They underwent a physical aerobic training for 16 weeks, thrice a week. Hemodynamic parameters, heart rate variability (HRV), blood pressure variability, and spontaneous baroreflex sensitivity (BRS) were measured before and after training. Results Before training, both the groups showed similar values of hemodynamic parameters. However, the HG showed decreased BRS and HRV, characterized by reduction in sympathetic (p = .02) and vagal (p < .001) modulation. After training, the NG exhibited decreased heart rate (HR) at rest (p < .001), whereas the HG showed decreased HR at rest (p < .001) and blood pressure (BP) (p = .001). The HG showed decreased sympathetic modulation (p = .02) and increased BRS (p < .001) and vagal modulation (p < .001), but HRV (p < .001) and BRS gain (p < .001) remained significantly lower when compared to the NG. Conclusions Physical aerobic training was essential to improve the BRS and HRV cardiac autonomic modulation in the HG. However, it was not sufficient to normalize the analyzed autonomic parameters

    The influence of Flutter (R) VRP1 components on mucus transport of patients with bronchiectasis

    No full text
    Background: The Flutter (R) VRP1 combines high frequency oscillation and positive expiratory pressure (PEP). Objective: To separately evaluate the effect of the Flutter (R) VRP1 components (high frequency oscillation and PEP) on mucus transportability in patients with bronchiectasis. Methods: Eighteen patients with bronchiectasis received sessions with the Flutter (R) VRP1 or PEP for 30 min daily in a randomized, crossover study. The treatment duration was four weeks with one of the therapies, one week of a ""wash-out"" period and followed by four more weeks with the other treatment. Weekly secretion samples were collected and evaluated for mucociliary relative transport velocity (RTV), displacement in a simulated cough machine (SCM) and contact angle measurement (CAM). For the proposed comparisons, a linear regression model was used with mixed effects with a significance level of 5%. Results: The Flutter (R) VRP1 treatment resulted in greater displacement in SCM and lower CAM when comparing results from the first (9.6 +/- 3.4 cm and 29.4 +/- 5.7 degrees, respectively) and fourth weeks of treatment (12.44 +/- 10.5 cm and 23.28 +/- 6.2, respectively; p < 0.05). There was no significant difference in the RTV between the treatment weeks for either the Flutter (R) VRP1 or PEP. Conclusion: The use of the Flutter (R) VRP1 for four weeks is capable of altering the respiratory secretion transport properties, and this alteration is related to the high frequency oscillation component. (C) 2011 Elsevier Ltd. All rights reserved

    Respiratory system impedance in different decubitus evaluated by impulse oscillometry in individuals with obesity.

    No full text
    Background and objectiveThe body posture can influence gas exchange, respiratory mechanics, and mucociliary clearance and different positions can be used as a therapeutic strategy to improve in gas exchange and can also help physiotherapists to assist patients who have difficult or restrictions to stay seated or the ones who stay in the same position for a long period. The objective of this study was to evaluate the effect of different positions on respiratory system impedance in obese and eutrophic subjects, using Impulse Oscillometry System (IOS).MethodsThe IOS parameters were evaluated in seated (Se), right lateral decubitus (RL), left lateral decubitus (LL), and supine (Su).ResultsSixty two volunteers were allocated in obese group (OG) or eutrophic group (EG) according to BMI. In seated position, OG showed higher impedance than EG for R5: 0.55 (0.31; 0.93) and 0.33 (0.24; 0.52); R20: 0.39 (0.23; 0.54) and 0.32 (0.03; 0.41); R5-R20: 0.13 (0.02; 0.47) and 0.01 (-0.08; 0.27); X5: -0.20 (-0.51; 0.16) and -0,10 (-0.016; -0.04); Fres: 20.59 (11.54; 36.45 and 10.69 (7.56; 24.7) (pConclusionThe respiratory system impedance is increased in OG, with greater contribution of peripheral resistance. The higher values of resistance and reactance were obtained in the supine position, in both groups, with lower differences obtained in the right and left lateral decubitus
    corecore