26 research outputs found

    A Rapid, Handheld Device to Assess Respiratory Resistance: Clinical and Normative Evidence

    Get PDF
    Introduction: Following reports of respiratory symptoms among service members returning from deployment to South West Asia (SWA), an expert panel recommended pre-deployment spirometry be used to assess disease burden. Unfortunately, testing with spirometry is high cost and time-consuming. The airflow perturbation device (APD) is a handheld monitor that rapidly measures respiratory resistance (APD-Rr) and has promising but limited clinical data. Its speed and portability make it ideally suited for large volume pre-deployment screening. We conducted a pilot study to assess APD performance characteristics and develop normative values. Materials and Methods: We prospectively enrolled subjects and derived reference equations for the APD from those without respiratory symptoms, pulmonary disease, or tobacco exposure. APD testing was conducted by medical technicians who received a 10-min in-service on its use. A subset of subjects performed spirometry and impulse oscillometry (iOS), administered by trained respiratory therapists. APD measures were compared with spirometry and iOS. Results: The total study population included 199 subjects (55.8% males, body mass index 27.7 ± 6.0 kg/m2, age 49.9 ± 18.7 yr). Across the three APD trials, mean inspiratory (APD-Ri), expiratory (APD-Re), and average (APD-Ravg) resistances were 3.30 ± 1.0, 3.69 ± 1.2, and 3.50 ± 1.1 cm H2O/L/s. Reference equations were derived from 142 clinically normal volunteers. Height, weight, and body mass index were independently associated with APD-Ri, APD-Re, and APD-Ravg and were combined with age and gender in linear regression models. APD-Ri, APD-Re, and APD-Ravg were significantly inversely correlated with FEV1 (r = −0.39 to −0.42), FVC (r = −0.37 to −0.40), and FEF25–75 (r = −0.31 to −0.35) and positively correlated with R5 (r = 0.61–0.62), R20 (r = 0.50–0.52), X5 (r = −0.57 to −0.59), and FRES (r = 0.42–0.43). Bland–Altman plots showed that the APD-Rr closely approximates iOS when resistance is normal. Conclusion: Rapid testing was achieved with minimal training required, and reference equations were constructed. APD-Rr correlated moderately with iOS and weakly with spirometry. More testing is required to determine whether the APD has value for pre- and post-deployment respiratory assessment

    A Search for Possible Long Range Spin Dependent Interactions of the Neutron from Exotic Vector Boson Exchange

    Get PDF
    We present a search for possible spin dependent interactions of the neutron with matter through exchange of spin 1 bosons with axial vector couplings as envisioned in possible extensions of the Standard Model. This was sought using a slow neutron polarimeter that passed transversely polarized slow neutrons by unpolarized slabs of material arranged so that interactions would tilt the plane of polarization and develop a component along the neutron momentum. The result for the rotation angle, ϕâ€Č=[2.8±4.6(stat.)±4.0(sys.)]×10−5 rad/m is consistent with zero. This result improves the upper bounds on the neutron-matter coupling g2A by about three orders of magnitude for force ranges in the mm– ÎŒm regime

    Observation of gravitational waves from the coalescence of a 2.5−4.5 M⊙ compact object and a neutron star

    Get PDF

    Search for eccentric black hole coalescences during the third observing run of LIGO and Virgo

    Get PDF
    Despite the growing number of confident binary black hole coalescences observed through gravitational waves so far, the astrophysical origin of these binaries remains uncertain. Orbital eccentricity is one of the clearest tracers of binary formation channels. Identifying binary eccentricity, however, remains challenging due to the limited availability of gravitational waveforms that include effects of eccentricity. Here, we present observational results for a waveform-independent search sensitive to eccentric black hole coalescences, covering the third observing run (O3) of the LIGO and Virgo detectors. We identified no new high-significance candidates beyond those that were already identified with searches focusing on quasi-circular binaries. We determine the sensitivity of our search to high-mass (total mass M>70 M⊙) binaries covering eccentricities up to 0.3 at 15 Hz orbital frequency, and use this to compare model predictions to search results. Assuming all detections are indeed quasi-circular, for our fiducial population model, we place an upper limit for the merger rate density of high-mass binaries with eccentricities 0<e≀0.3 at 0.33 Gpc−3 yr−1 at 90\% confidence level

    Ultralight vector dark matter search using data from the KAGRA O3GK run

    Get PDF
    Among the various candidates for dark matter (DM), ultralight vector DM can be probed by laser interferometric gravitational wave detectors through the measurement of oscillating length changes in the arm cavities. In this context, KAGRA has a unique feature due to differing compositions of its mirrors, enhancing the signal of vector DM in the length change in the auxiliary channels. Here we present the result of a search for U(1)B−L gauge boson DM using the KAGRA data from auxiliary length channels during the first joint observation run together with GEO600. By applying our search pipeline, which takes into account the stochastic nature of ultralight DM, upper bounds on the coupling strength between the U(1)B−L gauge boson and ordinary matter are obtained for a range of DM masses. While our constraints are less stringent than those derived from previous experiments, this study demonstrates the applicability of our method to the lower-mass vector DM search, which is made difficult in this measurement by the short observation time compared to the auto-correlation time scale of DM

    Different Finite Durations of Anticoagulation and Outcomes following Idiopathic Venous Thromboembolism: A Meta-Analysis

    Get PDF
    Introduction. Controversy remains over the optimal length of anticoagulation following idiopathic venous thromboembolism. We sought to determine if a longer, finite course of anticoagulation offered additional benefit over a short course in the initial treatment of the first episode of idiopathic venous thromboembolism. Data Extraction. Rates of deep venous thrombosis, pulmonary embolism, combined venous thromboembolism, major bleeding, and mortality were extracted from prospective trials enrolling patients with first time, idiopathic venous thromboembolism. Data was pooled using random effects meta-regression. Results. Ten trials, with a total of 3225 patients, met inclusion criteria. For each additional month of initial anticoagulation, once therapy was stopped, recurrent venous thromboembolism (0.03 (95% CI: −0.28 to 0.35); =.24), mortality (−0.10 (95% CI: −0.24 to 0.04); =.15), and major bleeding (−0.01 (95% CI: −0.05 to 0.02); =.44) rates measured in percent per patient years, did not significantly change. Conclusions: Patients with an initial idiopathic venous thromboembolism should be treated with 3 to 6 months of secondary prophylaxis with vitamin K antagonists. At that time, a decision between continuing with indefinite therapy can be made, but there is no benefit to a longer (but finite) course of therapy

    Prevention, diagnosis and treatment of venous thromboembolism in patients with COVID-19: CHEST Guideline and Expert Panel Report.

    Get PDF
    BACKGROUND Emerging evidence shows that severe COVID-19 can be complicated by a significant coagulopathy, that likely manifests in the form of both microthrombosis and venous thromboembolism (VTE). This recognition has led to the urgent need for practical guidance regarding prevention, diagnosis, and treatment of VTE. METHODS A group of approved panelists developed key clinical questions by using the PICO (population, intervention, comparator, and outcome) format that addressed urgent clinical questions regarding the prevention, diagnosis and treatment of venous thromboembolism in patients with COVID-19. MEDLINE (via PubMed or Ovid), Embase and Cochrane Controlled Register of Trials were systematically searched for relevant literature and references were screened for inclusion. Validated evaluation tools were used to grade the level of evidence to support each recommendation. When evidence did not exist, guidance was developed based on consensus using the modified Delphi process. RESULTS The systematic review and critical analysis of the literature based on13 PICO questions resulted in 22 statements. Very little evidence exists in the COVID-19 population. The panel thus used expert consensus and existing evidence-based guidelines to craft the guidance statements. CONCLUSIONS The evidence on the optimal strategies to prevent, diagnose, and treat venous thromboembolism in patients with COVID-19 is sparse, but rapidly evolving

    A Rapid, Handheld Device to Assess Respiratory Resistance: Clinical and Normative Evidence

    Get PDF
    Introduction: Following reports of respiratory symptoms among service members returning from deployment to South West Asia (SWA), an expert panel recommended pre-deployment spirometry be used to assess disease burden. Unfortunately, testing with spirometry is high cost and time-consuming. The airflow perturbation device (APD) is a handheld monitor that rapidly measures respiratory resistance (APD-Rr) and has promising but limited clinical data. Its speed and portability make it ideally suited for large volume pre-deployment screening. We conducted a pilot study to assess APD performance characteristics and develop normative values. Materials and Methods: We prospectively enrolled subjects and derived reference equations for the APD from those without respiratory symptoms, pulmonary disease, or tobacco exposure. APD testing was conducted by medical technicians who received a 10-min in-service on its use. A subset of subjects performed spirometry and impulse oscillometry (iOS), administered by trained respiratory therapists. APD measures were compared with spirometry and iOS. Results: The total study population included 199 subjects (55.8% males, body mass index 27.7 ± 6.0 kg/m2, age 49.9 ± 18.7 yr). Across the three APD trials, mean inspiratory (APD-Ri), expiratory (APD-Re), and average (APD-Ravg) resistances were 3.30 ± 1.0, 3.69 ± 1.2, and 3.50 ± 1.1 cm H2O/L/s. Reference equations were derived from 142 clinically normal volunteers. Height, weight, and body mass index were independently associated with APD-Ri, APD-Re, and APD-Ravg and were combined with age and gender in linear regression models. APD-Ri, APD-Re, and APD-Ravg were significantly inversely correlated with FEV1 (r = −0.39 to −0.42), FVC (r = −0.37 to −0.40), and FEF25–75 (r = −0.31 to −0.35) and positively correlated with R5 (r = 0.61–0.62), R20 (r = 0.50–0.52), X5 (r = −0.57 to −0.59), and FRES (r = 0.42–0.43). Bland–Altman plots showed that the APD-Rr closely approximates iOS when resistance is normal. Conclusion: Rapid testing was achieved with minimal training required, and reference equations were constructed. APD-Rr correlated moderately with iOS and weakly with spirometry. More testing is required to determine whether the APD has value for pre- and post-deployment respiratory assessment
    corecore