164 research outputs found

    Modeling a Nb\u3csub\u3e3\u3c/sub\u3eSn Cryounit in GPT at UITF

    Get PDF
    Nb3Sn is a prospective material for future superconducting radio frequency (SRF) accelerator cavities. Compared to conventional niobium, the material can achieve higher quality factors, higher temperature operation, and potentially higher accelerating gradients (Eacc ≈ 96 MV/m). In this work, we performed modeling of the Upgraded Injector Test Facility (UITF) at Jefferson Lab utilizing newly constructed Nb3Sn cavities. We studied the effects of the buncher cavity and varied the gun voltage from 200-500 keV. We have calibrated and optimized the SRF cavity gradients and phases for the Nb3Sn five-cell cavities\u27 energy gains with the framework of the General Particle Tracer (GPT). Our calculations show the beam goes cleanly through the unit. There is full energy gain out of the second SRF cavity but not from the first SRF cavity due to non-relativistic phase shifts

    Narrow-Band Emission in Thomson Sources Operating in the High-Field Regime

    Get PDF
    We present a novel and quite general analysis of the interaction of a high-field chirped laser pulse and a relativistic electron, in which exquisite control of the spectral brilliance of the up-shifted Thomson-scattered photon is shown to be possible. Normally, when Thomson scattering occurs at high field strengths, there is ponderomotive line broadening in the scattered radiation. This effect makes the bandwidth too large for some applications and reduces the spectral brilliance. We show that such broadening can be corrected and eliminated by suitable frequency modulation of the incident laser pulse. Furthermore, we suggest a practical realization of this compensation idea in terms of a chirped-beam-driven free electron laser oscillator configuration and show that significant compensation can occur, even with the imperfect matching to be expected in these conditions

    Nonlinear natural engine: Model for thermodynamic processes in mesoscale systems

    Full text link

    Simultaneous Optimization of the Cavity Heat Load and Trip Rates in Linacs Using a Genetic Algorithm

    Get PDF
    In this paper, a genetic algorithm-based optimization is used to simultaneously minimize two competing objectives guiding the operation of the Jefferson Lab\u27s Continuous Electron Beam Accelerator Facility linacs: cavity heat load and radio frequency cavity trip rates. The results represent a significant improvement to the standard linac energy management tool and thereby could lead to a more efficient Continuous Electron Beam Accelerator Facility configuration. This study also serves as a proof of principle of how a genetic algorithm can be used for optimizing other linac-based machines

    Beam Dynamics Studies of Parallel-Bar Deflecting Cavities

    Get PDF
    We have performed three-dimensional simulations of beam dynamics for parallel-bar transverse electromagnetic mode (TEM) type RF separators: normal- and superconducting. The compact size of these cavities as compared to conventional TM110 type structures is more attractive particularly at low frequency. Highly concentrated electromagnetic fields between the parallel bars provide strong electrical stability to the beam for any mechanical disturbance. An array of eight 2-cell normal conducting cavities or a one- or two-cell superconducting structure are enough to produce the required vertical displacement at the Lambertson magnet. Both the normal and superconducting structures show very small emittance dilution due to the vertical kick of the beam

    Bunch Length Measurements at the CEBAF Injector at 130 kV

    Get PDF
    In this work, we investigated the evolution in bunch length of beams through the CEBAF injector for low to high charge per bunch. Using the General Particle Tracer (GPT), we have simulated the beams through the beamline of the CEBAF injector and analyzed the beam to get the bunch lengths at the location of chopper. We performed these simulations with the existing injector using a 130 kV gun voltage. Finally, we describe measurements to validate these simulations. The measurements have been done using chopper scanning technique for two injector laser drive frequency modes: one with 500 MHz, and another with 250 MHz

    Improved Functional Outcome After Peripheral Nerve Stimulation of the Impaired Forelimb Post-stroke

    Get PDF
    Lack of blood flow to the brain, i.e., ischemic stroke, results in loss of nerve cells and therefore loss of function in the effected brain regions. There is no effective treatment to improve lost function except restoring blood flow within the first several hours. Rehabilitation strategies are widely used with limited success. The purpose of this study was to examine the effect of electrical stimulation on the impaired upper extremity to improve functional recovery after stroke. We developed a rodent model using an electrode cuff implant onto a single peripheral nerve (median nerve) of the paretic forelimb and applied daily electrical stimulation. The skilled forelimb reaching test was used to evaluate functional outcome after stroke and electrical stimulation. Anterograde axonal tracing from layer V pyramidal neurons with biotinylated dextran amine was done to evaluate the formation of new neuronal connections from the contralesional cortex to the deafferented spinal cord. Rats receiving electrical stimulation on the median nerve showed significant improvement in the skilled forelimb reaching test in comparison with stroke only and stroke with sham stimulation. Rats that received electrical stimulation also exhibited significant improvement in the latency to initiate adhesive removal from the impaired forelimb, indicating better sensory recovery. Furthermore, axonal tracing analysis showed a significant higher midline fiber crossing index in the cervical spinal cord of rats receiving electrical stimulation. Our results indicate that direct peripheral nerve stimulation leads to improved sensorimotor recovery in the stroke-impaired forelimb, and may be a useful approach to improve post-stroke deficits in human patients

    Modeling a Nb\u3csub\u3e3\u3c/sub\u3eSn Cryounit in GPT in UITF

    Get PDF
    Nb₃Sn is a prospective material for future superconducting RF (SRF) accelerator cavities. The material can achieve higher quality factors, higher temperature operation and potentially higher accelerating gradients (E_{acc} 96 MV/m) compared to conventional niobium. In this work, we performed modeling of the Upgraded Injector Test Facility (UITF) at Jefferson Lab utilizing newly constructed Nb₃Sn cavities. We studied the effects of the buncher cavity and varied the gun voltages from 200-500 keV. We have calibrated and optimized the SRF cavity gradients and phases for the Nb₃Sn five-cell cavities energy gains with the framework of General Particle Tracer (GPT). Our calculations show the beam goes cleanly through the unit. There is full energy gain out of the second SRF cavity but not from the first SRF cavity due to non-relativistic phase shifts

    CEBAF Injector Model for K\u3csub\u3eL\u3c/sub\u3e Beam Conditions

    Get PDF
    The Jefferson Lab KL experiment will run at the Continuous Electron Beam Accelerator Facility with a much lower bunch repetition rate (7.80 or 15.59 MHz) than nominally used (249.5 or 499 MHz). While the proposed average current of 2.5 - 5.0 µA is relatively low compared to the maximum CEBAF current of approximately 180 µA, the corresponding bunch charge is atypically high for CEBAF injector operation. In this work, we investigated the evolution and transmission of low-rep-rate, high-bunch-charge (0.32 to 0.64 pC) beams through the CEBAF injector. Using the commercial software General Particle Tracer, we have simulated and analyzed the beam characteristics for both values of bunch charge. We performed these simulations with the existing injector using a 130 kV gun voltage. We have calculated and measured the transmission as a function of the photocathode laser spot size and pulse length. We report on the findings of these simulations and optimum parameters for operating the experiment

    Intergenerational effects of cocaine on maternal aggressive behavior and brain oxytocin in rat dams: Research Report

    Get PDF
    Gestational cocaine treatment results in significantly increased maternal aggression towards an intruder by postpartum day six, while acute postpartum treatment dose dependently decreases maternal aggressive (MA) behavior. Both increased and decreased aggression in the cocaine-treated dams are correlated with either decreased or increased levels of oxytocin in the amygdala, respectively. The current study was an effort to determine whether the effect of gestational cocaine on maternal aggression is transient or would continue into the postpartum period; whether an intermittent cocaine treatment regimen, which incorporates gestational and postpartum intermittent cocaine treatment, would differ from chronic daily gestational treatment; and finally, whether next generation female offspring of cocaine-treated or control dams would have altered MA behavior and oxytocin system changes attributable to either prenatal drug exposure, rearing condition or both. We now report no increase in maternal aggression following chronic gestational treatment and significantly lower levels of aggression in intermittently treated dams on postpartum day eight, with no significant effects in either group on postpartum day 12. Young adult female offspring of the cocaine-treated and control dams, who reared their own natural litters and were tested on postpartum day eight for maternal aggression, had higher levels of maternal aggression towards an intruder attributable to both prenatal cocaine exposure and rearing condition. Higher aggression in cocaine-reared next generation dams was associated with lower levels of oxytocin in the amygdala. Intergenerational effects of cocaine were apparent with respect to aggression and oxytocin system changes
    • …
    corecore