79 research outputs found
Measurement of Momentum Transfer Coefficients for H2, N2, CO, and CO2 Incident Upon Spacecraft Surfaces
Measurements of momentum transfer coefficients were made for gas-surface interactions between the Space Shuttle reaction control jet plume gases and the solar panel array materials to be used on the International Space Station. Actual conditions were simulated using a supersonic nozzle source to produce beams of the gases with approximately the same average velocities as the gases have in the Shuttle plumes. Samples of the actual solar panel materials were mounted on a torsion balance that was used to measure the force exerted on the surfaces by the molecular beams. Measurements were made with H2, N2, CO, and CO2 incident upon the solar array material, Kapton, SiO2-coated Kapton, and Z93-coated Al. The measurements showed that molecules scatter from the surfaces more specularly as the angle of incidence increases and that the scattering behavior has a strong dependence upon both the incident gas and velocity. These results show that for some technical surfaces the simple assumption of diffuse scattering with complete thermal accommodation is entirely inadequate. It is clear that additional measurements are required to produce models that more accurately describe the gas-surface interactions encountered in rarefied flow regimes
Hollow pellet injection for magnetic fusion
Precise delivery of mass to burning plasmas is a problem of growing interest
in magnetic fusion. The answers to how much mass is necessary and sufficient
can vary depending on parameters such as the type of atoms involved, the type
of applications, plasma conditions, mass injector, and injection timing.
Motivated by edge localized mode (ELM) control in H-mode plasmas, disruption
mitigation and other applications in magnetic fusion, we report progress and
new possibilities in mass delivery based on hollow pellets. Here, a hollow
pellet refers to a spherical shell mass structure with a hollow core. Based on
an empirical model of pellet ablation, coupled with BOUT++ simulations of ELM
triggering threshold, hollow pellets are found to be attractive in comparison
with solid spheres for ELM control. By using hollow pellets, it is possible to
tailor mass delivery to certain regions of edge plasmas while minimizing core
contamination and reducing the total amount of mass needed. We also include
experimental progress in mass delivery experiments, in-situ diagnostics and
hollow pellet fabrication, and emphasize new experimental possibilities for ELM
control based on hollow pellets. A related application is the disruption
mitigation scheme using powder encapsulated inside hollow shells. Further
experiments will also help to resolve known discrepancies between theoretical
predictions and experiments in using mass injection for ELM control and lead to
better predictive models for ELM stability and triggering.Comment: Manuscript prepared for reviews by {\it Nuclear Fusion}, following
the initial presentation in the 27th IAEA FEC, Gandhinagar, India, Oct. 22 -
27, 201
Position-sensitive detection of ultracold neutrons with an imaging camera and its implications to spectroscopy
Position-sensitive detection of ultracold neutrons (UCNs) is demonstrated
using an imaging charge-coupled device (CCD) camera. A spatial resolution less
than 15 m has been achieved, which is equivalent to an UCN energy
resolution below 2 pico-electron-volts through the relation . Here, the symbols , , and are the
energy resolution, the spatial resolution, the neutron rest mass and the
gravitational acceleration, respectively. A multilayer surface convertor
described previously is used to capture UCNs and then emits visible light for
CCD imaging. Particle identification and noise rejection are discussed through
the use of light intensity profile analysis. This method allows different types
of UCN spectroscopy and other applications.Comment: 12 figures, 28 pages, accepted for publication in NIM
Immunohistochemical detection of macrophage migration inhibitory factor in fetal and adult bovine epididymis: Release by the apocrine secretion mode?
Originally defined as a lymphokine inhibiting the random migration of macrophages, the macrophage migration inhibitory factor (MIF) is an important mediator of the host response to infection. Beyond its function as a classical cytokine, MIF is currently portrayed as a multifunctional protein with growth-regulating properties present in organ systems beyond immune cells. In previous studies, we detected substantial amounts of MIF in the rat epididymis and epididymal spermatozoa, where it appears to play a role during post-testicular sperm maturation and the acquisition of fertilization ability. To explore its presence in other species not yet examined in this respect, we extended the range of studies to the bull. Using a polyclonal antibody raised against MIF purified from bovine eye lenses, we detected MIF in the epithelium of the adult bovine epididymis with the basal cells representing a prominently stained cell type. A distinct accumulation of MIF at the apical cell pole of the epithelial cells and in membranous vesicles localized in the lumen of the epididynnal duct was obvious. In the fetal bovine epididymis, we also detected MIF in the epithelium, whereas MIF accumulation was evident at the apical cell surface and in apical protrusions. By immuno-electron microscopy of the adult bovine epididymis, we localized MIF in apical protrusions of the epithelial cells and in luminal membrane-bound vesicles that were found in close proximity to sperm cells. Although the precise origin of the MIF-containing vesicles remains to be delineated, our morphological observations support the hypothesis that they become detached from the apical surface of the epididymal epithelial cells. Additionally, an association of MIF with the outer dense fibers of luminal spermatozoa was demonstrated. Data obtained in this study suggest MIF release by an apocrine secretion mode in the bovine epididymis. Furthermore, MIF localized in the basal cells of the epithelium and in the connective tissue could be responsible for regulating the migration of macrophages in order to avoid contact of immune cells with spermatozoa that carry a wide range of potent antigens. Copyright (c) 2006 S. Karger AG, Basel
Measurement of the neutron lifetime using an asymmetric magneto- gravitational trap and in situ detection
The precise value of the mean neutron lifetime, , plays an important
role in nuclear and particle physics and cosmology. It is a key input for
predicting the ratio of protons to helium atoms in the primordial universe and
is used to search for new physics beyond the Standard Model of particle
physics. There is a 3.9 standard deviation discrepancy between
measured by counting the decay rate of free neutrons in a beam (887.7 2.2
s) and by counting surviving ultracold neutrons stored for different storage
times in a material trap (878.50.8 s). The experiment described here
eliminates loss mechanisms present in previous trap experiments by levitating
polarized ultracold neutrons above the surface of an asymmetric storage trap
using a repulsive magnetic field gradient so that the stored neutrons do not
interact with material trap walls and neutrons in quasi-stable orbits rapidly
exit the trap. As a result of this approach and the use of a new in situ
neutron detector, the lifetime reported here (877.7 0.7 (stat) +0.4/-0.2
(sys) s) is the first modern measurement of that does not require
corrections larger than the quoted uncertainties.Comment: 9 pages, 3 figures, 2 table
Implementation of routine outcome measurement in child and adolescent mental health services in the United Kingdom: a critical perspective
The aim of this commentary is to provide an overview of clinical outcome measures that are currently recommended for use in UK Child and Adolescent Mental Health Services (CAMHS), focusing on measures that are applicable across a wide range of conditions with established validity and reliability, or innovative in their design. We also provide an overview of the barriers and drivers to the use of Routine Outcome Measurement (ROM) in clinical practice
A boron-coated CCD camera for direct detection of Ultracold Neutrons (UCN)
A new boron-coated CCD camera is described for direct detection of ultracold
neutrons (UCN) through the capture reactions B
(n,0)Li (6%) and B(n,1)Li (94%).
The experiments, which extend earlier works using a boron-coated ZnS:Ag
scintillator, are based on direct detections of the neutron-capture byproducts
in silicon. The high position resolution, energy resolution and particle ID
performance of a scientific CCD allows for observation and identification of
all the byproducts , Li and (electron recoils). A
signal-to-noise improvement on the order of 10 over the indirect method has
been achieved. Sub-pixel position resolution of a few microns is demonstrated.
The technology can also be used to build UCN detectors with an area on the
order of 1 m. The combination of micrometer scale spatial resolution, few
electrons ionization thresholds and large area paves the way to new research
avenues including quantum physics of UCN and high-resolution neutron imaging
and spectroscopy.Comment: 10 pages, 8 figure
Status of the UCNτ experiment
The neutron is the simplest nuclear system that can be used to probe the structure of the weak interaction and search for physics beyond the standard model. Measurements of neutron lifetime and β-decay correlation coefficients with precisions of 0.02% and 0.1%, respectively, would allow for stringent constraints on new physics. The UCNτ experiment uses an asymmetric magneto-gravitational UCN trap with in situ counting of surviving neutrons to measure the neutron lifetime, τ_n = 877.7s (0.7s)_(stat) (+0.4/−0.2s)_(sys). We discuss the recent result from UCNτ, the status of ongoing data collection and analysis, and the path toward a 0.25 s measurement of the neutron lifetime with UCNτ
- …