23 research outputs found

    Label-free detection of myocardial ischaemia in the perfused rat heart by spontaneous Raman spectroscopy

    Get PDF
    Raman spectroscopy, which identifies intrinsic molecular constituents, has a potential for determining myocardial viability under label-free conditions. However, its suitability for evaluating myocardial ischaemia is undetermined. Focusing on cytochromes, i.e., representative molecules reflecting mitochondrial activity, we tested whether Raman spectroscopy is applicable for evaluating myocardial ischaemia especially during early ischaemic phase. We obtained spontaneous Raman spectra of the subepicardial myocardium in the Langendorff-perfused rat heart upon 532-nm excitation before and during the “stopped-flow,” global ischaemia. Semi-quantitative values of the peak intensities at 750 and 1127 cm−1, which reflect reduced cytochromes c and b, increased immediately and progressively after induction of the stopped flow, indicating progressive reduction of the mitochondrial respiration. Such spectral changes emerged before the loss of 1) mitochondrial membrane potentials measured by the fluorescence intensity of tetramethyl rhodamine ethyl ester or 2) staining of the triphenyl tetrazolium chloride dye in the myocardium. The progressive increases in the Raman peaks by stopped flow were significantly retarded by ischaemic preconditioning. Sequential measurements of the peak intensities at 750 and 1127 cm−1 enabled early detection of the myocardial ischaemia based on the mitochondrial functions. These data suggest that Raman spectroscopy offers the potential to evaluate acute ischaemic heart under label-free conditions

    Raman micro-spectroscopy as a viable tool to monitor and estimate the ionic transport in epithelial cells

    No full text
    The typical response to the lowering of plasma Na-vertical bar concentration and blood pressure in our body involves the release of aldosterone from the adrenal glands, which triggers the reabsorption of sodium in the kidney. Although the effects of aldosterone on this physiological mechanism were extensively studied in the past decades, there are still some aspects to be fully elucidated. In the present study, we propose for the first time a new approach based on Raman spectroscopy to monitor the ionic activity in aldosterone-treated A6 renal epithelial cells. This spectroscopic technique is capable of probing the cells through their thickness in a non-destructive and nimble way. The spectroscopic variations of the Raman bands associated to the O-H stretching of water were correlated to the variations of ionic concentration in the intracellular and extracellular fluids. The increase of Na+ concentration gradients was clearly visualized in the cytosol of aldosterone-treated cells. The enhancement of the Na+ current density induced by aldosterone was estimated from the variation of the ionic chemical potential across the intracellular space. In addition, the variation of the O-H Raman bands of water was used to quantify the cell thickness, which was not affected by aldosterone

    Fabrication of Three-Dimensionally Deformable Metal Structures Using Precision Electroforming

    No full text
    It is difficult to fabricate three-dimensional structures using semiconductor-process technology, because it is based on two-dimensional layered structure fabrication and the etching of thin films. In this study, we fabricated metal structures that can be dynamically deformed from two-dimensional to three-dimensional shapes by combining patterning using photolithography with electroforming technology. First, a resist structure was formed on a Cu substrate. Then, using a Ni sulfamate electroforming bath, a Ni structure was formed by electroforming the fabricated resist structure. Finally, the resist structure was removed to release the Ni structure fabricated on the substrate, and electroforming was used to Au-plate the entire surface. Scanning-electron microscopy revealed that the structure presented a high aspect ratio (thickness/resist width = 3.5), and metal structures could be fabricated without defects across the entire surface, including a high aspect ratio. The metallic structures had an average film thickness of 12.9 µm with σ = 0.49 µm, hardness of 600 HV, and slit width of 7.9 µm with σ = 0.25 µm. This microfabrication enables the fabrication of metal structures that deform dynamically in response to hydrodynamic forces in liquid and can be applied to fields such as environmental science, agriculture, and medicine

    Bioconjugation strategy for cell surface labelling with gold nanostructures designed for highly localized pH measurement

    Get PDF
    Understanding the pH changes at cell surfaces is important for understanding the mechanisms of different physiological processes. Here, the authors report on the development of a cell membrane anchored gold nanoparticle for surface enhanced Raman spectroscopy determination of pH
    corecore