379 research outputs found
Feasibility and performance of a device for automatic self-detection of symptomatic acute coronary artery occlusion in outpatients with coronary artery disease : a multicentre observational study
Background Time delay between onset of symptoms and seeking medical attention is a major determinant of mortality and morbidity in patients with acute coronary artery occlusion. Response time might be reduced by reliable self-detection. We aimed to formally assess the proof-of-concept and accuracy of self-detection of acute coronary artery occlusion by patients during daily life situations and during the very early stages of acute coronary artery occlusion.
Methods In this multicentre, observational study, we tested the operational feasibility, specificity, and sensitivity of our RELF method, a three-lead detection system with an automatic algorithm built into a mobile handheld device, for detection of acute coronary artery occlusion. Patients were recruited continuously by physician referrals from three Belgian hospitals until the desired sample size was achieved, had been discharged with planned elective percutaneous coronary intervention, and were able to use a smartphone; they were asked to perform random ambulatory selfrecordings for at least 1 week. A similar self-recording was made before percutaneous coronary intervention and at 60 s of balloon occlusion. Patients were clinically followed up until 1 month after discharge. We quantitatively assessed the operational feasibility with an automated dichotomous quality check of self-recordings. Performance was assessed by analysing the receiver operator characteristics of the ST difference vector magnitude. This trial is registered with ClinicalTrials.gov, number NCT02983396.
Findings From Nov 18, 2016, to April 25, 2018, we enrolled 64 patients into the study, of whom 59 (92%) were eligible for self-applications. 58 (91%) of 64 (95% CI 81.0-95.6) patients were able to perform ambulatory self-recordings. Of all 5011 self-recordings, 4567 (91%) were automatically classified as successful within 1 min. In 65 balloon occlusions, 63 index tests at 60 s of occlusion in 55 patients were available. The mean specificity of daily life recordings was 0.96 (0.95-0.97). The mean false positive rate during daily life conditions was 4.19% (95% CI 3.29-5.10). The sensitivity for the target conditions was 0.87 (55 of 63; 95% CI 0.77-0.93) for acute coronary artery occlusion, 0.95 (54 of 57; 0.86-0.98) for acute coronary artery occlusion with electrocardiogram (ECG) changes, and 1.00 (35 of 35) for acute coronary artery occlusion with ECG changes and ST-segment elevation myocardial infarction criteria (STEMI). The index test was more sensitive to detect a 60 s balloon occlusion than the STEMI criteria on 12-lead ECG (87% vs 56%; p<0.0001). The proportion of total variation in study estimates due to heterogeneity between patients (I-2) was low (12.6%). The area under the receiver operator characteristics curve was 0.973 (95% CI 0.956-0.990) for acute coronary artery occlusion at different cutoff values of the magnitude of the ST difference vector. No patients died during the study.
Interpretation Self-recording with our RELF device is feasible for most patients with coronary artery disease. The sensitivity and specificity for automatic detection of the earliest phase of acute coronary artery occlusion support the concept of our RELF device for patient empowerment to reduce delay and increase Survival without overloading emergency services. Copyright (C) 2019 The Author(s). Published by Elsevier Ltd
Full-length genome sequence of a simian immunodeficiency virus (SIV) infecting a captive agile mangabey (Cercocebus agilis) is closely related to SIVrcm infecting wild red-capped mangabeys (Cercocebus torquatus) in Cameroon
Simian immunodeficiency viruses (SIVs) are lentiviruses that infect an extensive number of wild African primate species. Here we describe for the first time SIV infection in a captive agile mangabey (Cercocebus agilis) from Cameroon. Phylogenetic analysis of the full-length genome sequence of SIVagi-00CM312 showed that this novel virus fell into the SIVrcm lineage and was most closely related to a newly characterized SIVrcm strain (SIVrcm-02CM8081) from a wild-caught red-capped mangabey (Cercocebus torquatus) from Cameroon. In contrast to red-capped mangabeys, no 24 bp deletion in CCR5 has been observed in the agile mangabey. Further studies on wild agile mangabeys are needed to determine whether agile and red-capped mangabeys are naturally infected with the same SIV lineage, or whether this agile mangabey became infected with an SIVrcm strain in captivity. However, our study shows that agile mangabeys are susceptible to SIV infection
Combining optimized image processing with dual axis rotational angiography : toward low-dose invasive coronary angiography
Background Dual axis rotational coronary angiography procedures. Methods and Results Twenty patients were examined using to 2.22 mSv in procedures, where the latter is further reduced to 1.79 mSv when excluding ventriculography. Conclusions During invasive coronary angiography, procedures, using 1 effective dose conversion factor of 0.30 mSvGy(-1)cm(-2) is feasible
Transveneuze versus subcutane defibrillator bij patiënten met hypertrofe cardio myopathie : een retrospectieve analyse in twee Belgische ziekenhuizen
Hypertrofe cardiomyopathie (HCM) is een erfelijke aandoening met een verhoogd risico op plotse dood (SCD). Er zijn geen gerandomiseerde studies om de implantatie van een implantable cardioverter-defibrillator (ICD) in patiënten met HCM te leiden. Aanbevelingen zijn gebaseerd op observationele, retrospectieve cohort studies
Different dynamics of new-onset electrocardiographic changes after balloon- and self-expandable transcatheter aortic valve replacement : implications for prolonged heart rhythm monitoring
Background: Newonset electrocardiographic (ECG) changes after transcatheter aortic valve replacement (TAVR) are used to assess the risk for late atrioventricular block. However, the time of ECG evaluation remains controversial. We aimed to compare the time course and dynamics of newonset ECG changes according to valve design in balloon- (BEV) and self-expandable (SEV) TAVR.
Methods and results: This single center study enrolled 133 consecutive TAVR patients (28.6% SEV, 71.4% BEV). Patients with pre-existent permanent pacemaker implant (PPMI), procedural death or incomplete ECG registration were excluded. Standard 12-lead ECG was performed before the procedure, at 1, 24, 48 and 120 h and 1 month. In BEV patients, no significant PR prolongation occurred, whereas in SEV patients the PR interval prolonged significantly with 33.7 +/- 22.0 ms (p 24 h after TAVR) was higher in SEV compared to BEV patients (15.3% versus 1.5%, p= 0.008).
Conclusion: Self-expandable valves cause more impairment in atrioventricular conduction with a delayed time course compared to balloon expandable valves. This might explain the higher pacemaker need beyond 24 h after TAVR. Our findings suggest that patients with self-expandable valves require at least 48 h ECG monitoring post TAVR. (c) 2020 Published by Elsevier Inc
Left ventricular scar and the acute hemodynamic effects of multivein and multipolar pacing in cardiac resynchronization
Background We sought to determine whether presence, amount and distribution of scar impacts the degree of acute hemodynamic response (AHR) with multisite pacing. Multi-vein pacing (MVP) or multipolar pacing (MPP) with a multi-electrode left ventricular (LV) lead may offer benefits over conventional biventricular pacing in patients with myocardial scar. Methods In this multi-center study left bundle branch block patients underwent an hemodynamic pacing study measuring LV dP/dtmax. Patients had cardiac magnetic resonance scar imaging to assess the effect of scar presence, amount and distribution on AHR. Results 24 patients (QRS 171 ± 20 ms) completed the study (83% male). An ischemic etiology was present in 58% and the mean scar volume was 6.0 ± 7.0%. Overall discounting scar, MPP and MVP showed no significant AHR increase compared to an optimized “best BiV” (BestBiV) site. In a minority of patients (6/24) receiver-operator characteristic analysis of scar volume (cut off 8.48%) predicted a small AHR improvement with MPP (sensitivity 83%, specificity 94%) but not MVP. Patients with scar volume > 8.48% had a MPP-BestBiV of 3 ± 6.3% vs. −6.4 ± 7.7% for those below the cutoff. There was a significant correlation between the difference in AHR and scar volume for MPP-BestBiV (R = 0.49, p = 0.02) but not MVP-BestBiV(R = 0.111, p = 0.62). The multielectrode lead positioned in scar predicted MPP AHR improvement (p = 0.04). Conclusions Multisite pacing with MPP and MVP shows no AHR benefit in all-comers compared to optimized BestBiV pacing. There was a minority of patients with significant scar volume in relation to the LV site that exhibited a small AHR improvement with MPP
- …