67 research outputs found

    ATLAS monitored drift tube chambers for super-LHC

    Get PDF
    After the high-luminosity upgrade of the Large Hadron Collider (LHC) at CERN, the ATLAS muon spectrometer is expected to work at 10 times increased background rates of gammas and neutrons. This is challenging as the momentum resolution of the spectrometer is expected to be 10 %. This requires a single tube resolution of the muon drift tubes of 80 mum. At background rates around 1000 Hz/cm2 space charge effects will lead in the slow and non-linear AR:CO2 = 93:7 gas mixture to a degradation of the drift-tube spatial resolution. This was studied before experimentally for gammas and low energetic neutrons. Almost no information exists for fast neutrons. Therefore, we organized our studies under the following aspects: - We investigated the influence of 11 MeV neutrons on the position resolution of ATLAS MDT chambers. At flux densities between 4 and 16 kHz/cm2, almost no influence on the position resolution was found, it degrades by only 10 mum at a detection efficiency of only 4*10-4. - We investigated inert gas mixtures on fastness and linearity of their position-drifttime (r-t) relation. At a reduction of the maximum drift time by a factor of 2, the use of the present hardware and electronics might be possible. For our experimental studies we used our Munich cosmic ray facility. Two gas mixtures show almost identical position resolution as the standard gas. - For spectrometer regions of highest background rates we contributed to the investigation of newly developed 15 mm drift tubes. Position resolutions have been measured as a function of gamma background rates between 0 and 1400 Hz/cm2. - Garfield simulations have been performed to simulate space charge effects due to gamma irradiation. Results will be presented for the standard geometry as well as for the new 15 mm drift tubes.Comment: 3 pages, 7 figures, conferenc

    High Rate Proton Irradiation of 15mm Muon Drifttubes

    Get PDF
    Future LHC luminosity upgrades will significantly increase the amount of background hits from photons, neutrons and protons in the detectors of the ATLAS muon spectrometer. At the proposed LHC peak luminosity of 5*10^34 1/cm^2s, background hit rates of more than 10 kHz/cm^2 are expected in the innermost forward region, leading to a loss of performance of the current tracking chambers. Based on the ATLAS Monitored Drift Tube chambers, a new high rate capable drift tube detecor using tubes with a reduced diameter of 15mm was developed. To test the response to highly ionizing particles, a prototype chamber of 46 15mm drift tubes was irradiated with a 20 MeV proton beam at the tandem accelerator at the Maier-Leibnitz Laboratory, Munich. Three tubes in a planar layer were irradiated while all other tubes were used for reconstruction of cosmic muon tracks through irradiated and non-irradiated parts of the chamber. To determine the rate capability of the 15mm drift-tubes we investigated the effect of the proton hit rate on pulse height, efficiency and spatial resolution of the cosmic muon signals

    High-Rate Capable Floating Strip Micromegas

    Get PDF
    We report on the optimization of discharge insensitive floating strip Micromegas (MICRO-MEsh GASeous) detectors, fit for use in high-energy muon spectrometers. The suitability of these detectors for particle tracking is shown in high-background environments and at very high particle fluxes up to 60MHz/cm2^2. Measurement and simulation of the microscopic discharge behavior have demonstrated the excellent discharge tolerance. A floating strip Micromegas with an active area of 48cm×\times50cm with 1920 copper anode strips exhibits in 120GeV pion beams a spatial resolution of 50μ\mum at detection efficiencies above 95%. Pulse height, spatial resolution and detection efficiency are homogeneous over the detector. Reconstruction of particle track inclination in a single detector plane is discussed, optimum angular resolutions below 55^\circ are observed. Systematic deviations of this μ\muTPC-method are fully understood. The reconstruction capabilities for minimum ionizing muons are investigated in a 6.4cm×\times6.4cm floating strip Micromegas under intense background irradiation of the whole active area with 20MeV protons at a rate of 550kHz. The spatial resolution for muons is not distorted by space charge effects. A 6.4cm×\times6.4cm floating strip Micromegas doublet with low material budget is investigated in highly ionizing proton and carbon ion beams at particle rates between 2MHz and 2GHz. Stable operation up to the highest rates is observed, spatial resolution, detection efficiencies, the multi-hit and high-rate capability are discussed.Comment: Presented at ICHEP 2014, accepted for publication in Nuclear Physics B Proceedings Supplement

    Performance of Drift-Tube Detectors at High Counting Rates for High-Luminosity LHC Upgrades

    Full text link
    The performance of pressurized drift-tube detectors at very high background rates has been studied at the Gamma Irradiation Facility (GIF) at CERN and in an intense 20 MeV proton beam at the Munich Van-der-Graaf tandem accelerator for applications in large-area precision muon tracking at high-luminosity upgrades of the Large Hadron Collider (LHC). The ATLAS muon drifttube (MDT) chambers with 30 mm tube diameter have been designed to cope with and neutron background hit rates of up to 500 Hz/square cm. Background rates of up to 14 kHz/square cm are expected at LHC upgrades. The test results with standard MDT readout electronics show that the reduction of the drift-tube diameter to 15 mm, while leaving the operating parameters unchanged, vastly increases the rate capability well beyond the requirements. The development of new small-diameter muon drift-tube (sMDT) chambers for LHC upgrades is completed. Further improvements of tracking efficiency and spatial resolution at high counting rates will be achieved with upgraded readout electronics employing improved signal shaping for high counting rates

    Could the GSI Oscillations be Observed in a Standard Electron Capture Decay Experiment?

    Get PDF
    The electron-capture decay of 180Re has been investigated to search for oscillations in the decay probability as reported from a recent measurement at GSI, Darmstadt. The production period was kept short compared to the reported oscillation period. No such oscillation was observed, indicating that the reported oscillations would not have been observable in a conventional experiment with radioactive atoms in a solid environment but must have to do with the unique conditions in the GSI experiment where hydrogen-like ions are moving independently in a storage ring and decaying directly by a true two-body decay to a long-lived (ground-) state. Our finding could restrict possible theoretical interpretations of the oscillations.Comment: 6 pages, 4 figure

    A gas analyzer for the internal polarized target of the HERMES experiment

    Get PDF
    A gas analyzer has been developed for the internal polarized target of the HERMES experiment at DESY in order to determine the relative amount of atomic and molecular hydrogen or deuterium in a gas sample. The precise quantitative knowledge of this ratio is crucial because the nucleons in atoms and molecules contribute differently to the average nuclear polarization of the target gas. A new calibration technique used to derive the relative sensitivity to atoms and molecules is presented. As an example, it is shown how the gas analyzer is used within the HERMES environment to divide the molecules in the gas sample into an unpolarized and a potentially polarized fraction
    corecore