2,333 research outputs found

    Calibration of a two-phase xenon time projection chamber with a 37^{37}Ar source

    Full text link
    We calibrate a two-phase xenon detector at 0.27 keV in the charge channel and at 2.8 keV in both the light and charge channels using a 37^{37}Ar source that is directly released into the detector. We map the light and charge yields as a function of electric drift field. For the 2.8 keV peak, we calculate the Thomas-Imel box parameter for recombination and determine its dependence on drift field. For the same peak, we achieve an energy resolution, Eσ/EmeanE_{\sigma}/E_{mean}, between 9.8% and 10.8% for 0.1 kV/cm to 2 kV/cm electric drift fields.Comment: 12 pages, 7 figure

    The magnetoelectrochemical switch

    Get PDF
    In the field of spintronics, the archetype solid-state two-terminal device is the spin valve, where the resistance is controlled by the magnetization configuration. We show here how this concept of spin-dependent switch can be extended to magnetic electrodes in solution, by magnetic control of their chemical environment. Appropriate nanoscale design allows a huge enhancement of the magnetic force field experienced by paramagnetic molecular species in solutions, which changes between repulsive and attractive on changing the electrodes' magnetic orientations. Specifically, the field gradient force created within a sub-100-nm-sized nanogap separating two magnetic electrodes can be reversed by changing the orientation of the electrodes' magnetization relative to the current flowing between the electrodes. This can result in a breaking or making of an electric nanocontact, with a change of resistance by a factor of up to 103. The results reveal how an external field can impact chemical equilibrium in the vicinity of nanoscale magnetic circuits

    Fermilab Neutron Therapy Facility / Neutron Spectrum Determination By Threshold Foils

    Get PDF
    oS(FNDA2006)041 © Copyright owned by the author(s) under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike Licence

    Conductance of Distorted Carbon Nanotubes

    Full text link
    We have calculated the effects of structural distortions of armchair carbon nanotubes on their electrical transport properties. We found that the bending of the nanotubes decreases their transmission function in certain energy ranges and leads to an increased electrical resistance. Electronic structure calculations show that these energy ranges contain localized states with significant σ\sigma-π\pi hybridization resulting from the increased curvature produced by bending. Our calculations of the contact resistance show that the large contact resistances observed for SWNTs are likely due to the weak coupling of the NT to the metal in side bonded NT-metal configurations.Comment: 5 pages RevTeX including 4 figures, submitted to PR

    General-Relativistic Thomas-Fermi model

    Get PDF
    A system of self-gravitating massive fermions is studied in the framework of the general-relativistic Thomas-Fermi model. We study the properties of the free energy functional and its relation to Einstein's field equations. A self-gravitating fermion gas we then describe by a set of Thomas-Fermi type self-consistency equations.Comment: 7 pages, LaTex, to appear in Gen. Rel. Gra

    Practicing Emotionally Biased Retrieval Affects Mood and Establishes Biased Recall a Week Later

    Get PDF
    Cognitive Bias Modification (CBM) can yield clinically relevant results. Only few studies have directly manipulated memory bias, which is prominent in depression. In a new approach to CBM, we sought to simulate or oppose ruminative processes by training the retrieval of negative or positive words. Participants studied positive and negative word pairs (Swahili cues with Dutch translations). In the positive and negative conditions, each of the three study trials was followed by a cued-recall test of training-congruent translations; a no-practice condition merely studied the pairs. Recall of the translations was tested after the training and after 1 week. Both recall tests revealed evidence of training-congruent bias and bias was associated with emotional autobiographical memory. Positive retrieval practice yielded stable positive mood, in contrast to the other conditions. The results indicate that memory bias can be established through retrieval practice and that the bias transfers to mood and autobiographical memory

    The Cost of Costing Treatments Incorrectly: Errors in the Application of Drug Prices in Economic Evaluation Due to Failing to Account for the Distribution of Patient Weight

    Get PDF
    AbstractBackgroundThe cost of pharmaceuticals dosed by weight or body surface area (BSA) can be estimated in several ways for economic evaluations. A review of 20 recent National Institute for Health and Care Excellence appraisals showed that 17 of them took the mean weight or BSA of patients, 2 costed the individual patient data from trials, and 2 fitted a distribution to patient-level data.ObjectivesTo investigate the estimated drug costs using different methodologies to account for patient characteristics for pharmaceuticals with a weight- or BSA-based posology. The secondary objective was to explore the suitability of general population data as a proxy for patient-level data.MethodsPatient-level data were pooled from three clinical trials and used to calculate a hypothetical cost per administration of eight licensed pharmaceuticals, applying the three methods used in recent National Institute for Health and Care Excellence appraisals. The same analysis was performed using data from the Health Survey for England (in place of patient-level data) to investigate the validity of using general population data as a substitute for patient-level data.ResultsCompared with using patient-level data from clinical trials, the mean patient characteristics (weight or BSA) led to an underestimation of drug cost by 6.1% (range +1.5% to −25.5%). Fitting a distribution to patient-level data led to a mean difference of +0.04%. All estimates were consistent using general population data.ConclusionsEstimation of drug costs in health economic evaluation should account for the distribution in weight or BSA to produce accurate results. When patient data are not available, general population data may be used as an alternative
    • …
    corecore