1,491 research outputs found

    Audio mixing in a tri-port nano-electro-mechanical device

    Full text link
    We report on experiments performed on a cantilever-based tri-port nano-electro-mechanical (NEMS) device. Two ports are used for actuation and detection through the magnetomotive scheme, while the third port is a capacitively coupled gate electrode. By applying a low frequency voltage signal on the gate, we demonstrate mixing in the mechanical response of the device, even for {\it low magnetomotive drives, without resorting to conduction measurements through the NEMS}. The technique can thus be used in particular in the linear regime, as an alternative to nonlinear mixing, for normal conducting devices. An analytic theory is presented reproducing the data without free parameter

    DSM-V: modifying the postpartum-onset specifier to include hypomania

    Get PDF
    By failing to include it under the rubric of the postpartum-onset specifier, Diagnostic and Statistical Manual of Mental Disorders (DSM)-IV-TR has ignored the clinical reality that childbirth is a potent trigger of hypomania. Given the serious and occasionally tragic consequences of misdiagnosis of bipolar II depression as unipolar depression in the postpartum period, it is argued that DSM-V should consider modifying the postpartum-onset specifier to include episodes of hypomania

    Impact of Scottish vocational qualifications on residential child care : have they fulfilled the promise?

    Get PDF
    This article will present findings from a doctoral study exploring the impact of 'SVQ Care: Promoting Independence (level III)' within children's homes. The study focuses on the extent to which SVQs enhance practice and their function within a 'learning society'. A total of 30 staff were selected from seven children's homes in two different local authority social work departments in Scotland. Each member of staff was interviewed on four separate occasions over a period of 9 months. Interviews were structured using a combination of repertory grids and questions. Particular focus was given to the assessment process, the extent to which SVQs enhance practice and the learning experiences of staff. The findings suggest that there are considerable deficiencies both in terms of the SVQ format and the way in which children's homes are structured for the assessment of competence. Rather than address the history of failure within residential care, it appears that SVQs have enabled the status quo to be maintained whilst creating an 'illusion' of change within a learning society

    Measurement of 222Rn dissolved in water at the Sudbury Neutrino Observatory

    Full text link
    The technique used at the Sudbury Neutrino Observatory (SNO) to measure the concentration of 222Rn in water is described. Water from the SNO detector is passed through a vacuum degasser (in the light water system) or a membrane contact degasser (in the heavy water system) where dissolved gases, including radon, are liberated. The degasser is connected to a vacuum system which collects the radon on a cold trap and removes most other gases, such as water vapor and nitrogen. After roughly 0.5 tonnes of H2O or 6 tonnes of D2O have been sampled, the accumulated radon is transferred to a Lucas cell. The cell is mounted on a photomultiplier tube which detects the alpha particles from the decay of 222Rn and its daughters. The overall degassing and concentration efficiency is about 38% and the single-alpha counting efficiency is approximately 75%. The sensitivity of the radon assay system for D2O is equivalent to ~3 E(-15) g U/g water. The radon concentration in both the H2O and D2O is sufficiently low that the rate of background events from U-chain elements is a small fraction of the interaction rate of solar neutrinos by the neutral current reaction.Comment: 14 pages, 6 figures; v2 has very minor change

    A radium assay technique using hydrous titanium oxide adsorbent for the Sudbury Neutrino Observatory

    Full text link
    As photodisintegration of deuterons mimics the disintegration of deuterons by neutrinos, the accurate measurement of the radioactivity from thorium and uranium decay chains in the heavy water in the Sudbury Neutrino Observatory (SNO) is essential for the determination of the total solar neutrino flux. A radium assay technique of the required sensitivity is described that uses hydrous titanium oxide adsorbent on a filtration membrane together with a beta-alpha delayed coincidence counting system. For a 200 tonne assay the detection limit for 232Th is a concentration of 3 x 10^(-16) g Th/g water and for 238U of 3 x 10^(-16) g U/g water. Results of assays of both the heavy and light water carried out during the first two years of data collection of SNO are presented.Comment: 12 pages, 4 figure

    Measurement of the rate of nu_e + d --> p + p + e^- interactions produced by 8B solar neutrinos at the Sudbury Neutrino Observatory

    Get PDF
    Solar neutrinos from the decay of 8^8B have been detected at the Sudbury Neutrino Observatory (SNO) via the charged current (CC) reaction on deuterium and by the elastic scattering (ES) of electrons. The CC reaction is sensitive exclusively to nu_e's, while the ES reaction also has a small sensitivity to nu_mu's and nu_tau's. The flux of nu_e's from ^8B decay measured by the CC reaction rate is \phi^CC(nu_e) = 1.75 +/- 0.07 (stat)+0.12/-0.11 (sys.) +/- 0.05(theor) x 10^6 /cm^2 s. Assuming no flavor transformation, the flux inferred from the ES reaction rate is \phi^ES(nu_x) = 2.39+/-0.34 (stat.)+0.16}/-0.14 (sys) x 10^6 /cm^2 s. Comparison of \phi^CC(nu_e) to the Super-Kamiokande Collaboration's precision value of \phi^ES(\nu_x) yields a 3.3 sigma difference, providing evidence that there is a non-electron flavor active neutrino component in the solar flux. The total flux of active ^8B neutrinos is thus determined to be 5.44 +/-0.99 x 10^6/cm^2 s, in close agreement with the predictions of solar models.Comment: 6 pages (LaTex), 3 figures, submitted to Phys. Rev. Letter
    corecore