9 research outputs found

    Impact of chronic obstructive pulmonary disease and dyspnoea on clinical outcomes in ticagrelor treated patients undergoing percutaneous coronary intervention in the randomized GLOBAL LEADERS trial

    Get PDF
    AIMS: To evaluate long-term safety and efficacy of ticagrelor monotherapy in patients undergoing percutaneous coronary interventions (PCIs) in relation to chronic obstructive pulmonary disease (COPD) at baseline and the occurrence of dyspnoea reported as adverse event (AE) that may lead to treatment non-adherence. METHODS AND RESULTS: This is a non-prespecified, post hoc analysis of the randomized GLOBAL LEADERS trial (n = 15 991), comparing the experimental strategy of 23-month ticagrelor monotherapy following 1-mo

    Rationale and design of the EXAMINATION trial: A randomised comparison between everolimus-eluting stents and cobalt-chromium bare-metal stents in ST-elevation myocardial infarction

    No full text
    Aims: To assess the performance of the everolimus-eluting stent (EES) versus cobalt chromium bare-metal stent (BMS) in the setting of primary percutaneous coronary intervention for treatment of patients presenting with ST-segment elevation myocardial infarction (STEMI). The implantation of a drug-eluting stent in the setting of an acute myocardial infarction is still controversial. In several registries this clinical scenario has been associated with the development of stent thrombosis. The EES has demonstrated to reduce the stent thrombosis rate as compared to paclitaxel-eluting stent in randomised controlled trials, mainly performed in patients in stable clinical conditions. There are however few data regarding the effectiveness of EES in the context of STEMI. Methods and results: This is an investigator-driven, prospective, multicentre, multinational, randomised, single blind, two-arm, controlled trial (ClinicalTrials.gov number: NCT00828087). This trial, with an all comer design, randomises approximately 1,500 patients 1:1 to EES or BMS. Overall, any patient presenting with STEMI up to 48 hours who requires emergent percutaneous coronary intervention can be included. The primary endpoint is the patient-oriented combined endpoint of all-cause death, any myocardial infarction and any revascularisation at 1-year according to the Academic Research Consortium. Clinical follow-up will be scheduled at 30 days, six months, one year and yearly up to five years. No angiographic follow-up is mandated per protocol. Conclusions: This trial with broad inclusion and few exclusion criteria will shed light on the performance of the second generation EES in the complex scenario of STEMI

    Temporal Trends, Characteristics, and Outcomes of Infective Endocarditis After Transcatheter Aortic Valve Replacement.

    No full text
    Procedural improvements combined with the contemporary clinical profile of patients undergoing transcatheter aortic valve replacement (TAVR) may have influenced the incidence and outcomes of infective endocarditis (IE) following TAVR. We aimed to determine the temporal trends, characteristics, and outcomes of IE post-TAVR. Observational study including 552 patients presenting definite IE post-TAVR. Patients were divided in 2 groups according to the timing of TAVR (historical cohort [HC]: before 2014; contemporary cohort [CC]: after 2014). Overall incidence rates of IE were similar in both cohorts (CC vs HC: 5.45 vs 6.52 per 1000 person-years; P = .12), but the rate of early IE was lower in the CC (2.29‰ vs 4.89‰, P < .001). Enterococci were the most frequent microorganism. Most patients presented complicated IE ( CC: 67.7%; HC: 69.6%; P = .66), but the rate of surgical treatment remained low (CC: 20.7%; HC: 17.3%; P = .32). The CC exhibited lower rates of in-hospital acute kidney injury (35.1% vs 44.6%; P = .036) and in-hospital (26.6% vs 36.4%; P = .016) and 1-year (37.8% vs 53.5%; P < .001) mortality. Higher logistic EuroScore, Staphylococcus aureus etiology, and complications (stroke, heart failure, and acute renal failure) were associated with in-hospital mortality in multivariable analyses (P < .05 for all). Although overall IE incidence has remained stable, the incidence of early IE has declined in recent years. The microorganism, high rate of complications, and very low rate of surgical treatment remained similar. In-hospital and 1-year mortality rates were high but progressively decreased over time

    Infective Endocarditis Caused by Staphylococcus aureus After Transcatheter Aortic Valve Replacement.

    No full text
    BACKGROUND Staphylococcus aureus (SA) has been extensively studied as causative microorganism of surgical prosthetic-valve infective endocarditis (IE). However, scarce evidence exists on SA IE after transcatheter aortic valve replacement (TAVR). METHODS Data were obtained from the Infectious Endocarditis After TAVR International Registry, including patients with definite IE after TAVR from 59 centres in 11 countries. Patients were divided into 2 groups according to microbiologic etiology: non-SA IE vs SA IE. RESULTS SA IE was identified in 141 patients out of 573 (24.6%), methicillin-sensitive S aureus in most cases (115/141, 81.6%). Self-expanding valves were more common than balloon-expandable valves in patients with early SA IE. Major bleeding and sepsis complicating TAVR, neurologic symptoms or systemic embolism at admission, and IE with cardiac device involvement other than the TAVR prosthesis were associated with SA IE (P < 0.05 for all). Among post-TAVR patients with IE, the likelihood of SA IE increased from 19% in the absence of those risk factors to 84.6% if ≥ 3 risk factors were present. In-hospital (47.8% vs 26.9%; P < 0.001) and 2-year (71.5% vs 49.6%; P < 0.001) mortality rates were higher among patients with SA IE vs non-SA IE. Surgery at the time of index SA IE was associated with a lower mortality rate at follow-up (adjusted hazard ratio 0.46, 95% CI 0.22-0.96; P = 0.038). CONCLUSIONS SA IE represented approximately 25% of IE cases after TAVR and was associated with very high in-hospital and late mortality. The presence of some features determined a higher likelihood of SA IE and could help to orientate early antibiotic regimen selection. Surgery at index SA IE was associated with improved outcomes, and its role should be evaluated in future studies

    Mitral Valve Infective Endocarditis after Trans-Catheter Aortic Valve Implantation.

    No full text
    Scarce data exist on mitral valve (MV) infective endocarditis (IE) after transcatheter aortic valve implantation (TAVI). This multicenter study included a total of 579 patients with a diagnosis of definite IE after TAVI from the IE after TAVI International Registry and aimed to evaluate the incidence, characteristics, management, and outcomes of MV-IE after TAVI. A total of 86 patients (14.9%) had MV-IE. These patients were compared with 284 patients (49.1%) with involvement of the transcatheter heart valve (THV) only. Two factors were found to be associated with MV-IE: the use of self-expanding valves (adjusted odds ratio 2.49, 95% confidence interval [CI] 1.23 to 5.07, p = 0.012), and the presence of an aortic regurgitation ≥2 at discharge (adjusted odds ratio 3.33; 95% CI 1.43 to 7.73, p <0.01). There were no differences in IE timing and causative microorganisms between groups, but surgical management was significantly lower in patients with MV-IE (6.0%, vs 21.6% in patients with THV-IE, p = 0.001). All-cause mortality rates at 2-year follow-up were high and similar between patients with MV-IE (51.4%, 95% CI 39.8 to 64.1) and patients with THV-IE (51.5%, 95% CI 45.4 to 58.0) (log-rank p = 0.295). The factors independently associated with increased mortality risk in patients with MV-IE were the occurrence of heart failure (adjusted p <0.001) and septic shock (adjusted p <0.01) during the index hospitalization. One of 6 IE episodes after TAVI is localized on the MV. The implantation of a self-expanding THV and the presence of an aortic regurgitation ≥2 at discharge were associated with MV-IE. Patients with MV-IE were rarely operated on and had a poor prognosis at 2-year follow-up

    Perivalvular Extension of Infective Endocarditis after Transcatheter Aortic Valve Replacement.

    No full text
    BACKGROUND Infective endocarditis (IE) following transcatheter aortic valve replacement (TAVR) has been associated with a dismal prognosis. However, scarce data exist on IE perivalvular extension (PEE) in such patients. METHODS This multicenter study included a total of 579 patients who had the diagnosis of definite IE at a median of 171 (53-421) days following TAVR. PEE was defined as the presence of an intracardiac abscess, pseudoaneurysm or fistula confirmed by transthoracic/transophageal echocardiography, computed tomography or peri-operative findings. RESULTS A total of 105 patients (18.1%) were diagnosed with PEE (perivalvular abscess, pseudoaneurysm, fistula, or a combination in 87, 7, 7, and 4 patients, respectively). A history of chronic kidney disease (ORadj: 2.08; 95% CI: [1.27-3.41], p=0.003) and IE secondary to coagulase-negative staphylococci (ORadj: 2.71; 95% CI: [1.57-4.69], p<0.001) was associated with an increased risk of PEE. Surgery was performed at index IE episode in 34 patients (32.4%) with PEE (vs. 15.2% in patients without PEE, p<0.001). In-hospital and 2-year mortality rates among PEE-IE patients were 36.5% and 69.4%, respectively. Factors independently associated with an increased mortality risk were the occurrence of other complications (stroke post-TAVR, acute renal failure, septic shock) and the lack of surgery at index IE hospitalization (padj<0.05 for all). CONCLUSION PEE occurred in about one fifth of IE post-TAVR patients, with the presence of coagulase-negative staphylococci and chronic kidney disease determining an increased risk. Patients with PEE-IE exhibited very high early and late mortality rates, and surgery during IE hospitalization seemed to be associated with better outcomes

    Temporal Trends, Characteristics, and Outcomes of Infective Endocarditis After Transcatheter Aortic Valve Replacement

    No full text
    BACKGROUND Procedural improvements combined with the contemporary clinical profile of patients undergoing transcatheter aortic valve replacement (TAVR) may have influenced the incidence and outcomes of infective endocarditis (IE) following TAVR. We aimed to determine the temporal trends, characteristics, and outcomes of IE post-TAVR. METHODS Observational study including 552 patients presenting definite IE post-TAVR. Patients were divided in 2 groups according to the timing of TAVR (historical cohort [HC]: before 2014; contemporary cohort [CC]: after 2014). RESULTS Overall incidence rates of IE were similar in both cohorts (CC vs HC: 5.45 vs 6.52 per 1000 person-years; P = .12), but the rate of early IE was lower in the CC (2.29‰ vs 4.89‰, P < .001). Enterococci were the most frequent microorganism. Most patients presented complicated IE ( CC: 67.7%; HC: 69.6%; P = .66), but the rate of surgical treatment remained low (CC: 20.7%; HC: 17.3%; P = .32). The CC exhibited lower rates of in-hospital acute kidney injury (35.1% vs 44.6%; P = .036) and in-hospital (26.6% vs 36.4%; P = .016) and 1-year (37.8% vs 53.5%; P < .001) mortality. Higher logistic EuroScore, Staphylococcus aureus etiology, and complications (stroke, heart failure, and acute renal failure) were associated with in-hospital mortality in multivariable analyses (P < .05 for all). CONCLUSIONS Although overall IE incidence has remained stable, the incidence of early IE has declined in recent years. The microorganism, high rate of complications, and very low rate of surgical treatment remained similar. In-hospital and 1-year mortality rates were high but progressively decreased over time

    Stroke Complicating Infective Endocarditis After Transcatheter Aortic Valve Replacement.

    No full text
    BACKGROUND Stroke is one of the most common and potentially disabling complications of infective endocarditis (IE). However, scarce data exist about stroke complicating IE after transcatheter aortic valve replacement (TAVR). OBJECTIVES The purpose of this study was to determine the incidence, risk factors, clinical characteristics, management, and outcomes of patients with definite IE after TAVR complicated by stroke during index IE hospitalization. METHODS Data from the Infectious Endocarditis after TAVR International Registry (including 569 patients who developed definite IE following TAVR from 59 centers in 11 countries) was analyzed. Patients were divided into two groups according to stroke occurrence during IE admission (stroke [S-IE] vs. no stroke [NS-IE]). RESULTS A total of 57 (10%) patients had a stroke during IE hospitalization, with no differences in causative microorganism between groups. S-IE patients exhibited higher rates of acute renal failure, systemic embolization, and persistent bacteremia (p 8 mm were associated with a higher risk of stroke during the index IE hospitalization (p 3 risk factors. S-IE patients had higher rates of in-hospital mortality (54.4% vs. 28.7%; p < 0.001) and overall mortality at 1 year (66.3% vs. 45.6%; p < 0.001). Surgical treatment was not associated with improved outcomes in S-IE patients (in-hospital mortality: 46.2% in surgical vs. 58.1% in no surgical treatment; p = 0.47). CONCLUSIONS Stroke occurred in 1 of 10 patients with IE post-TAVR. A history of stroke, short time between TAVR and IE, vegetation size, valve prosthesis type, and residual aortic regurgitation determined an increased risk. The occurrence of stroke was associated with increased in-hospital and 1-year mortality rates, and surgical treatment failed to improve clinical outcomes
    corecore