3,713 research outputs found

    The economic effects of exogenous fiscal shocks in Spain: a SVAR approach

    Get PDF
    This paper estimates the effects of exogenous fiscal policy shocks in Spain in a VAR framework. Government expenditure expansionary shocks are found to have positive effects on output in the short-term at the cost of higher inflation and public deficits and lower output in the medium and long term. Tax increases are found to drag economic activity in the medium term while entailing an only temporary improvement of the public budget balance. The application of these results to the analysis of fiscal policy in Spain since the mid-nineties points to the conclusion that the consolidation process does not seem to have involved costs in terms of output growth. Moreover, the stance of fiscal policy has become more counter-cyclical in that period. JEL Classification: E62, H30Fiscal multipliers, Fiscal shocks, VAR

    Evolución y algunos parámetros de la población invernante de Gaviota reidora (Larus ridibundus) en Madrid (España Central)

    Get PDF
    La població de gavina riallera que hiverna a Madrid ha augmentat contínuament des de 1980, i ha arribat al voltant de 70.000 individus a l'hivern de 1993. Aquest article examina les variacions diàries i mensuals en el nombre de gavines menjant en un gran abocador als afores de Madrid, al mateix temps que aporta dades sobre edats i sexes de la població hivernant. L'abocador es utilitzat principalment durant el matí i el migdia per femelles adultes

    Ladrillo cerámico con huecos hexagonales

    Get PDF
    Ladrillo cerámico con huecos hexagonales. La invención consiste en un ladrillo cerámico con huecos hexagonales a lo largo de su dirección longitudinal. Resuelve el problema de la transmisión de ruido aéreo que presentan los ladrillos cerámicos con hueco cuadrado o rectangular. La intensidad del sonido transmitido en sólidos decrece con el aumento de camino recorrido. Por ello, la sustitución de las paredes perpendiculares que definen los huecos cuadrados o rectangulares, por las que definen los huecos hexagonales representa un mayor recorrido y una absorción mayor de ruido. El espesor del ladrillo puede variar según contenga una o más filas de hexágonos compartiendo caras o vértices. No hay limitación en las dimensiones del largo y ancho del mismo. Exteriormente los cantos de las piezas pueden ser machihembrados y las caras planas pueden o no presentar estriado. La colocación de la pieza se realiza con los huecos paralelos a la horizontal. Utilización en construcción de paramentos verticales en edificio

    Revascularización carotídea con angioplastia y stent: resultados globales y comparación entre dispositivos de protección proximal y distal

    Full text link
    Tesis doctoral inédita leída en la Universidad Autónoma de Madrid, Facultad de Medicina, Departamento de Cirugía. Fecha de lectura: 5 de Noviembre de 201

    Modelado de sistemas de desecantes sólidos para el tratamiento de aire de ventilación en edificios

    Get PDF
    Se realiza un análisis de los sistemas de tratamiento de aire exterior de ventilación en edificios con desecantes sólidos. En edificios con elevadas ganancias internas y situados en ciudades con climas húmedos, los sistemas convencionales no pueden garantizar el confort térmico en la zona ya que no tienen un control de la humedad. Como solución a este problema, las unidades de tratamiento de aire con desecantes sólidos (UTA desecante) tratan la carga sensible y latente por separado, garantizando el confort térmico. Esta tesis realiza una serie de contribuciones en algunas de las líneas de investigación más importantes de las UTAs desecantes. En primer lugar, el control de la operación de las UTAs desecantes se basan en un control simple, no incluyen una inteligencia de control que permita optimizar el funcionamiento del sistema desde el punto de vista del consumo de energía y en función de las condiciones de operación. El primer artículo que avala esta tesis [1] realiza un estudio de un sistema de tratamiento de aire exterior complementado con un suelo radiante para el acondicionamiento de recintos de grandes volúmenes. La principal aportación es una estrategia de control óptima de la UTA desecante desde el punto de vista del consumo de energía, favoreciendo la contribución de energía solar en la regeneración de la rueda y comprobando que se satisfacen las condiciones de confort de los ocupantes de la zona. Comparándolo con un sistema convencional, se demuestra que el sistema desecante solar tiene un 35% menos de consumo de energía. En una fase posterior al primer artículo, se descubren nuevas investigaciones que demuestran que las condiciones de velocidad, temperatura y humedad del aire, condicionan el rendimiento de la rueda desecante. Esta afirmación pone en duda los resultados obtenidos con UTAs desecantes en los que el modelo de rueda es de efectividad constante. Para resolver este problema, en el segundo artículo que avala esta tesis [2] se analiza la influencia del modelo de rueda de efectividad variable en el rendimiento del sistema y en la capacidad de asegurar el confort en la zona, en función de la temperatura de regeneración y el caudal de aire. Se demuestra la necesidad de sustituir el modelo de rueda de efectividad constante por efectividad variable para garantizar la fiabilidad de los resultados. Además, la operación del sistema con caudales de aire muy bajos penaliza el rendimiento de la rueda en mayor medida que con bajas temperaturas de regeneración. Finalmente, con el objetivo de que en la actualidad los sistemas generadores de energía formen parte del propio edificio, en el tercer artículo que avala esta tesis [3] se propone un nuevo sistema de tratamiento de aire exterior de ventilación con desecantes sólidos, denominado sistema de fachada desecante, en el que se incorpora la fachada del edificio al sistema. El material desecante es introducido dentro de una fachada ventilada, formando dos capas de material desecante. El aire de ventilación circula a través de la cámara de aire de la fachada y se deshumecta en contacto con el desecante. A la salida, se introduce en una climatizadora convencional donde se somete a un tratamiento de enfriamiento para ser impulsado a la zona. La fachada incorpora un captador solar que calienta el aire exterior hasta la temperatura necesaria para su regeneración. Se valora el potencial del sistema en un clima húmedo y se calcula la eficiencia del sistema en función de las condiciones exteriores: radiación solar, humedad y temperatura. Se demuestra que la eficiencia del sistema depende fundamentalmente de la radiación solar incidente sobre la fachada. [1] The optimization of the operation of a solar desiccant air handling unit coupled with a radiant floor. José Manuel Cejudo López, Francisco Fernández Hernández, Fernando Domínguez Muñoz, Antonio Carrillo Andrés. Energy and Buildings 62 (2013) 427-435. [2] Influence of the desiccant wheel effectiveness method approaches, with fix and variable effectiveness parameters, on the performance results of an airport air-conditioning system. Celestino R. Ruivo, Francisco Fernández Hernández, José Manuel Cejudo López. Energy Conversion and Management 94 (2015) 458-471. [3] A new desiccant channel to be integrated in building façades. Francisco Fernández Hernández, José Manuel Cejudo López, Fernando Domínguez Muñoz, Antonio Carrillo Andrés. Energy and Buildings 86 (2015) 318-327

    pTNoC: Probabilistically time-analyzable tree-based NoC for mixed-criticality systems

    Get PDF
    The use of networks-on-chip (NoC) in real-time safety-critical multicore systems challenges deriving tight worst-case execution time (WCET) estimates. This is due to the complexities in tightly upper-bounding the contention in the access to the NoC among running tasks. Probabilistic Timing Analysis (PTA) is a powerful approach to derive WCET estimates on relatively complex processors. However, so far it has only been tested on small multicores comprising an on-chip bus as communication means, which intrinsically does not scale to high core counts. In this paper we propose pTNoC, a new tree-based NoC design compatible with PTA requirements and delivering scalability towards medium/large core counts. pTNoC provides tight WCET estimates by means of asymmetric bandwidth guarantees for mixed-criticality systems with negligible impact on average performance. Finally, our implementation results show the reduced area and power costs of the pTNoC.The research leading to these results has received funding from the European Community’s Seventh Framework Programme [FP7/2007-2013] under the PROXIMA Project (www.proxima-project.eu), grant agreement no 611085. This work has also been partially supported by the Spanish Ministry of Science and Innovation under grant TIN2015-65316-P and the HiPEAC Network of Excellence. Mladen Slijepcevic is funded by the Obra Social Fundación la Caixa under grant Doctorado “la Caixa” - Severo Ochoa. Carles Hern´andez is jointly funded by the Spanish Ministry of Economy and Competitiveness (MINECO) and FEDER funds through grant TIN2014-60404-JIN. Jaume Abella has been partially supported by the MINECO under Ramon y Cajal postdoctoral fellowship number RYC-2013-14717.Peer ReviewedPostprint (author's final draft

    Overconsolidated flysch-type clays. Engineering considerations for the Strait of Gibraltar tunnel project

    Get PDF
    The stress-strain behaviour of 85 overconsolidated clay samples from Campo de Gibraltar Flysch Through Domain (Algeciras Unit, South Spain) is presented and discussed. The samples were identified and classified following ASTM standards while their chemical and mineralogical composition were determined by chemical and X-ray techniques. Several samples were tested under triaxial as well as oedometric conditions. Given the results, a detailed comparison was made between different theoretical constitutive models and real testing data, using the finite-elements method. The comparison indicated a good fit between experimental data and those found with finite-elements modelling when the Hardening Soil constitutive model was used. This model showed a better fit than did the Modified Cam -Clay model (historically used for modelling clayey soils), although the latter fit proved better for lower strain values (<5%) than higher ones. These results clarify this intermediate material (hard soils - weak rocks) behaviour and will help in Strait of Gibraltar tunnel project design, as these materials are widely involved in this tunnel design.Sergeyco Andalucía S.L.SECEGS

    Structural and numerical identifiability of thermal resistances in plate fin-and-tube heat exchangers using manufacturer catalog data

    Get PDF
    Plate fin-and-tube heat exchangers, commonly known as heating/cooling coils, are widely used in HVAC systems to transfer heat to or from air. A problem of practical interest in coil simulation is to identify the thermal resistances on the air and liquid sides using manufacturer catalog data. Manufacturers rarely provide detailed information (geometry and circuitry) of the coils they sell or install in factory-made equipment such as air handling units or fan-coils; they just report the performance of the coil at a few typical operating conditions. This paper examines whether it is mathematically possible to back-calculate the thermal resistances on the air and liquid sides using a set of performance data that is disturbed by noise (e.g. measurement errors) and consists of operating cases in which none of the two thermal resistances can be neglected. The first part of the paper discusses the structural identifiability problem, that is, the mathematical possibility of fitting Nusselt-type correlations for air and liquid, as well as a constant resistance for the wall. The second part of the paper discusses the possibility of calculating the numerical value of the parameters of the Nusselt correlations (constant or constant and exponent) using noisy data. The analysis is applied to a typical coil, which is simulated by means of a mathematical modelUniversidad de Málaga. Campus de Excelencia Internacional Andalucía Tech
    corecore