1,535 research outputs found

    Survey of heat transfer to near critical fluids

    Get PDF
    Survey topics include - heat transfer boundaries of near critical region, free, natural, and forced convection experiments, oscillations, geometric effects, parameters which appear to be significant to heat transfer in critical region, and theories which have been proposed for region

    The dryout region in frictionally heated sliding contacts

    Get PDF
    Some conditions under which boiling and two-phase flow can occur in or near a wet sliding contact are determined and illustrated. The experimental apparatus consisted of a tool pressed against an instrumented slider plate and motion picture sequences at 4000 frames/sec. The temperature and photographic data demonstrated surface conditions of boiling, drying, trapped gas evolution (solutions), and volatility of fluid mixture components. The theoretical modeling and analysis are in reasonable agreement with experimental data

    Trends in the Ohio Dairy Industry During the Period, 1924 to 1944

    Get PDF

    The specialist breast care nurse's role in the identification and minimisation of distress in a members' only, breast cancer focused online support community

    Get PDF
    Objectives: To show how a specialist breast care nurse (SBCN) can use the distress thermometer to determine an online community member’s distress level and then use the information in their posts and blogs to identify the cause(s) and deal with them appropriately. To highlight the use of a structured written emotional expression (SWEE) format online, as a way of minimising distress. Method: A survey of online community members together with analysis of the content of members’ posts and blogs to determine whether their distress thermometer score had decreased since the SBCN had been online to deal with member distress. Results: The survey showed that four of the survey participants who completed the survey N=30 had completed a SWEE, been personal messaged by the SBCN about their distress thermometer score and declared that the information and advice they received had been instrumental in decreasing their distress score. It was not possible to identify whether a SWEE made any difference to the Distress Score. Conclusion: The SBCN can use the Distress Thermometer tool online to screen for member distress and deal with this distress through information, advice and support or referral to another health professional. A DT scores should be repeated before and after each of the breast cancer treatment stages so that appropriate interventions can be put in place to minimise or prevent the member’s distress. Specialist nurses in other specialised nursing areas can use the distress thermometer to measure and address the problems/issues causing support community members distress. That the content of a SWEE is one way in which members can document and vent about the problems causing their distress and this information can be used by the nurse to put in place appropriate solution or provide advice and support

    Measurements of mixed convective heat transfer to low temperature helium in a horizontal channel

    Get PDF
    A horizontal 2.85 m long, 19 mm i.d. stainless steel heated circular channel was employed to measure coefficients of heat transfer to low temperature helium flow. Experimental parameters range from 6.5 to 15 K, from 0.12 to 0.3 MPa at heat fluxes up to 1000 W/m square and Reynolds numbers from 9,000 to 20,000. A significantly nonuniform distribution of heat transfer coefficients over the tube periphery is observed. Difference between temperatures on the upper and lower surfaces of the stainless steel channel wall was found to reach 9 K. It was noted that the highest temperature on the wall outer surface is displaced from its uppermost point. Measurements of local flow temperatures revealed vortical structure of the flow. The displacement of the point with the highest temperature is attributable to the effect of vortices. The relationships for calculating local and averaged coefficients of heat transfer are proposed

    Some heat transfer and hydrodynamic problems associated with superconducting cables (SPTL)

    Get PDF
    To study some effects of thermogravitation on (CIIK-SPTL) systems, a heated tube experiment was set up at Krzhizhanovsky Power Engineering Institute Moscow, U.S.S.R. Heat transfer data were taken with fluid helium flowing through a 2.85 m, 19 mm diameter uniformly heated horizontal tube. Temperatures were measured on the top and bottom of the tube at six axial locations with three other circumferential measurements made at (X/L) =57. Typical temperature profiles show significant variations both axially and circumferentially. The data are grouped using reduced Nusselt number (NuR) and the bulk expansion parameter for each axial location. The average data for 0.26 less than or equal to X/L less than or equal to 0.76 follow a power law relation with the average expansion parameter. System instabilities are noted and discussed. Future work including heat transfer in coaxial cylinders is discussed

    Test Population Selection from Weibull-Based, Monte Carlo Simulations of Fatigue Life

    Get PDF
    Fatigue life is probabilistic and not deterministic. Experimentally establishing the fatigue life of materials, components, and systems is both time consuming and costly. As a result, conclusions regarding fatigue life are often inferred from a statistically insufficient number of physical tests. A proposed methodology for comparing life results as a function of variability due to Weibull parameters, variability between successive trials, and variability due to size of the experimental population is presented. Using Monte Carlo simulation of randomly selected lives from a large Weibull distribution, the variation in the L10 fatigue life of aluminum alloy AL6061 rotating rod fatigue tests was determined as a function of population size. These results were compared to the L10 fatigue lives of small (10 each) populations from AL2024, AL7075 and AL6061. For aluminum alloy AL6061, a simple algebraic relationship was established for the upper and lower L10 fatigue life limits as a function of the number of specimens failed. For most engineering applications where less than 30 percent variability can be tolerated in the maximum and minimum values, at least 30 to 35 test samples are necessary. The variability of test results based on small sample sizes can be greater than actual differences, if any, that exists between materials and can result in erroneous conclusions. The fatigue life of AL2024 is statistically longer than AL6061 and AL7075. However, there is no statistical difference between the fatigue lives of AL6061 and AL7075 even though AL7075 had a fatigue life 30 percent greater than AL6061

    Probabilistic Analysis for Comparing Fatigue Data Based on Johnson-Weibull Parameters

    Get PDF
    Leonard Johnson published a methodology for establishing the confidence that two populations of data are different. Johnson's methodology is dependent on limited combinations of test parameters (Weibull slope, mean life ratio, and degrees of freedom) and a set of complex mathematical equations. In this report, a simplified algebraic equation for confidence numbers is derived based on the original work of Johnson. The confidence numbers calculated with this equation are compared to those obtained graphically by Johnson. Using the ratios of mean life, the resultant values of confidence numbers at the 99 percent level deviate less than 1 percent from those of Johnson. At a 90 percent confidence level, the calculated values differ between +2 and 4 percent. The simplified equation is used to rank the experimental lives of three aluminum alloys (AL 2024, AL 6061, and AL 7075), each tested at three stress levels in rotating beam fatigue, analyzed using the Johnson- Weibull method, and compared to the ASTM Standard (E739 91) method of comparison. The ASTM Standard did not statistically distinguish between AL 6061 and AL 7075. However, it is possible to rank the fatigue lives of different materials with a reasonable degree of statistical certainty based on combined confidence numbers using the Johnson- Weibull analysis. AL 2024 was found to have the longest fatigue life, followed by AL 7075, and then AL 6061. The ASTM Standard and the Johnson-Weibull analysis result in the same stress-life exponent p for each of the three aluminum alloys at the median, or L(sub 50), live

    Simulation of brush insert for leading-edge-passage convective heat transfer

    Get PDF
    Current and proposed high speed aircraft have high leading edge heat transfer (to 160 MW/sq m, 100 Btu/sq in/sec) and surface temperatures to 1370 K (2000 F). Without cooling, these surfaces could not survive. In one proposal the coolant hydrogen is circulated to the leading edge through a passage and returned to be consumed by the propulsion system. Simulated flow studies and visualizations have shown flow separation within the passage with a stagnation locus that isolates a zone of recirculation at the most critical portion of the passage, namely the leading edge itself. A novel method is described for mitigating the flow separation and the isolated recirculation zones by using a brush insert in the flow passage near the leading edge zone, thus providing a significant increase in heat transfer

    Quantification of Gear Tooth Damage by Optimal Tracking of Vibration Signatures

    Get PDF
    This paper presents a technique for quantifying the wear or damage of gear teeth in a transmission system. The procedure developed in this study can be applied as a part of either an onboard machine health-monitoring system or a health diagnostic system used during regular maintenance. As the developed methodology is based on analysis of gearbox vibration under normal operating conditions, no shutdown or special modification of operating parameters is required during the diagnostic process. The process of quantifying the wear or damage of gear teeth requires a set of measured vibration data and a model of the gear mesh dynamics. An optimization problem is formulated to determine the profile of a time-varying mesh stiffness parameter for which the model output approximates the measured data. The resulting stiffness profile is then related to the level of gear tooth wear or damage. The procedure was applied to a data set generated artificially and to another obtained experimentally from a spiral bevel gear test rig. The results demonstrate the utility of the procedure as part of an overall health-monitoring system
    • …
    corecore