40 research outputs found

    Mucositis en pacientes portadores de cáncer de cabeza y cuello sometidos a radioquimioterapia

    Get PDF
    The objective of present study was to classify oral mucositis according to the Common Toxicity Criterion (CTC) international parameters in head and neck tumor patients simultaneously treated with radio and chemotherapy, and characterize a patient profile in our area, observing the individuals' habits, tumor characteristics, treatment protocol and acute reaction intensity. Fifty patients undergoing simultaneous 66 to 70 Gy megavoltage radiotherapy and cisplatin/carboplatin chemotherapy were evaluated in this study. Weekly evaluations of the degree of mucositis were perfoemed according to CTC, a four-degree ordinal scale; 36% of all patients and 100% of those with diabetes discontinued treatment due to mucositis, showing that this pathology contributes to the severity of mucositis.El trabajo objetivó clasificar el grado de Mucositis oral de acuerdo a parámetros internacionales del CTC en pacientes portadores de tumores de cabeza y cuello sometidos a radioterapia y quimioterapia concomitantes, y caracterizar un perfil de pacientes en nuestro medio, verificando hábitos de los individuos, características del tumor, protocolo de tratamiento e intensidad de esta reacción aguda. Fueron evaluados 50 pacientes sometidos a radioterapia en megavoltaje con dosis entre 66 y 70 G y quimioterapia con cisplatino o carboplatino concomitante. Se evaluó semanalmente el grado de Mucositis según el Common Toxicity Criterio - CTC, una escala ordinal que presenta cuatro grados. Se observó interrupción del tratamiento por Mucositis en 36% del total de pacientes y en 100% de los pacientes diabéticos, lo que nos permite verificar que dicha patología potencia la gravedad de la mucositis.O objetivo do presente trabalho é classificar o grau de mucosite oral de acordo com os parâmetros internacionais do Common Toxicity Criterion (CTC) em pacientes portadores de tumor de cabeça e pescoço submetidos à radioterapia e quimioterapia concomitantes, e caracterizar um perfil dos pacientes em nosso meio, verificando os hábitos dos indivíduos, as características do tumor, o protocolo de tratamento e a intensidade desta reação aguda. Neste estudo foram avaliados 50 pacientes, submetidos à radioterapia em megavoltagem com doses entre 66 a 70 Gy e quimioterapia com cisplatina ou carboplatina concomitante. Semanalmente foi avaliado o grau de mucosite de acordo com o CTC, uma escala ordinal que apresenta 4 graus. Observou-se interrupção do tratamento por mucosite em 36% do total de pacientes e em 100% dos pacientes diabéticos, o que nos permitiu verificar que esta patologia contribui para a gravidade da mucosite.Universidade Federal de São Paulo (UNIFESP)Universidade Federal de São Paulo (UNIFESP) Departamento de Oncologia Programa de Pós-Graduação em RadioterapiaUniversidade Federal de São Paulo (UNIFESP) Departamento de Oncologia Setor de RadioterapiaUniversidade Federal de São Paulo (UNIFESP) Departamento de Oncologia Laboratório de Radioterapia ExperimentalUNIFESP, Depto. de Oncologia Programa de Pós-Graduação em RadioterapiaUNIFESP, Depto. de Oncologia Setor de RadioterapiaUNIFESP, Depto. de Oncologia Laboratório de Radioterapia ExperimentalSciEL

    Mucositis in head and neck cancer patients undergoing radiochemotherapy

    Get PDF
    The objective of present study was to classify oral mucositis according to the Common Toxicity Criterion (CTC) international parameters in head and neck tumor patients simultaneously treated with radio and chemotherapy, and characterize a patient profile in our area, observing the individuals' habits, tumor characteristics, treatment protocol and acute reaction intensity. Fifty patients undergoing simultaneous 66 to 70 Gy megavoltage radiotherapy and cisplatin/carboplatin chemotherapy were evaluated in this study. Weekly evaluations of the degree of mucositis were perfoemed according to CTC, a four-degree ordinal scale; 36% of all patients and 100% of those with diabetes discontinued treatment due to mucositis, showing that this pathology contributes to the severity of mucositis.O objetivo do presente trabalho é classificar o grau de mucosite oral de acordo com os parâmetros internacionais do Common Toxicity Criterion (CTC) em pacientes portadores de tumor de cabeça e pescoço submetidos à radioterapia e quimioterapia concomitantes, e caracterizar um perfil dos pacientes em nosso meio, verificando os hábitos dos indivíduos, as características do tumor, o protocolo de tratamento e a intensidade desta reação aguda. Neste estudo foram avaliados 50 pacientes, submetidos à radioterapia em megavoltagem com doses entre 66 a 70 Gy e quimioterapia com cisplatina ou carboplatina concomitante. Semanalmente foi avaliado o grau de mucosite de acordo com o CTC, uma escala ordinal que apresenta 4 graus. Observou-se interrupção do tratamento por mucosite em 36% do total de pacientes e em 100% dos pacientes diabéticos, o que nos permitiu verificar que esta patologia contribui para a gravidade da mucosite.El trabajo objetivó clasificar el grado de Mucositis oral de acuerdo a parámetros internacionales del CTC en pacientes portadores de tumores de cabeza y cuello sometidos a radioterapia y quimioterapia concomitantes, y caracterizar un perfil de pacientes en nuestro medio, verificando hábitos de los individuos, características del tumor, protocolo de tratamiento e intensidad de esta reacción aguda. Fueron evaluados 50 pacientes sometidos a radioterapia en megavoltaje con dosis entre 66 y 70 G y quimioterapia con cisplatino o carboplatino concomitante. Se evaluó semanalmente el grado de Mucositis según el Common Toxicity Criterio - CTC, una escala ordinal que presenta cuatro grados. Se observó interrupción del tratamiento por Mucositis en 36% del total de pacientes y en 100% de los pacientes diabéticos, lo que nos permite verificar que dicha patología potencia la gravedad de la mucositis

    Efeitos da radiação ionizante na neoformação óssea: estudo histométrico em tíbias de ratos

    Get PDF
    PURPOSE: Comparing the ionizing radiation effects on bone neoformation of rats tibiae previously submitted to radiotherapy with a single dosage of 30Gy with the contralateral tibiae that have received secondary radiation. METHODS: In thirty male Wistar rats, 30 days before surgical procedure when round defects would be created on the bone, the right tibia was irradiated with 30Gy and the left tibia received a calculated secondary radiation dose of 7Gy. Sacrifices were performed after 4, 7, 14, 21, 56 and 84 postoperative days and both tibiae were removed for histological processing. RESULTS: The left tibiae that received the dose of 7Gy has shown more bone neoformation from 14th postoperative days, giving evidences of less damage to cellular population responsible by bone neoformation. On the other hand, the dose of 30Gyon right tibiae did not exhibit significant differences among the periods, suggesting damage of long-lasting or even permanent duration. CONCLUSION: Tibiae submitted to radiation dose of 30Gy have shown more damage to bone cells than tibiae that received secondary radiation dose of 7Gy, especially observed on 14th, 56th and 84th postoperative days.OBJETIVO: Comparar os efeitos da radiação ionizante na reparação óssea em tíbias de ratos, submetidas à radioterapia prévia com doses 30Gy, com as tíbias contralaterais que receberam radiação secundária. MÉTODOS: No total, 30 ratos Wistar machos foram submetidos à cirurgia para realização de defeitos circulares em ambas as tíbias de cada rato, com radioterapia prévia de 30 dias, sendo que a tíbia direita recebeu a dose de 30Gy e tíbia esquerda a dose de radiação secundária calculada em 7Gy. Os sacrifícios ocorreram em 4, 7, 14, 21, 56 e 84 dias da realização do defeito ósseo e as tíbias foram removidas para processamento histológico. RESULTADOS: O grupo de 7Gy apresentou maior neoformação a partir do período de 14 dias, indicando pouco dano aos elementos celulares responsáveis pela reparação óssea, enquanto que o grupo de 30Gy não apresentou diferenças significantes entre os períodos, sugerindo um dano de efeito prolongado ou até mesmo permanente. CONCLUSÃO: As tíbias irradiadas com 30Gy apresentaram maior dano às células ósseas do que as tíbias que receberam radiação secundária de 7Gy, principalmente observadas nos períodos de 14, 56 e 84 dias.Universidade Federal de São Paulo (UNIFESP) Department of Otorhinolaringology and Head and Neck SurgeryPaulista University Faculty of Dentistry Department of StomatologyUniversidade Federal de São Paulo (UNIFESP) Department of OncologyUniversidade Federal de São Paulo (UNIFESP) Department of PathologyUNIFESP, Department of Otorhinolaringology and Head and Neck SurgeryUNIFESP, Department of OncologyUNIFESP, Department of PathologySciEL

    Measurement of absorbed radiation doses during whole body irradiation for bone marrow transplants using thermoluminescent dosimeters

    No full text
    OBJECTIVE: To evaluate the precision of the absorbed radiation doses in bone marrow transplant therapy during whole body irradiation. MATERIALS AND METHODS: Two-hundred CaSO4:Dy + teflon tablets were calibrated in air and in phantom. These tablets were randomly selected and divided in groups of five in the patients' body. The dosimetric readings were obtained using a Harshaw 4000A reader. Nine patients had their entire bodies irradiated in parallel and opposite laterals in a cobalt-60 Alcion II model, with a dose rate of 0.80 Gy/min at 80.5 cm, {(10 × 10) cm² field}. The dosimetry of this unit was performed using a Victoreen 500 dosimeter. For the determination of the mean dose at each point evaluated, the individual values of the tablets calibrated in air or phantom were used, resulting in a build up of 2 mm to superficialize the dose at a distance of 300 cm. RESULTS: In 70% of the patients a variation of less than 5% in the dose was obtained. In 30% of the patients this variation was less than 10%, when values obtained were compared to the values calculated at each point. A mean absorption of 14% was seen in the head, and an increase of 2% of the administered dose was seen in the lungs. In patients with latero-lateral distance greater than 35 cm the variation between the calculated doses and the measured doses reached 30% of the desired dose, without the use of compensation filters. CONCLUSION: The measured values of the absorbed doses at the various anatomic points compared to the desired doses (theoretic) presented a tolerance of ± 10%, considering the existent anatomical differences and when using the individual calibration factors of the tablets.OBJETIVO: Avaliar a precisão das doses de radiação absorvidas na terapia de transplantes de medula óssea durante a técnica de irradiação de corpo inteiro. MATERIAIS E MÉTODOS: Utilizaram-se 200 pastilhas de sulfato de cálcio com disprósio compactado com teflon (CaSO4 + teflon), calibradas no ar e no phantom, selecionadas aleatoriamente e dispostas em grupos de cinco no corpo dos pacientes. As leituras dosimétricas foram efetuadas pela leitora Harshaw 4000A. Nove pacientes foram irradiados no corpo inteiro em paralelos e em opostos laterais, utilizando-se unidade de cobalto-60, modelo Alcion II, com taxa de dose de 0,80 Gy/min a 80,5 cm, {campo (10 × 10) cm²}. A dosimetria dessa unidade foi realizada com dosímetro Victoreen 500. Para a determinação da dose média em cada ponto avaliado usaram-se os fatores individuais de calibração das pastilhas no ar e no phantom, colocando-se um build up de 2 mm para superficializar a dose à distância de 300 cm. RESULTADOS: Em 70% dos pacientes obteve-se variação de dose menor que 5% e em 30% dos pacientes essa variação foi inferior a 10%, quando comparados os valores medidos com aqueles calculados em cada ponto. Na cabeça ocorre absorção, em média, de 14% da dose administrada, e nos pulmões, acréscimo de 2% na dose administrada. Nos pacientes com distância látero-lateral maior que 35 cm as variações entre as doses calculadas e medidas podem chegar a 30% da dose desejada, sem o uso de filtros compensadores. CONCLUSÃO: Os valores medidos das doses absorvidas nos diversos pontos anatômicos, comparados aos valores desejados (teóricos), apresentam tolerância de ±10%, considerando-se as diferenças anatômicas existentes, quando utilizados os fatores de calibração individuais das pastilhas.UNIFESP-EPMUNIFESP-EPM Departamento de MedicinaUNIFESP-EPM Departamento de Diagnóstico por ImagemUNIFESP, EPM, Depto. de MedicinaUNIFESP, EPM Depto. de Diagnóstico por ImagemSciEL
    corecore