14 research outputs found

    Approaches for the optimization of MR protocols in clinical hybrid PET/MRI studies

    Get PDF
    Magnetic resonance imaging (MRI) is the examination method of choice for the diagnosis of a variety of diseases. MRI allows us to obtain not only anatomical information but also identification of physiological and functional parameters such as networks in the brain and tumor cellularity, which plays an increasing role in oncologic imaging, as well as blood flow and tissue perfusion. However, in many cases such as in epilepsy, degenerative neurological diseases and oncological processes, additional metabolic and molecular information obtained by PET can provide essential complementary information for better diagnosis. The combined information obtained from MRI and PET acquired in a single imaging session allows a more accurate localization of pathological findings and better assessment of the underlying physiopathology, thus providing a more powerful diagnostic tool. Two hundred and twenty-one patients were scanned from April 2011 to January 2012 on a Philips Ingenuity TF PET/MRI system. The purpose of this review article is to provide an overview of the techniques used for the optimization of different protocols performed in our hospital by specialists in the following fields: neuroradiology, head and neck, breast, and prostate imaging. This paper also discusses the different problems encountered, such as the length of studies, motion artifacts, and accuracy of image fusion including physical and technical aspects, and the proposed solution

    Accurate determination of brain metabolite concentrations using ERETIC as external reference

    Full text link
    Magnetic Resonance Spectroscopy (MRS) can provide in vivo metabolite concentrations in standard concentration units if a reliable reference signal is available. For 1H MRS in the human brain, typically the signal from the tissue water is used as the (internal) reference signal. However, a concentration determination based on the tissue water signal most often requires a reliable estimate of the water concentration present in the investigated tissue. Especially in clinically interesting cases, this estimation might be difficult. To avoid assumptions about the water in the investigated tissue, the Electric REference To access In vivo Concentrations (ERETIC) method has been proposed. In this approach, the metabolite signal is compared with a reference signal acquired in a phantom and potential coil-loading differences are corrected using a synthetic reference signal. The aim of this study, conducted with a transceiver quadrature head coil, was to increase the accuracy of the ERETIC method by correcting the influence of spatial B1 inhomogeneities and to simplify the quantification with ERETIC by incorporating an automatic phase correction for the ERETIC signal. Transmit field (B1 +) differences are minimized with a volume-selective power optimization, whereas reception sensitivity changes are corrected using contrast-minimized images of the brain and by adapting the voxel location in the phantom measurement closely to the position measured in vivo. By applying the proposed B1 correction scheme, the mean metabolite concentrations determined with ERETIC in 21 healthy subjects at three different positions agree with concentrations derived with the tissue water signal as reference. In addition, brain water concentrations determined with ERETIC were in agreement with estimations derived using tissue segmentation and literature values for relative water densities. Based on the results, the ERETIC method presented here is a valid tool to derive in vivo metabolite concentration, with potential advantages compared with internal water referencing in diseased tissue

    Fat-constrained 18F-FDG PET reconstruction in hybrid PET/MR imaging

    No full text
    Fusion of information from PET and MR imaging can increase the diagnostic value of both modalities. This work sought to improve (18)F FDG PET image quality by using MR Dixon fat-constrained images to constrain PET image reconstruction to low-fat regions, with the working hypothesis that fatty tissue metabolism is low in glucose consumption

    Approaches for the optimization of MR protocols in clinical hybrid PET/MRI studies

    No full text
    Magnetic resonance imaging (MRI) is the examination method of choice for the diagnosis of a variety of diseases. MRI allows us to obtain not only anatomical information but also identification of physiological and functional parameters such as networks in the brain and tumor cellularity, which plays an increasing role in oncologic imaging, as well as blood flow and tissue perfusion. However, in many cases such as in epilepsy, degenerative neurological diseases and oncological processes, additional metabolic and molecular information obtained by PET can provide essential complementary information for better diagnosis. The combined information obtained from MRI and PET acquired in a single imaging session allows a more accurate localization of pathological findings and better assessment of the underlying physiopathology, thus providing a more powerful diagnostic tool. Two hundred and twenty-one patients were scanned from April 2011 to January 2012 on a Philips Ingenuity TF PET/MRI system. The purpose of this review article is to provide an overview of the techniques used for the optimization of different protocols performed in our hospital by specialists in the following fields: neuroradiology, head and neck, breast, and prostate imaging. This paper also discusses the different problems encountered, such as the length of studies, motion artifacts, and accuracy of image fusion including physical and technical aspects, and the proposed solutions

    Clinical applications of hybrid PET/MRI in neuroimaging

    No full text
    We tested the performance and clinical applicability of combined protocols for brain imaging studies acquired on a new whole-body hybrid PET/MR scanner

    All-in-one interictal presurgical imaging in patients with epilepsy: single-session EEG/PET/(f)MRI

    No full text
    Purpose: In patients with pharmacoresistant focal epilepsy, resection of the epileptic focus can lead to freedom from seizures or significant improvement in well-selected candidates. Localization of the epileptic focus with multimodal concordance is crucial for a good postoperative outcome. Beyond the detection of epileptogenic lesions on structural MRI and focal hypometabolism on FDG PET, EEG-based Electric Source Imaging (ESI) and simultaneous EEG and functional MRI (EEG-fMRI) are increasingly applied for mapping epileptic activity. We here report presurgical multimodal interictal imaging using a hybrid PET/MR scanner for single-session FDG PET, MRI, EEG-fMRI and ESI. Methods: This quadrimodal imaging procedure was performed in a single session in 12 patients using a high-density (256 electrodes) MR-compatible EEG system and a hybrid PET/MR scanner. EEG was used to exclude subclinical seizures during uptake of the PET tracer, to compute ESI on interictal epileptiform discharges and to guide fMRI analysis for mapping haemodynamic changes correlated with interictal epileptiform activity. Results: The whole multimodal recording was performed in less than 2hours with good patient comfort and data quality. Clinically contributory examinations with at least two modalities were obtained in nine patients and with all modalities in five patients. Conclusion: This single-session quadrimodal imaging procedure provided reliable and contributory interictal clinical data. This procedure avoids multiple scanning sessions and is associated with less radiation exposure than PET-CT. Moreover, it guarantees the same medication level and medical condition for all modalities. The procedure improves workflow and could reduce the duration and cost of presurgical epilepsy evaluations

    Mitochondrial capacity is affected by glycemic status in young untrained women with type 1 diabetes but is not impaired relative to healthy untrained women

    Full text link
    In this study, we examined whether glycemic status influences aerobic function in women with type 1 diabetes and whether aerobic function is reduced relative to healthy women. To this end, we compared several factors determining aerobic function of 29 young sedentary asymptomatic women (CON) with 9 women of similar age and activity level with type 1 diabetes [DIA, HbA1c range = 6.9-8.2%]. Calf muscle mitochondrial capacity was estimated by (31)P-Magnetic Resonance Spectroscopy. Capillarization and muscle fiber oxidative enzyme activity were assessed from vastus lateralis and soleus muscle biopsies. Oxygen uptake and cardiac output were evaluated by ergospirometry and N(2)O/SF(6) rebreathing. Calf muscle mitochondrial capacity was not different between CON and DIA, as indicated by the identical calculated maximal rates of oxidative ATP synthesis [0.0307 (0.0070) vs. 0.0309 (0.0058) s(-1), P = 0.930]. Notably, HbA1c was negatively correlated with mitochondrial capacity in DIA (R(2) = 0.475, P = 0.040). Although HbA1c was negatively correlated with cardiac output (R(2) = 0.742, P = 0.013) in DIA, there was no difference between CON and DIA in maximal oxygen consumption [2.17 (0.34) vs. 2.21 (0.32) lâ‹…min(-1), P = 0.764], cardiac output [12.1 (1.9) vs. 12.3 (1.8) lâ‹…min(-1), P = 0.783], and endurance capacity [532 (212) vs. 471 (119) s, P = 0.475]. There was also no difference between the two groups either in the oxidative enzyme activity or capillary-to-fiber ratio. We conclude that mitochondrial capacity depends on HbA1c in untrained women with type 1 diabetes but is not reduced relative to untrained healthy women

    All-in-one interictal presurgical imaging in patients with epilepsy: single-session EEG/PET/(f)MRI.

    No full text
    In patients with pharmacoresistant focal epilepsy, resection of the epileptic focus can lead to freedom from seizures or significant improvement in well-selected candidates. Localization of the epileptic focus with multimodal concordance is crucial for a good postoperative outcome. Beyond the detection of epileptogenic lesions on structural MRI and focal hypometabolism on FDG PET, EEG-based Electric Source Imaging (ESI) and simultaneous EEG and functional MRI (EEG-fMRI) are increasingly applied for mapping epileptic activity. We here report presurgical multimodal interictal imaging using a hybrid PET/MR scanner for single-session FDG PET, MRI, EEG-fMRI and ESI
    corecore