83 research outputs found
Mechanical losses in low loss materials studied by Cryogenic Resonant Acoustic spectroscopy of bulk materials (CRA spectroscopy)
Mechanical losses of crystalline silicon and calcium fluoride have been
analyzed in the temperature range from 5 to 300 K by our novel mechanical
spectroscopy method, cryogenic resonant acoustic spectroscopy of bulk materials
(CRA spectrocopy). The focus lies on the interpretation of the measured data
according to phonon-phonon interactions and defect induced losses in
consideration of the excited mode shape.Comment: 4 pages, 4 figures, proceedings of the PHONONS 2007, submitted to
Journal of Physics: Conference Serie
Thermal noise of folding mirrors
Current gravitational wave detectors rely on the use of Michelson interferometers. One crucial limitation of their sensitivity is the thermal noise of their optical components. Thus, for example fluctuational deformations of the mirror surface are probed by a laser beam being reflected from the mirrors at normal incidence. Thermal noise models are well evolved for that case but mainly restricted to single reflections. In this work we present the effect of two consecutive reflections under a non-normal incidence onto mirror thermal noise. This situation is inherent to detectors using a geometrical folding scheme such as GEO\,600. We revise in detail the conventional direct noise analysis scheme to the situation of non-normal incidence allowing for a modified weighting funtion of mirror fluctuations. An application of these results to the GEO\,600 folding mirror for Brownian, thermoelastic and thermorefractive noise yields an increase of displacement noise amplitude by 20\% for most noise processes. The amplitude of thermoelastic substrate noise is increased by a factor 4 due to the modified weighting function. Thus the consideration of the correct weighting scheme can drastically alter the noise predictions and demands special care in any thermal noise design process
Potential mechanical loss mechanisms in bulk materials for future gravitational wave detectors
Low mechanical loss materials are needed to further decrease thermal noise in
upcoming gravitational wave detectors. We present an analysis of the
contribution of Akhieser and thermoelastic damping on the experimental results
of resonant mechanical loss measurements. The combination of both processes
allows the fit of the experimental data of quartz in the low temperature region
(10 K to 25 K). A fully anisotropic numerical calculation over a wide
temperature range (10 K to 300 K) reveals, that thermoelastic damping is not a
dominant noise source in bulk silicon samples. The anisotropic numerical
calculation is sucessfully applied to the estimate of thermoelastic noise of an
advanced LIGO sized silicon test mass.Comment: 7 pages, 3 figures, submitted to Journal of Physics: Conference
Series (AMALDI8
Thermorefractive noise of finite-sized cylindrical test masses
We present an analytical solution for the effect of thermorefractive noise considering finite-sized cylindrical test masses. For crystalline materials at low temperatures, the effect of finite dimensions becomes important. The calculations are independently performed using the Fluctuation-Dissipation-Theorem and Langevin's approach. Our results are applied to the input test mass of the current and future cryogenic gravitational wave detectors CLIO, LCGT, and ET and are compared to the respective standard quantum limit. For a substrate temperature of 10 K, we find that the thermorefractive noise amplitude of the silicon input test mass in ET is only a factor of 2 below the standard quantum limit for frequencies above 500 Hz. Thus, thermorefractive noise of the input test mass could become a severe limitation if one uses techniques to beat the standard quantum limit like, e.g., squeezing. In contrast, the effect of thermorefractive noise of the input test mass is negligible for CLIO and LCGT
A New Bound on Excess Frequency Noise in Second Harmonic Generation in PPKTP at the 10^-19 Level
We report a bound on the relative frequency fluctuations in nonlinear second
harmonic generation. A 1064nm Nd:YAG laser is used to read out the phase of a
Mach-Zehnder interferometer while PPKTP, a nonlinear crystal, is placed in each
arm to generate second harmonic light. By comparing the arm length difference
of the Mach Zehnder as read out by the fundamental 1064 nm light, and its
second harmonic at 532 nm, we can bound the excess frequency noise introduced
in the harmonic generation process. We report an amplitude spectral density of
frequency noise with total RMS frequency deviation of 3mHz and a minimum value
of 20 {\mu}Hz/rtHz over 250 seconds with a measurement bandwidth of 128 Hz,
corresponding to an Allan deviation of 10^-19 at 20 seconds.Comment: Submitted to Optics Express June 201
High-sensitivity tool for studying phonon related mechanical losses in low loss materials
Fundamental mechanical loss mechanisms exist even in very pure materials, for
instance, due to the interactions of excited acoustic waves with thermal
phonons. A reduction of these losses in a certain frequency range is desired in
high precision instruments like gravitational wave detectors. Systematic
analyses of the mechanical losses in those low loss materials are essential for
this aim, performed in a highly sensitive experimental set-up. Our novel method
of mechanical spectroscopy, cryogenic resonant acoustic spectroscopy of bulk
materials (CRA spectroscopy), is well suited to systematically determine losses
at the resonant frequencies of the samples of less than 10^(-9) in the wide
temperature range from 5 to 300 K. A high precision set-up in a specially built
cryostat allows contactless excitation and readout of the oscillations of the
sample. The experimental set-up and measuring procedure are described.
Limitations to our experiment due to external loss mechanisms are analysed. The
influence of the suspension system as well as the sample preparation is
explained.Comment: 4 pages, 3 figures, proceedings of PHONONS07, submitted to Journal of
Physics: Conference Serie
Indium joints for cryogenic gravitational wave detectors
A viable technique for the preparation of highly thermal conductive joints between sapphire components in gravitational wave detectors is presented. The mechanical loss of such a joint was determined to be as low as 2 × 10−3 at 20 K and 2 × 10−2 at 300 K. The thermal noise performance of a typical joint is compared to the requirements of the Japanese gravitational wave detector, KAGRA. It is shown that using such an indium joint in the suspension system allows it to operate with low thermal noise. Additionally, results on the maximum amount of heat which can be extracted via indium joints are presented. It is found that sapphire parts, joined by means of indium, are able to remove the residual heat load in the mirrors of KAGRA
Measurement of the optical absorption of bulk silicon at cryogenic temperature and the implication for the Einstein Telescope
International audienceWe report in this article on the measurement of the optical absorption of moderately doped crystalline silicon samples at 1550 nm, which is a candidate material for the main optics of the low temperature interferometer of the Einstein Telescope (ET). We observe a nearly constant absorption from room temperature down to cryogenic temperatures for two silicon samples presenting an optical absorption of 0.029 cm −1 and 780 ppm cm −1 , both crystals doped with boron. This is in contradiction to what was assumed previously—a negligible optical absorption at low temperature due to the carrier freezeout. As the main consequence, if the silicon intrinsic absorption can not be lowered , the cross section of the mirror suspension of the ET must be increased to be able to carry away the excess heat generated by the partially absorbed laser beam during the operation of the interferometer
- …