121 research outputs found

    The Matter in Extreme Conditions instrument at the Linac Coherent Light Source

    Get PDF
    The LCLS beam provides revolutionary capabilities for studying the transient behavior of matter in extreme conditions. The particular strength of the Matter in Extreme Conditions instrument is that it combines the unique LCLS beam with high-power optical laser beams, and a suite of dedicated diagnostics tailored for this field of science. In this paper an overview of the beamline, the capabilities of the instrumentation, and selected highlights of experiments and commissioning results are presented

    Measurement of the cosmic ray spectrum above 4×10184{\times}10^{18} eV using inclined events detected with the Pierre Auger Observatory

    Full text link
    A measurement of the cosmic-ray spectrum for energies exceeding 4×10184{\times}10^{18} eV is presented, which is based on the analysis of showers with zenith angles greater than 60∘60^{\circ} detected with the Pierre Auger Observatory between 1 January 2004 and 31 December 2013. The measured spectrum confirms a flux suppression at the highest energies. Above 5.3×10185.3{\times}10^{18} eV, the "ankle", the flux can be described by a power law E−γE^{-\gamma} with index Îł=2.70±0.02 (stat)±0.1 (sys)\gamma=2.70 \pm 0.02 \,\text{(stat)} \pm 0.1\,\text{(sys)} followed by a smooth suppression region. For the energy (EsE_\text{s}) at which the spectral flux has fallen to one-half of its extrapolated value in the absence of suppression, we find Es=(5.12±0.25 (stat)−1.2+1.0 (sys))×1019E_\text{s}=(5.12\pm0.25\,\text{(stat)}^{+1.0}_{-1.2}\,\text{(sys)}){\times}10^{19} eV.Comment: Replaced with published version. Added journal reference and DO

    Energy Estimation of Cosmic Rays with the Engineering Radio Array of the Pierre Auger Observatory

    Full text link
    The Auger Engineering Radio Array (AERA) is part of the Pierre Auger Observatory and is used to detect the radio emission of cosmic-ray air showers. These observations are compared to the data of the surface detector stations of the Observatory, which provide well-calibrated information on the cosmic-ray energies and arrival directions. The response of the radio stations in the 30 to 80 MHz regime has been thoroughly calibrated to enable the reconstruction of the incoming electric field. For the latter, the energy deposit per area is determined from the radio pulses at each observer position and is interpolated using a two-dimensional function that takes into account signal asymmetries due to interference between the geomagnetic and charge-excess emission components. The spatial integral over the signal distribution gives a direct measurement of the energy transferred from the primary cosmic ray into radio emission in the AERA frequency range. We measure 15.8 MeV of radiation energy for a 1 EeV air shower arriving perpendicularly to the geomagnetic field. This radiation energy -- corrected for geometrical effects -- is used as a cosmic-ray energy estimator. Performing an absolute energy calibration against the surface-detector information, we observe that this radio-energy estimator scales quadratically with the cosmic-ray energy as expected for coherent emission. We find an energy resolution of the radio reconstruction of 22% for the data set and 17% for a high-quality subset containing only events with at least five radio stations with signal.Comment: Replaced with published version. Added journal reference and DO

    Measurement of the Radiation Energy in the Radio Signal of Extensive Air Showers as a Universal Estimator of Cosmic-Ray Energy

    Full text link
    We measure the energy emitted by extensive air showers in the form of radio emission in the frequency range from 30 to 80 MHz. Exploiting the accurate energy scale of the Pierre Auger Observatory, we obtain a radiation energy of 15.8 \pm 0.7 (stat) \pm 6.7 (sys) MeV for cosmic rays with an energy of 1 EeV arriving perpendicularly to a geomagnetic field of 0.24 G, scaling quadratically with the cosmic-ray energy. A comparison with predictions from state-of-the-art first-principle calculations shows agreement with our measurement. The radiation energy provides direct access to the calorimetric energy in the electromagnetic cascade of extensive air showers. Comparison with our result thus allows the direct calibration of any cosmic-ray radio detector against the well-established energy scale of the Pierre Auger Observatory.Comment: Replaced with published version. Added journal reference and DOI. Supplemental material in the ancillary file

    Impact of the first COVID lockdown on accident- and injury-related pediatric intensive care admissions in Germany - a multicenter study

    Get PDF
    Children’s and adolescents’ lives drastically changed during COVID lockdowns worldwide. To compare accident- and injury-related admissions to pediatric intensive care units (PICU) during the first German COVID lockdown with previous years, we conducted a retrospective multicenter study among 37 PICUs (21.5% of German PICU capacities). A total of 1444 admissions after accidents or injuries during the first lockdown period and matched periods of 2017–2019 were reported and standardized morbidity ratios (SMR) were calculated. Total PICU admissions due to accidents/injuries declined from an average of 366 to 346 (SMR 0.95 (CI 0.85–1.05)). Admissions with trauma increased from 196 to 212 (1.07 (0.93–1.23). Traffic accidents and school/kindergarten accidents decreased (0.77 (0.57–1.02 and 0.26 (0.05–0.75)), whereas household and leisure accidents increased (1.33 (1.06–1.66) and 1.34 (1.06–1.67)). Less neurosurgeries and more visceral surgeries were performed (0.69 (0.38–1.16) and 2.09 (1.19–3.39)). Non-accidental non-suicidal injuries declined (0.73 (0.42–1.17)). Suicide attempts increased in adolescent boys (1.38 (0.51–3.02)), but decreased in adolescent girls (0.56 (0.32–0.79)). In summary, changed trauma mechanisms entailed different surgeries compared to previous years. We found no evidence for an increase in child abuse cases requiring intensive care. The increase in suicide attempts among boys demands investigation

    Postoperative serum proteomic profiles may predict recurrence-free survival in high-risk primary breast cancer

    Get PDF
    Item does not contain fulltextPURPOSE: Better breast cancer prognostication may improve selection of patients for adjuvant therapy. We conducted a retrospective longitudinal study in which we investigated sera of high-risk primary breast cancer patients, to search for proteins predictive of recurrence-free survival. METHODS: Sera of 82 breast cancer patients obtained after surgery, but prior to the administration of adjuvant therapy, were fractionated using anion-exchange chromatography, to facilitate the detection of the low-abundant serum peptides. Selected fractions were subsequently analysed by surface-enhanced laser desorption/ionisation time-of-flight mass spectrometry (SELDI-TOF MS), and the resulting protein profiles were searched for prognostic markers by appropriate bioinformatics tools. RESULTS: Four peak clusters (i.e. m/z 3073, m/z 3274, m/z 4405 and m/z 7973) were found to bear significant prognostic value (P </= 0.01). The m/z 3274 candidate marker was structurally identified as inter-alpha-trypsin inhibitor heavy chain 4 fragment(658-688) in serum. Except for the m/z 7973 peak cluster, these peaks remained independently associated with recurrence-free survival upon multivariate Cox regression analysis, including clinical parameters of known prognostic value in this study population. CONCLUSION: Investigation of the postoperative serum proteome by, e.g., anion-exchange fractionation followed by SELDI-TOF MS analysis is promising for the detection of novel prognostic factors. However, regarding the rather limited study population, validation of these results by analysis of independent study populations is warranted to assess the true clinical applicability of discovered prognostic markers. In addition, structural identification of the other markers will aid in elucidation of their role in breast cancer prognosis, as well as enable development of absolute quantitative assays

    The soft x-ray instrument for materials studies at the linac coherent light source x-ray free-electron laser

    Get PDF
    This content may be downloaded for personal use only. Any other use requires prior permission of the author and AIP Publishing. This material originally appeared in Review of Scientific Instruments 83, 043107 (2012) and may be found at https://doi.org/10.1063/1.3698294.The soft x-ray materials science instrument is the second operational beamline at the linac coherent light source x-ray free electron laser. The instrument operates with a photon energy range of 480–2000 eV and features a grating monochromator as well as bendable refocusing mirrors. A broad range of experimental stations may be installed to study diverse scientific topics such as: ultrafast chemistry, surface science, highly correlated electron systems, matter under extreme conditions, and laboratory astrophysics. Preliminary commissioning results are presented including the first soft x-ray single-shot energy spectrum from a free electron laser
    • 

    corecore