1,117 research outputs found
Recommended from our members
Characteristics and influence of biosmoke on the fine-particle ionic composition measured in Asian outflow during the Transport and Chemical Evolution Over the Pacific (TRACE-P) experiment
Measurement of the Branching Fraction of J/psi --> pi+ pi- pi0
Using 58 million J/psi and 14 million psi' decays obtained by the BESII
experiment, the branching fraction of J/psi --> pi+ pi- pi0 is determined. The
result is (2.10+/-0.12)X10^{-2}, which is significantly higher than previous
measurements.Comment: 9 pages, 8 figures, RevTex
First observation of psi(2S)-->K_S K_L
The decay psi(2S)-->K_S K_L is observed for the first time using psi(2S) data
collected with the Beijing Spectrometer (BESII) at the Beijing Electron
Positron Collider (BEPC); the branching ratio is determined to be
B(psi(2S)-->K_S K_L) = (5.24\pm 0.47 \pm 0.48)\times 10^{-5}. Compared with
J/psi-->K_S K_L, the psi(2S) branching ratio is enhanced relative to the
prediction of the perturbative QCD ``12%'' rule. The result, together with the
branching ratios of psi(2S) decays to other pseudoscalar meson pairs
(\pi^+\pi^- and K^+K^-), is used to investigate the relative phase between the
three-gluon and the one-photon annihilation amplitudes of psi(2S) decays.Comment: 5 pages, 4 figures, 2 tables, submitted to Phys. Rev. Let
Search for K_S K_L in psi'' decays
K_S K_L from psi'' decays is searched for using the psi'' data collected by
BESII at BEPC, the upper limit of the branching fraction is determined to be
B(psi''--> K_S K_L) < 2.1\times 10^{-4} at 90% C. L. The measurement is
compared with the prediction of the S- and D-wave mixing model of the
charmonia, based on the measurements of the branching fractions of J/psi-->K_S
K_L and psi'-->K_S K_L.Comment: 5 pages, 1 figur
First Measurements of eta_c Decaying into K^+K^-2(pi^+pi^-) and 3(pi^+pi^-)
The decays of eta_c to K^+K^-2(pi^+pi^-) and 3(pi^+pi^-) are observed for the
first time using a sample of 5.8X10^7 J/\psi events collected by the BESII
detector. The product branching fractions are determined to be B(J/\psi-->gamma
eta_c)*B(eta_c-->K^+K^-pi^+pi^-pi^+pi^-)=(1.21+-0.32+-
0.23)X10^{-4}, and (J/\psi-->gamma eta_c)*
B(eta_c-->pi^+pi^-pi^+pi^-pi^+pi^-)= (2.59+-0.32+-0.48)X10^{-4}. The upper
limit for eta_c-->phi pi^+pi^-pi^+pi^- is also obtained as B(J/\psi-->gamma
eta_c)*B(eta_c--> phi pi^+pi^-pi^+pi^-)< 6.03 X10^{-5} at the 90% confidence
level.Comment: 11 pages, 4 figure
Study of psi(2S) decays to X J/psi
Using J/psi -> mu^+ mu^- decays from a sample of approximately 4 million
psi(2S) events collected with the BESI detector, the branching fractions of
psi(2S) -> eta J/psi, pi^0 pi^0 J/psi, and anything J/psi normalized to that of
psi(2S) -> pi^+ pi^- J/psi are measured. The results are B(psi(2S) -> eta
J/psi)/B(psi(2S) -> pi^+ pi^- J/psi) = 0.098 \pm 0.005 \pm 0.010, B(psi(2S) ->
pi^0 pi^0 J/psi)/B(psi(2S) -> pi^+ pi^- J/psi) = 0.570 \pm 0.009 \pm 0.026, and
B(psi(2S) -> anything J/psi)/B(psi(2S) -> pi^+ pi^- J/psi) = 1.867 \pm 0.026
\pm 0.055.Comment: 13 pages, 8 figure
Wavelength-scale stationary-wave integrated Fourier-transform spectrometry
Spectrometry is a general physical-analysis approach for investigating
light-matter interactions. However, the complex designs of existing
spectrometers render them resistant to simplification and miniaturization, both
of which are vital for applications in micro- and nanotechnology and which are
now undergoing intensive research. Stationary-wave integrated Fourier-transform
spectrometry (SWIFTS)-an approach based on direct intensity detection of a
standing wave resulting from either reflection (as in the principle of colour
photography by Gabriel Lippmann) or counterpropagative interference
phenomenon-is expected to be able to overcome this drawback. Here, we present a
SWIFTS-based spectrometer relying on an original optical near-field detection
method in which optical nanoprobes are used to sample directly the evanescent
standing wave in the waveguide. Combined with integrated optics, we report a
way of reducing the volume of the spectrometer to a few hundreds of cubic
wavelengths. This is the first attempt, using SWIFTS, to produce a very small
integrated one-dimensional spectrometer suitable for applications where
microspectrometers are essential
- …