126 research outputs found
Mitral Valve Replacement With the 15-mm Mechanical Valve:A 20-Year Multicenter Experience
Background: The aim of this study was to evaluate early and long-term outcomes (mortality and prosthetic valve replacement) after mitral valve replacement with the 15-mm St Jude Medical prosthesis (St Jude Medical, St Paul, MN). Methods: A multicenter, retrospective cohort study was performed among patients who underwent mitral valve replacement with a 15-mm St Jude Medical Masters prosthesis at 4 congenital cardiac centers in The Netherlands. Operative results were evaluated and echocardiographic data studied at 0.5, 1, 2, 3, 5, and 10 years after surgery. Results: Surgery was performed in 17 infants. Ten patients (59%) were treated in the intensive care unit before surgery; 8 (47%) were on ventilator support. Median age at surgery was 3.2 months (interquartile range [IQR], 1.2-5.6), and median weight was 5.2 kg (IQR 3.9-5.7). There was 1 early cardiac death and 1 late noncardiac death. Median follow-up time was 9.6 years (IQR, 2.4-13.2), including 8 patients with a follow-up more than 10 years. The first prosthetic valve explantation (n = 11) occurred at a median of 2.9 years (IQR, 2.0-5.4). Other reinterventions were permanent pacemaker implantation (n = 3), subaortic stenosis resection (n = 2), and paravalvular leak repair (n = 1). Prosthetic valve gradients increased from a mean of 5.0 mm Hg (at discharge) to a mean of 14.3 mm Hg (at 5-year follow-up). Conclusions: Mitral valve replacement with the 15-mm prosthesis can safely be performed in infants and even in neonates. Median freedom from prosthesis replacement for outgrowth is 3.5 years. Thromboembolic complications were rare.</p
Time Course of Diastolic and Systolic Function Improvement After Pulmonary Valve Replacement in Adult Patients With Tetralogy of Fallot
ObjectivesThe aim of this research was to assess right ventricular diastolic and systolic function before and after pulmonary valve replacement (PVR) in adult patients after repair of tetralogy of Fallot.BackgroundPulmonary valve replacement (PVR) in adult patients late after repair of tetralogy of Fallot leads to rapid improvement of right ventricular (RV) systolic function.MethodsA total of 16 patients and 8 healthy subjects were included. Median age at initial repair was 4.9 (0.9 to 13.1) years, and mean age at PVR was 28.7 (19.5 to 45.6) years. Cardiac magnetic resonance imaging was performed before and 8 and 22 months after PVR. Right ventricular volumes and function as well as RV in- and outflow patterns were assessed.ResultsThe volume of the early filling of the RV (Evol) increased from 49.8 ± 14.7 ml to 53.8 ± 19.3 ml (not significant) and 62.0 ± 18.9 ml, respectively (p < 0.05), whereas the volume of the atrial contraction (Avol) remained unchanged. Consequently, the Evol/Avol ratio increased from 1.4 ± 0.7 before PVR to 1.6 ± 0.7 at 8 months (not significant) and 2.3 ± 1.2 at 22 months (p < 0.01). The Evol/Avol ratio was not significantly different from the healthy subjects at 22 months, indicating late recovery of diastolic function. Systolic function improved rapidly after PVR; the indexed RV end-systolic volume decreased from 93.7 ± 33.0 ml/m2to 60.9 ± 18.4 ml/m2(p < 0.01) and 54.8 ± 21.0 ml/m2(p < 0.01).ConclusionsIn adult patients late after total repair of Fallot, PVR leads to late improvement of diastolic function. We speculate that the rapid volume unloading after PVR increases systolic performance, whereas improvement in diastolic function requires long-term remodeling
Long-Term Follow-Up of Pericardium for the Ventricular Component in Atrioventricular Septal Defect Repair
Background: Despite the improved outcome in complete atrioventricular septal defect (AVSD) repair, reoperations for left atrioventricular valve (LAVV) dysfunction are common. The aim of this study was to evaluate the effect of fresh untreated autologous pericardium for ventricular septal defect (VSD) closure on atrioventricular valve function and compare the results with the use of treated bovine pericardial patch material. Methods: Clinical and echocardiographic data were collected of patients with complete AVSD with their VSD closed with either untreated autologous pericardial or treated bovine pericardial patch material between January 1, 1996, and December 31, 2003. Evaluation closed in September 2019. Results: A total of 77 patients were analyzed (untreated autologous pericardial VSD patch: 59 [77%], treated bovine pericardial VSD patch: 18 [23%]). Median age at surgery was 3.6 (interquartile range [IQR]: 2.7-4.5) months, and median weight was 4.5 (IQR: 3.9-5.1) kg. Trisomy 21 was present in 70 (91%) patients. Median follow-up time was 17.5 (IQR: 12.6-19.8) years. Death <30 days occurred in two (3%) patients. Reinterventions occurred in eight patients (early [within 30 days] in two, early and late in one, and late in five), all in the autologous pericardium group. Log-rank tests showed no significant difference in mortality (P =.892), LAVV reinterventions (P =.228), or LAVV regurgitation (P =.770). Conclusions: In AVSD, the VSD can safely be closed with either untreated autologous pericardium or xeno-pericardium. We found no difference in LAVV regurgitation or the need for reoperation between the two patches
Mechanical Mitral Valve Replacement:A Multicenter Study of Outcomes With Use of 15-to 17-mm Prostheses
Background. The aim of this study was to evaluate early and mid-term outcomes (mortality and prosthetic valve reintervention) after mitral valve replacement with 15- to 17-mm mechanical prostheses. Methods. A multicenter, retrospective cohort study was performed among patients who underwent mitral valve replacement with a 15- to 17-mm mechanical prosthesis at 6 congenital cardiac centers: 5 in The Netherlands and 1 in the United States. Baseline, operative, and follow-up data were evaluated. Results. Mitral valve replacement was performed in 61 infants (15 mm, n = 17 [28%]; 16 mm, n = 18 [29%]; 17 mm, n = 26 [43%]), of whom 27 (47%) were admitted to the intensive care unit before surgery and 22 (39%) required ventilator support. Median age at surgery was 5.9 months (interquartile range [IQR] 3.2-17.4), and median weight was 5.7 kg (IQR, 4.5-8.8). There were 13 in-hospital deaths (21%) and 8 late deaths (17%, among 48 hospital survivors). Major adverse events occurred in 34 (56%). Median follow-up was 4.0 years (IQR, 0.4-12.5) First prosthetic valve replacement (n = 27 [44%]) occurred at a median of 3.7 years (IQR, 1.9-6.8). Prosthetic valve endocarditis was not reported, and there was no mortality related to prosthesis replacement. Other reinterventions included permanent pacemaker implantation (n = 9 [15%]), subaortic stenosis resection (n = 4 [7%]), aortic valve repair (n = 3 [5%], and aortic valve replacement (n = 6 [10%]). Conclusions. Mitral valve replacement with 15- to 17-mm mechanical prostheses is an important alternative to save critically ill neonates and infants in whom the mitral valve cannot be repaired. Prosthesis replacement for outgrowth can be carried out with low risk. (C) 2020 by The Society of Thoracic Surgeons. Published by Elsevier Inc
Optimized Preoperative Planning of Double Outlet Right Ventricle Patients by 3D Printing and Virtual Reality:A Pilot Study
OBJECTIVES: In complex double outlet right ventricle (DORV) patients, the optimal surgical approach may be difficult to assess based on conventional two-dimensional (2D) ultrasound (US) and computed tomography (CT) imaging. The aim of this study is to assess the added value of 3D printed and 3D Virtual Reality (VR) models of the heart used for surgical planning in DORV patients, supplementary to the gold standard 2D imaging modalities.METHODS: Five patients with different DORV-subtypes and high-quality CT scans were selected retrospectively. 3D prints and 3D-VR models were created. Twelve congenital cardiac surgeons and paediatric cardiologists, from three different hospitals, were shown 2D-CT first, after which they assessed the 3D print and 3D-VR models in random order. After each imaging method, a questionnaire was filled in on the visibility of essential structures and the surgical plan.RESULTS: Spatial relationships were generally better visualized using 3D methods (3D printing/3D-VR) than in 2D. The feasibility of VSD patch closure could be determined best using 3D-VR reconstructions (3D-VR 92%, 3D print 66%, and US/CT 46%, P < 0.01). The percentage of proposed surgical plans corresponding to the performed surgical approach was 66% for plans based on US/CT, 78% for plans based on 3D printing, and 80% for plans based on 3D-VR visualization.CONCLUSIONS: This study shows that both 3D printing and 3D-VR have additional value for cardiac surgeons and cardiologists over 2D imaging, because of better visualization of spatial relationships. As a result, the proposed surgical plans based on the 3D visualizations matched the actual performed surgery to a greater extent.</p
Volumetric Computed Tomography Angiography in the Evaluation of Mediastinal Fluid Collections following Congenital Cardiac Surgery
We present 3 patients with 4 causes of mediastinal fluid collection after congenital cardiac surgery in this extended case report. Volumetric computed tomography played an essential role in diagnosing causes and extent, relevant to subsequent management. Recent advances in volumetric computed tomography allow fast and accurate imaging of cardiovascular and extravascular structures in children with acceptable radiation dose, providing a powerful imaging tool for the evaluation of complications after congenital cardiac surgery
Haemodynamic performance of 16–20-mm extracardiac Goretex conduits in adolescent Fontan patients at rest and during simulated exercise
OBJECTIVES: To date, it is not known if 16–20-mm extracardiac conduits are outgrown during somatic growth from childhood to adolescence. This study aims to determine total cavopulmonary connection (TCPC) haemodynamics in adolescent Fontan patients at rest and during simulated exercise and to assess the relationship between conduit size and haemodynamics. METHODS: Patient-specific, magnetic resonance imaging-based computational fluid dynamic models of the TCPC were performed in 51 extracardiac Fontan patients with 16–20-mm conduits. Power loss, pressure gradient and normalized resistance were quantified in rest and during simulated exercise. The cross-sectional area (CSA) (mean and minimum) of the vessels of the TCPC was determined and normalized for flow rate (mm2/l/min). Peak (predicted) oxygen uptake was assessed. RESULTS: The median age was 16.2 years (Q1–Q3 14.0–18.2). The normalized mean conduit CSA was 35–73% smaller compared to the inferior and superior vena cava, hepatic veins and left/right pulmonary artery (all P < 0.001). The median TCPC pressure gradient was 0.7 mmHg (Q1–Q3 0.5–0.8) and 2.0 (Q1–Q3 1.4–2.6) during rest and simulated exercise, respectively. A moderate–strong inverse nonlinear relationship was present between normalized mean conduit CSA and TCPC haemodynamics in rest and exercise. TCPC pressure gradients of >_1.0 at rest and >_3.0 mmHg during simulated exercise were observed in patients with a conduit CSA <_ 45 mm2/l/min and favourable haemodynamics (<1 mmHg during both rest and exercise) in conduits >_125 mm2/l/min. Normalized TCPC resistance correlated with (predicted) peak oxygen uptake. CONCLUSIONS: Extracardiac conduits of 16–20 mm have become relatively undersized in most adolescent Fontan patients leading to suboptimal haemodynamics.</p
Right ventricular function declines after cardiac surgery in adult patients with congenital heart disease
Right ventricular function (RVF) is often selectively declined after coronary artery bypass graft surgery. In adult patients with congenital heart disease (CHD) the incidence and persistence of declined RVF after cardiac surgery is unknown. The current study aimed to describe RVF after cardiac surgery in these patients. Adult CHD patients operated between January 2008 and December 2009 in the Academic Medical Centre in Amsterdam were studied. Clinical characteristics, laboratory tests, surgical data and intensive care unit outcome were obtained from medical records. RVF was measured by trans-thoracic echocardiography (TTE) and expressed by tricuspid annular plane systolic excursion (TAPSE), tissue Doppler imaging (RV S’) and myocardial performance index (MPI) pre-operatively and direct, at intermediate and late follow up. Of a total of 185 operated, 86 patients (mean age 39 ± 13 years, 54% male) had echo data available. There was a significant fall in RVF after cardiac surgery. TAPSE and RV S’ were significantly higher and MPI was significantly lower pre-operatively compared to direct post-operative values (TAPSE 22 ± 5 versus 13 ± 3 mm (P < 0.01), RV S’ 11 ± 4 versus 8 ± 2 cm/s (P < 0.01) and MPI 0.36 ± 0.14 vs 0.62 ± 0.25; P < 0.01). There were no significant differences in left ventricular function pre-operatively compared to post-operative values. Right-sided surgery was performed in 33, left-sided surgery in 37 and both sided surgery in 16 patients. Decline in RVF was equal for those groups. Patients with severe decline in RVF, were patients who underwent tricuspid valve surgery. Decline in RVF was associated with post-operative myocardial creatine kinase level and maximal troponin T level. There was no association between decline in RVF and clinical outcome on the intensive care unit. 18 months post-operatively, most RVF parameters had recovered to pre-operative values, but TAPSE which remained still lower (P < 0.01). CHD patients have a decline in RVF directly after cardiac surgery, regardless the side of surgery. Although a gradual improvement was observed, complete recovery was not seen 18 months post-operatively
A comprehensive analysis of the intramural segment in interarterial anomalous coronary arteries using computed tomography angiography
Aims An anomalous coronary artery originating from the opposite sinus of Valsalva (ACAOS) with an interarterial course can be assessed using computed tomography angiography (CTA) for the presence of high-risk characteristics associated with sudden cardiac death. These features include a slit-like ostium, acute angle take-off, proximal luminal narrowing, and an intramural segment. To date, no robust CTA criteria exist to determine the presence of an intramural segment. We aimed to deduct new CTA parameters to distinguish an intramural course of interarterial ACAOS. Methods Twenty-five patients with an interarterial ACAOS (64% female, mean age 46 years, 88% right ACAOS) from two aca- and results demic hospitals were evaluated. Inclusion criteria were the availability of a preoperative CTA scan (0.51 mm slice thickness) and peroperative confirmation of the intramural segment. Using multiplanar reconstruction of the CTA, the distance between the lumen of the aorta and the lumen of the ACAOS [defined as ‘interluminal space’ (ILS)] was assessed at 2 mm intervals along the intramural segment. Analysis showed a mean ILS of 0.69 + 0.15 mm at 2 mm from the ostium. At the end of the intramural segment where the ACAOS becomes non-intramural, the mean ILS was significantly larger (1.27 + 0.29 mm, P, 0.001). Interobserver agreement evaluation showed good reproducibility (intraclass correlation coefficient 0.77, P, 0.001). Receiver operator characteristic analysis demonstrated that at a cut-off ILS of,0.95 mm, an intramural segment can be diagnosed with 100% sensitivity and 84% specificity. Conclusion The ILS is introduced as a novel and robust CTA parameter to identify an intramural course of interarterial ACAOS. An ILS of,0.95 mm is indicative of an intramural segment
- …