3,033 research outputs found

    Signal and noise of Diamond Pixel Detectors at High Radiation Fluences

    Full text link
    CVD diamond is an attractive material option for LHC vertex detectors because of its strong radiation-hardness causal to its large band gap and strong lattice. In particular, pixel detectors operating close to the interaction point profit from tiny leakage currents and small pixel capacitances of diamond resulting in low noise figures when compared to silicon. On the other hand, the charge signal from traversing high energy particles is smaller in diamond than in silicon by a factor of about 2.2. Therefore, a quantitative determination of the signal-to-noise ratio (S/N) of diamond in comparison with silicon at fluences in excess of 1015^{15} neq_{eq} cm2^{-2}, which are expected for the LHC upgrade, is important. Based on measurements of irradiated diamond sensors and the FE-I4 pixel readout chip design, we determine the signal and the noise of diamond pixel detectors irradiated with high particle fluences. To characterize the effect of the radiation damage on the materials and the signal decrease, the change of the mean free path λe/h\lambda_{e/h} of the charge carriers is determined as a function of irradiation fluence. We make use of the FE-I4 pixel chip developed for ATLAS upgrades to realistically estimate the expected noise figures: the expected leakage current at a given fluence is taken from calibrated calculations and the pixel capacitance is measured using a purposely developed chip (PixCap). We compare the resulting S/N figures with those for planar silicon pixel detectors using published charge loss measurements and the same extrapolation methods as for diamond. It is shown that the expected S/N of a diamond pixel detector with pixel pitches typical for LHC, exceeds that of planar silicon pixels at fluences beyond 1015^{15} particles cm2^{-2}, the exact value only depending on the maximum operation voltage assumed for irradiated silicon pixel detectors

    Production and characterization of micro-size pores for ion track etching applications

    Get PDF
    For many years the applications of ion track etch materials have increased considerably, like charged particles detection, molecular identification with nanopores, ion track filters, magnetic studies with nanowires and so on. Over the materials generally used as track detector, the Poly-Allyl-Diglycol Carbonate (PADC), offers many advantages, like its nearly 100 % detection efficiency for charged particle, a high resistance to harsh environment, the lowest detection threshold, a high abrasion resistance and a low production costs. All of these properties have made it particularly attractive material, even if due to its brittleness, obtaining a thin film (less than 500 μm) is still a challenge. In this work, PADC foils have been exposed to a-particles emitted by a thin radioactive source of 241Am and to C ions from the Tandetron 4130 MC accelerator. The latent tracks generated in the polymer have been developed using a standard etching procedure in 6.25 NaOH solution. The dependence of the ion tracks' geometry on the ion beam energy and fluence has been evaluated combining the information obtained through a semiautomatic computer script that selects the etched ion tracks according to their diameter and mean grey value and nanometric resolution images by atomic force microscopy

    RBS, PIXE, Ion-Microbeam and SR-FTIR Analyses of Pottery Fragments from Azerbaijan

    Get PDF
    The present work is aimed at the investigation of the ceramic bulk and pigmented glazed surfaces of ancient potteries dating back to XIX century A.D. and coming from the charming archeological site located in the Medieval Agsu town (Azerbaijan), a geographic area of special interest due to the ancient commercial routes between China, Asia Minor, and Europe. For the purpose of the study, complementary investigation tools have been exploited: non-destructive or micro-destructive investigation at elemental level by ion beam analysis (IBA) techniques, by using Rutherford Backscattering Spectrometry (RBS), Proton-Induced X-ray Emission (PIXE) spectroscopy and ion-microbeam analysis, and chemical characterization at microscopic level, by means of synchrotron radiation (SR) Fourier transform infrared (FTIR) microspectroscopy. The acquired information reveals useful for the identification of the provenance, the reconstruction of the firing technology, and finally, the identification of the pigment was used as a colorant of the glaze

    Pion and proton showers in the CALICE scintillator-steel analogue hadron calorimeter

    Full text link
    Showers produced by positive hadrons in the highly granular CALICE scintillator-steel analogue hadron calorimeter were studied. The experimental data were collected at CERN and FNAL for single particles with initial momenta from 10 to 80 GeV/c. The calorimeter response and resolution and spatial characteristics of shower development for proton- and pion-induced showers for test beam data and simulations using Geant4 version 9.6 are compared.Comment: 26 pages, 16 figures, JINST style, changes in the author list, typos corrected, new section added, figures regrouped. Accepted for publication in JINS

    Performance of the first prototype of the CALICE scintillator strip electromagnetic calorimeter

    Get PDF
    A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45x10x3 mm3 plastic scintillator strips. Data were collected using a positron test beam at DESY with momenta between 1 and 6 GeV/c. The prototype's performance is presented in terms of the linearity and resolution of the energy measurement. These results represent an important milestone in the development of highly granular calorimeters using scintillator strip technology. This technology is being developed for a future linear collider experiment, aiming at the precise measurement of jet energies using particle flow techniques

    Calcification of intervertebral discs in the dachshund: a radiographic and histopathologic study of 20 dogs

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The purpose of the study was to compare radiographic and histopathologic findings with regard to number and extent of calcified discs in the dachshund.</p> <p>Methods</p> <p>The intervertebral discs of 20 dachshunds were subjected to a radiographic and histopathologic examination. The dogs were selected randomly from clinical cases euthanased for reasons unrelated to research at the Norwegian School of Veterinary Science. Lateral radiographs were taken of the vertebral columns after removing them from the carcasses. The histopathologic examination included 5 μm thick sections in the transverse plane, stained with hematoxylin-eosin and von Kossa. Radiographs and histological sections were evaluated independently.</p> <p>Results</p> <p>A total of 148 (28.5%) calcified discs were identified at the radiographic and 230 (45.7%) at the histopathologic examination. Of 92 discs found to be calcified by histopathology, but not by radiography, the degree of calcification was evaluated as 'slight' in 84 (91.3%). All the intervertebral discs (n = 138) that were found to be calcified by radiography were also found to be calcified by histopathology.</p> <p>Conclusion</p> <p>A sensitivity of 0.6 and specificity of 1.0 for radiography was calculated when using histopathology as the gold standard.</p

    Decision making in advanced heart failure: A scientific statement from the american heart association

    Get PDF
    Shared decision making for advanced heart failure has become both more challenging and more crucial as duration of disease and treatment options have increased. High-quality decisions are chosen from medically reasonable options and are aligned with values, goals, and preferences of an informed patient. The top 10 things to know about decision making in advanced heart failure care are listed in Table 1
    corecore