261 research outputs found

    Acute cell viability and nitric oxide release in lateral menisci following closed-joint knee injury in a lapine model of post-traumatic osteoarthritis

    Get PDF
    BACKGROUND: Traumatic impaction is known to cause acute cell death and macroscopic damage to cartilage and menisci in vitro. The purpose of this study was to investigate cell viability and macroscopic damage of the medial and lateral menisci using an in situ model of traumatic loading. Furthermore, the release of nitric oxide from meniscus, synovium, cartilage, and subchondral bone was also documented. METHODS: The left limbs of five rabbits were subjected to tibiofemoral impaction resulting in anterior cruciate ligament (ACL) rupture and meniscal damage. Meniscal tear morphology was assessed immediately after trauma and cell viability of the lateral and medial menisci was assessed 24 hrs post-injury. Nitric oxide (NO) released from joint tissues to the media was assayed at 12 and 24 hrs post injury. RESULTS: ACL and meniscal tearing resulted from the traumatic closed joint impact. A significant decrease in cell viability was observed in the lateral menisci following traumatic impaction compared to the medial menisci and control limbs. While NO release was greater in the impacted joints, this difference was not statistically significant. CONCLUSION: This is the first study to investigate acute meniscal viability following an in situ traumatic loading event that results in rupture of the ACL. The change in cell viability of the lateral menisci may play a role in the advancement of joint degeneration following traumatic knee joint injury. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/1471-2474-15-297) contains supplementary material, which is available to authorized users

    Meniscal tissue explants response depends on level of dynamic compressive strain

    Get PDF
    SummaryObjectiveFollowing partial meniscectomy, the remaining meniscus is exposed to an altered loading environment. In vitro 20% dynamic compressive strains on meniscal tissue explants has been shown to lead to an increase in release of glycosaminoglycans from the tissue and increased expression of interleukin-1α (IL-1α). The goal of this study was to determine if compressive loading which induces endogenously expressed IL-1 results in downstream changes in gene expression of anabolic and catabolic molecules in meniscal tissue, such as MMP expression.MethodRelative changes in gene expression of MMP-1, MMP-3, MMP-9, MMP-13, A Disintegrin and Metalloproteinase with ThromboSpondin 4 (ADAMTS4), ADAMTS5, TNFα, TGFβ, COX-2, Type I collagen (COL-1) and aggrecan and subsequent changes in the concentration of prostaglandin E2 released by meniscal tissue in response to varying levels of dynamic compression (0%, 10%, and 20%) were measured. Porcine meniscal explants were dynamically compressed for 2h at 1Hz.Results20% dynamic compressive strains upregulated MMP-1, MMP-3, MMP-13 and ADAMTS4 compared to no dynamic loading. Aggrecan, COX-2, and ADAMTS5 gene expression were upregulated under 10% strain compared to no dynamic loading while COL-1, TIMP-1, and TGFβ gene expression were not dependent on the magnitude of loading.ConclusionThis data suggests that changes in mechanical loading of the knee joint meniscus from 10% to 20% dynamic strain can increase the catabolic activity of the meniscus

    Annexin V disruption impairs mechanically induced calcium signaling in osteoblastic cells

    Get PDF
    Abstract The mechanical environment of the skeleton plays an important role in the establishment and maintenance of structurally competent bone. Biophysical signals induced by mechanical loading elicit a variety of cellular responses in bone cells, however, little is known about the underlying mechanotransduction mechanism. We hypothesized that bone cells detect and transduce biophysical signals into biological responses via a mechanism requiring annexin V (AnxV). AnxV, a calcium-dependent phospholipid binding protein, has several attributes, which suggest it is ideally suited for a role as a mechanosensor, possibly a mechanosensitive ion channel. These include the ability to function as a Ca 2+ selective ion channel, and the ability to interact with both extracellular matrix proteins and cytoskeletal elements. To test the hypothesis that AnxV has a role in mechanosensing, we studied the response of osteoblastic cells to oscillating fluid flow, a physiologically relevant physical signal in bone, in the presence and absence of AnxV inhibitors. In addition, we investigated the effects of oscillating flow on the cellular location of AnxV. Oscillating fluid flow increased both [Ca 2+ ] i levels and c-fos protein levels in osteoblasts. Disruption of AnxV with blocking antibodies or a pharmacological inhibitor, K201 (JTV-519), significantly inhibited both responses. Additionally, our data show that the cellular location of AnxV was modulated by oscillating fluid flow. Exposure to oscillating fluid flow resulted in a significant increase in AnxV at both the cell and nuclear membranes. In summary, our data suggest that AnxV mediates flow-induced Ca 2+ signaling in osteoblastic cells. These data support the idea of AnxV as a Ca 2+ channel, or a component of the signaling pathway, in the mechanism by which mechanical signals are transduced into cellular responses in the osteoblast. Furthermore, the presence of a highly mobile pool of AnxV may provide cells with a powerful mechanism by which cellular responses to mechanical loading might be amplified and regulated.

    Identification of Cross-Sectional Parameters of Lateral Meniscal Allografts That Predict Tibial Contact Pressure in Human Cadaveric Knees

    Get PDF
    To guide the development of improved procedures for selecting meniscal allografts, the objective of this study was to identify which cross-sectional parameters of a lateral menisca

    Osteochondral Grafting: Effect of Graft Alignment, Material Properties, and Articular Geometry

    Get PDF
    Osteochondral grafting for cartilage lesions is an attractive surgical procedure; however, the clinical results have not always been successful. Surgical recommendations differ with respect to donor site and graft placement technique. No clear biomechanical analysis of these surgical options has been reported. We hypothesized that differences in graft placement, graft biomechanical properties, and graft topography affect cartilage stresses and strains. A finite element model of articular cartilage and meniscus in a normal knee was constructed. The model was used to analyze the magnitude and the distribution of contact stresses, von Mises stresses, and compressive strains in the intact knee, after creation of an 8-mm diameter osteochondral defect, and after osteochondral grafting of the defect. The effects of graft placement, articular surface topography, and biomechanical properties were evaluated. The osteochondral defect generated minimal changes in peak contact stress (3.6 MPa) relative to the intact condition (3.4 MPa) but significantly increased peak von Mises stress (by 110%) and peak compressive strain (by 63%). A perfectly matched graft restored stresses and strains to near intact conditions. Leaving the graft proud by 0.5 mm generated the greatest increase in local stresses (peak contact stresses = 6.7 MPa). Reducing graft stiffness and curvature of articular surface had lesser effects on local stresses. Graft alignment, graft biomechanical properties, and graft topography all affected cartilage stresses and strains. Contact stresses, von Mises stresses, and compressive strains are biomechanical markers for potential tissue damage and cell death. Leaving the graft proud tends to jeopardize the graft by increasing the stresses and strains on the graft. From a biomechanical perspective, the ideal surgical procedure is a perfectly aligned graft with reasonably matched articular cartilage surface from a lower load-bearing region of the knee

    Deficiency of annexins A5 and A6 induces complex changes in the transcriptome of growth plate cartilage but does not inhibit the induction of mineralization

    Get PDF
    Initiation of mineralization during endochondral ossification is a multistep process and has been assumed to correlate with specific interactions of annexins A5 and A6 and collagens. However, skeletal development appears to be normal in mice deficient for either A5 or A6, and the highly conserved structures led to the assumption that A5 and A6 may fulfill redundant functions. We have now generated mice deficient of both proteins. These mice were viable and fertile and showed no obvious abnormalities. Assessment of skeletal elements using histologic, ultrastructural, and peripheral quantitative computed tomographic methods revealed that mineralization and development of the skeleton were not significantly affected in mutant mice. Otherwise, global gene expression analysis showed subtle changes at the transcriptome level of genes involved in cell growth and intermediate metabolism. These results indicate that annexins A5 and A6 may not represent the essential annexins that promote mineralization in vivo

    Custom-designed orthopedic implants evaluated using finite element analysis of patient-specific computed tomography data: femoral-component case study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Conventional knee and hip implant systems have been in use for many years with good success. However, the custom design of implant components based on patient-specific anatomy has been attempted to overcome existing shortcomings of current designs. The longevity of cementless implant components is highly dependent on the initial fit between the bone surface and the implant. The bone-implant interface design has historically been limited by the surgical tools and cutting guides available; and the cost of fabricating custom-designed implant components has been prohibitive.</p> <p>Methods</p> <p>This paper describes an approach where the custom design is based on a Computed Tomography scan of the patient's joint. The proposed design will customize both the articulating surface and the bone-implant interface to address the most common problems found with conventional knee-implant components. Finite Element Analysis is used to evaluate and compare the proposed design of a custom femoral component with a conventional design.</p> <p>Results</p> <p>The proposed design shows a more even stress distribution on the bone-implant interface surface, which will reduce the uneven bone remodeling that can lead to premature loosening.</p> <p>Conclusion</p> <p>The proposed custom femoral component design has the following advantages compared with a conventional femoral component. (i) Since the articulating surface closely mimics the shape of the distal femur, there is no need for resurfacing of the patella or gait change. (ii) Owing to the resulting stress distribution, bone remodeling is even and the risk of premature loosening might be reduced. (iii) Because the bone-implant interface can accommodate anatomical abnormalities at the distal femur, the need for surgical interventions and fitting of filler components is reduced. (iv) Given that the bone-implant interface is customized, about 40% less bone must be removed. The primary disadvantages are the time and cost required for the design and the possible need for a surgical robot to perform the bone resection. Some of these disadvantages may be eliminated by the use of rapid prototyping technologies, especially the use of Electron Beam Melting technology for quick and economical fabrication of custom implant components.</p

    Proteoglycan Breakdown of Meniscal Explants Following Dynamic Compression Using a Novel Bioreactor

    Get PDF
    Motivated by our interest in examining meniscal mechanotransduction processes, we report on the validation of a new tissue engineering bioreactor. This paper describes the design and performance capabilities of a tissue engineering bioreactor for cyclic compression of meniscal explants. We showed that the system maintains a tissue culture environment equivalent to that provided by conventional incubators and that its strain output was uniform and reproducible. The system incorporates a linear actuator and load cell aligned together in a frame that is contained within an incubator and allows for large loads and small displacements. A plunger with six Teflon-filled Delrin compression rods is attached to the actuator compressing up to six tissue explants simultaneously and with even pressure. The bioreactor system was used to study proteoglycan (PG) breakdown in porcine meniscal explants following various input loading tests (0–20% strain, 0–0.1 MPa). The greatest PG breakdown was measured following 20% compressive strain. These strain and stress levels have been shown to correspond to partial meniscectomy. Thus, these data suggest that removing 30–60% of meniscal tissue will result in the breakdown of meniscal tissue proteoglycans

    IL-1 and iNOS gene expression and NO synthesis in the superior region of meniscal explants are dependent on the magnitude of compressive strains

    Get PDF
    OBJECTIVE: Partial meniscectomy is known to cause osteoarthritis (OA) of the underlying cartilage as well as alter the load on the remaining meniscus. Removal of 30-60% of the medial meniscus increases compressive strains from a maximum of approximately 10% to almost 20%. The goal of this study is to determine if meniscal cells produce catabolic molecules in response to the altered loading that results from a partial meniscectomy. METHOD: Relative changes in gene expression of interleukin-1 (IL-1), inducible nitric oxide synthase (iNOS) and subsequent changes in the concentration of nitric oxide (NO) released by meniscal tissue in response to compression were measured. Porcine meniscal explants were dynamically compressed for 2 h at 1 Hz to simulate physiological stimulation at either 10% strain or 0.05 MPa stress. Additional explants were pathologically stimulated to either 0% strain, 20% strain or, 0.1 MPa stress. RESULTS: iNOS and IL-1 gene expression and NO release into the surrounding media were increased at 20% compressive strain compared to other conditions. Pathological unloading (0% compressive strain) of meniscal explants did not significantly change expression of IL-1 or iNOS genes, but did result in an increased amount of NO released compared to physiological strain of 10%. CONCLUSION: These data suggest that meniscectomies which reduce the surface area of the meniscus by 30-60% will increase the catabolic activity of the meniscus which may contribute to the progression of OA
    corecore