132 research outputs found

    A study of recurrent themes in the art of alcohol and drug dependent individuals in art therapy groups at a medical detoxification centre

    Get PDF
    This qualitative study uses an existing body of data derived from weekly art therapy groups conducted as part of a treatment programme at a medical detoxification facility. The design for this study relies on phenomenological and heuristic model of research. Previous art therapy researchers have suggested the recurrence of themes in the art work of particular client groups. This study examines themes previously observed in the art of substance abusers which are also present in the current data as well as additional themes that emerged in this study. These additional themes include the sun, the island paradise, the journey, cross roads and split-self images. These themes are examined in the light of a number of therapeutic models for change and in terms of the myth of the hero journey. An outline is proposed for a series of groups based on the hero’s journey to be used with substance misusers in recovery. Identifying the characteristics of the work produced by substance abusers in the early stages of their recoveries can be valuable aid for those who work with such clients in art therapy or substance use counselling. The images produced may give some indication of the client’s progress and in turn an indication of how effective the intervention strategies have been

    Development of an Animal Experimental Model for a Bileaflet Mechanical Heart Valve Prosthesis

    Get PDF
    The objective of this study was to develop a pre-clinical large animal model for the in vivo hemodynamic testing of prosthetic valves in the aortic position without the need for cardiopulmonary bypass. Ten male pigs were used. A composite valved conduit was constructed in the operating room by implanting a prosthetic valve between two separate pieces of vascular conduits, which bypassed the ascending aorta to the descending aorta. Prior to applying a side-biting clamp to the ascending aorta for proximal grafting to the aortic anastomosis, an aorta to femoral artery shunt was placed just proximally to this clamp. The heart rate, cardiac output, Vmax, transvalvular pressure gradient, effective orifice area and incremental dobutamine stress response were assessed. A dose dependant increase with dobutamine was seen in terms of cardiac output, Vmax, and the peak transvalvular pressure gradient both in the native and in the prosthetic valve. However, the increment was much steeper in the prosthetic valve. No significant differences in cardiac output were noted between the native and the prosthetic valves. The described pre-clinical porcine model was found suitable for site-specific in-vivo hemodynamic assessment of aortic valvular prosthesis without cardiopulmonary bypass

    Prosthetic heart valve evaluation by magnetic resonance imaging

    Get PDF
    Objective: To evaluate the potential of magnetic resonance imaging (MRI) for evaluation of velocity fields downstream of prosthetic aortic valves. Furthermore, to provide comparative data from bileaflet aortic valve prostheses in vitro and in patients. Methods: A pulsatile flow loop was set up in a 7.0 Tesla MRI scanner to study fluid velocity data downstream of a 25 mm aortic bileaflet heart valve prosthesis. Three dimensional surface plots of velocity fields were displayed. In six NYHA class I patients blood velocity profiles were studied downstream of their St. Jude Medical aortic valves using a 1.5 Tesla MRI whole-body scanner. Blood velocity data were displayed as mentioned above. Results: Fluid velocity profiles obtained from in vitro studies 0.25 valve diameter downstream of the valve exhibited significant details about the cross sectional distribution of fluid velocities. This distribution completely reflected the valve design. Blood velocity profiles in humans were considerably smoother and in some cases skewed with the highest velocities toward the anterior-right ascending aortic wall. Conclusion: Display and interpretation of fluid and blood velocity data obtained downstream of prosthetic valves is feasible both in vitro and in vivo using the MRI technique. An in vitro model with a straight tube and the test valve oriented orthogonally to the long axis of the test tube does not entail fluid velocity profiles which are compatible to those obtained from humans, probably due to the much more complex human geometry, and variable alignment of the valve with the ascending aorta. With the steadily improving quality of MRI scanners this technique has significant potential for comparative in vitro and in vivo hemodynamic evaluation of heart valve

    Chordal force distribution determines systolic mitral leaflet configuration and severity of functional mitral regurgitation

    Get PDF
    AbstractOBJECTIVESThe purpose of this study was to investigate the impact of the chordae tendineae force distribution on systolic mitral leaflet geometry and mitral valve competence invitro.BACKGROUNDFunctional mitral regurgitation is caused by changes in several elements of the valve apparatus. Interaction among these have to comply with the chordal forcedistribution defined by the chordal coapting forces (FC) created by the transmitral pressure difference, which close the leaflets and the chordal tethering forces(FT) pulling the leaflets apart.METHODSPorcine mitral valves (n = 5) were mounted in a left ventricular model where leading edge chordal forces measured by dedicated miniature force transducers werecontrolled by changing left ventricular pressure and papillary muscle position. Chordae geometry and occlusional leaflet area (OLA) needed to cover the leaflet orifice for a givenleaflet configuration were determined by two-dimensional echo and reconstructed three-dimensionally. Occlusional leaflet area was used as expression for incomplete leafletcoaptation. Regurgitant fraction (RF) was measured with an electromagnetic flowmeter.RESULTSMixed procedure statistics revealed a linear correlation between the sum of the chordal net forces, ∑[FC−FT]s, and OLA with regression coefficient (minimum − maximum) beta = −115 to −65 [mm2/N]; p< 0.001 and RF (beta = −0.06 to −0.01 [%/N]; p < 0.001). Increasing FTby papillary muscle malalignment restrictedleaflet mobility, resulting in a tented leaflet configuration due to an apical and posterior shift of the coaptation line. Anterior leaflet coapting forces increased due to mitralleaflet remodeling, which generated a nonuniform regurgitant orifice area.CONCLUSIONSAltered chordal force distribution caused functional mitral regurgitation based on tented leaflet configuration as observed clinically

    Subcoronary versus supracoronary aortic stenosis. an experimental evaluation

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Valvular aortic stenosis is the most common cause of left ventricular hypertrophy due to gradually increasing pressure work. As the stenosis develop the left ventricular hypertrophy may lead to congestive heart failure, increased risk of perioperative complications and also increased risk of sudden death. A functional porcine model imitating the pathophysiological nature of valvular aortic stenosis is very much sought after in order to study the geometrical and pathophysiological changes of the left ventricle, timing of surgery and also pharmacological therapy in this patient group.</p> <p>Earlier we developed a porcine model for aortic stenosis based on supracoronary aortic banding, this model may not completely imitate the pathophysiological changes that occurs when valvular aortic stenosis is present including the coronary blood flow. It would therefore be desirable to optimize this model according to the localization of the stenosis.</p> <p>Methods</p> <p>In 20 kg pigs subcoronary (n = 8), supracoronary aortic banding (n = 8) or sham operation (n = 4) was preformed via a left lateral thoracotomy. The primary endpoint was left ventricular wall thickness; secondary endpoints were heart/body weight ratio and the systolic/diastolic blood flow ratio in the left anterior descending coronary. Statistical evaluation by oneway anova and unpaired t-test.</p> <p>Results</p> <p>Sub- and supracoronary banding induce an equal degree of left ventricular hypertrophy compared with the control group. The coronary blood flow ratio was slightly but not significantly higher in the supracoronary group (ratio = 0.45) compared with the two other groups (subcoronary ratio = 0.36, control ratio = 0.34).</p> <p>Conclusions</p> <p>A human pathophysiologically compatible porcine model for valvular aortic stenosis was developed by performing subcoronary aortic banding. Sub- and supracoronary aortic banding induce an equal degree of left ventricular hypertrophy. This model may be valid for experimental investigations of aortic valve stenosis but studies of left ventricular hypertrophy can be studied equally well by graduated constriction of the ascending aorta.</p

    Evaluation of an electronic warfarin nomogram for anticoagulation of hemodialysis patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Warfarin nomograms to guide dosing have been shown to improve control of the international normalized ratio (INR) in the general outpatient setting. However, the effectiveness of these nomograms in hemodialysis patients is unknown. We evaluated the effectiveness of anticoagulation using an electronic warfarin nomogram administered by nurses in outpatient hemodialysis patients, compared to physician directed therapy.</p> <p>Methods</p> <p>Hemodialysis patients at any of the six outpatient clinics in Calgary, Alberta, treated with warfarin anticoagulation were included. Two five-month time periods were compared: prior to and post implementation of the nomogram. The primary endpoint was adequacy of anticoagulation (proportion of INR measurements within range ± 0.5 units).</p> <p>Results</p> <p>Overall, 67 patients were included in the pre- and 55 in the post-period (with 40 patients in both periods). Using generalized linear mixed models, the adequacy of INR control was similar in both periods for all range INR levels: in detail, range INR 1.5 to 2.5 (pre 93.6% (95% CI: 88.6% - 96.5%); post 95.6% (95% CI: 89.4% - 98.3%); p = 0.95); INR 2.0 to 3.0 (pre 82.2% (95% CI: 77.9% - 85.8%); post 77.4% (95% CI: 72.0% - 82.0%); p = 0.20); and, INR 2.5 to 3.5 (pre 84.3% (95% CI: 59.4% - 95.1%); post 66.8% (95% CI: 39.9% - 86.0%); p = 0.29). The mean number of INR measurements per patient decreased significantly between the pre- (30.5, 95% CI: 27.0 - 34.0) and post- (22.3, 95% CI: 18.4 - 26.1) (p = 0.003) period. There were 3 bleeding events in each of the periods.</p> <p>Conclusions</p> <p>An electronic warfarin anticoagulation nomogram administered by nurses achieved INR control similar to that of physician directed therapy among hemodialysis patients in an outpatient setting, with a significant reduction in frequency of testing. Future controlled trials are required to confirm the efficacy of this nomogram.</p
    corecore