33 research outputs found

    Influence of Finishing/Polishing Procedures on the Surface Texture of Two Resin Composites

    Get PDF
    This study compared surface roughness and gloss produced by different finishing/polishing procedures for two resin composites, Clearfil AP-X (AP-X) and Estelite Σ (ES). A total of 70 composite discs (n=35 for each resin composite) were prepared and divided at random into seven finishing/polishing groups (n=5): glass-pressed control; using a super-fine-grit diamond bur (SF); using CompoMaster (CM) after SF-finishing (SF+CM); using White Point (WP) after SF-finishing (SF+WP); using CM after SF+WP-finishing (SF+WP+CM); using Stainbuster (SB) after SF-finishing (SF+SB); and using CM after SF+SB-finishing (SF+SB+CM). After the finishing/polishing procedures, average surface roughness (Ra) and surface gloss (Gs(60°)) of all specimens were assessed with a surface profilometer and specimen gloss meter, respectively. Glass-pressed controls for both AP-X and ES composites showed the best surface finish in terms of both Ra and Gs(60°). SF-finishing produced the roughest surface and led to almost complete loss of gloss. While additional polishing with CM reduced Ra and increased Gs(60°), the additional finishing effect of WP or SB between SF-finishing and CM-polishing was not found for either AP-X or ES

    Combined use of baking soda and electric toothbrushing for removal of artificial extrinsic stain on enamel surface : an in vitro study

    Get PDF
    This study aimed to investigate the combined effect of baking soda and electric toothbrushing on the removal of artificial extrinsic stain in vitro. Material and Methods: Flat enamel surfaces of 15 bovine incisors were artificially stained

    Combined effects of electric toothbrushing and dentifrice on artificial stain removal : an in vitro study

    Get PDF
    This in vitro study aimed to clarify the combined effect of electric toothbrushing and dentifrice on the removal of artificial stain. Twenty-five bovine incisors were cut at the cervix and the crown was embedded in auto-cured acrylic resin. Specimens were abraded using #240 SiC paper to obtain a flat enamel surface, and 20 specimens were treated with 10% citric acid / 3% ferric chloride solution followed by 1% tannic acid solution to produce surface staining. They were divided into four groups: 1) brushing with an electric toothbrush and whitening dentifrice (group S+B); 2) brushing with an electric toothbrush and fluoride dentifrice (group S+C); 3) brushing with an electric toothbrush and no dentifrice (group S); and 4) no brushing (control group). The remaining five specimens were used as a baseline. Color values (L*, a*, and b* were measured before brushing (0 min), and at 1 min, 5 min, 10 min, and 20 min using a microscopic area spectrophotometer. The color change (?E) was calculated by subtracting the baseline values from the final color values obtained at each time point. The data were statistically analyzed using two-way repeated-measures analysis of variance and Tukey?s honest significant difference test as a post hoc test (p0.05). Groups S+B and S+C demonstrated greater ?E values than group S. The combination of electric toothbrushing and dentifrice removed the artificial stain more effectively than brushing without dentifrice. However, the stain removal was limited. The two dentifrices evaluated in this study exhibited similar stain removal effects

    Effect of Emitted Wavelength and Light Guide Type on Irradiance Discrepancies in Hand-Held Dental Curing Radiometers

    Get PDF
    The purpose of this study was to determine any discrepancies in the outputs of five commercial dental radiometers and also to evaluate the accuracy of these devices using a laboratory-grade spectroradiometer. The power densities of 12 different curing light sources were repeatedly measured for a total of five times using each radiometer in a random order. The emission spectra of all of the curing light sources were also measured using the spectroradiometer, and the integral value of each spectrum was calculated to determine the genuine power densities, which were then compared to the displayed power densities measured by the dental radiometers. The displayed values of power density were various and were dependent on the brand of radiometer, and this may be because each radiometer has a different wavelength sensitivity. These results cast doubt upon the accuracy of commercially available dental radiometers

    Effect of professional dental prophylaxis on the surface gloss and roughness of CAD/CAM restorative materials

    Get PDF
    This study aimed to evaluate the effect of dental prophylaxis on the surface gloss and roughness of different indirect restorative materials for computer-aided design/computer-aided manufacturing (CAD/CAM): two types of CAD/CAM composite resin blocks (Shofu Block HC and Estelite Block) and two types of CAD/CAM ceramic blocks (IPS Empress CAD and Celtra DUO). After polishing the CAD/CAM blocks and applying prophylaxis pastes, professional dental prophylaxis was performed using four different experimental protocols (n = 5 each): mechanical cleaning with Merssage Regular for 10 s four times (Group 1); four cycles of mechanical cleaning with Merssage Regular for 10 s and Merssage Fine for 10 s (Group 2); four cycles of mechanical cleaning with Merssage Regular for 10 s and Merssage Fine for 30 s (Group 3); and mechanical cleaning with Merssage Fine for 10 s four times (Group 4). A glossmeter was used to measure surface gloss before and after mechanical cleaning, and a contact stylus profilometer was used to measure surface roughness (Ra). Polishing with prophylactic paste led to a significant reduction in surface gloss and increase in surface roughness among resin composite blocks, whereas the polishing-related change in surface gloss or roughness was smaller in Celtra DUO, a zirconia-reinforced lithium silicate block. Changes in surface gloss and roughness due to polishing with a prophylactic paste containing large particles were not improved by subsequent polishing with a prophylactic paste containing fine particles

    Influence of solvent evaporation on ultimate tensile strength of contemporary dental adhesives

    Get PDF
    The aim of this study was to evaluate the influence of solvent evaporation on the ultimate tensile strength (UTS) of commercial adhesives. Two 1-step(OptiBond All-In-One and G-Premio Bond) and two 2-step (Clearfil SE Protect, OptiBond XTR) adhesives were selected. Two bottles of eachadhesive were opened and stored at 37 °C in a dry oven with silica gelshielded from light for 2 weeks (“Desiccated”). Two unopened bottles were stored at room temperature (“Original”). After 2 weeks, the adhesives were used to fill an hour-glass shaped, metallic matrix mold and light-cured. Samples were weighed, and then immersed in a 37 °C water bath for 1 h or 7 days. The UTS of each sample was then measured at a cross-head speed of 1 mm/min (n = 10). The UTS for the Clearfil SE Protect was higher in the“Original” than “Desiccated” samples (p  0.05). Neither of the two “Original” 1-step samples could be hardened, even after light-curing, yet the ‘Desiccated’ OptiBond All-In-One samples obtained high UTS values. Both OptiBond All-In-One and Clearfil SE Protect had an increase in weight after the 7-day immersion in water. In conclusion, residual solvent reduces the mechanical strength of the adhesive. The hydrophilicity of the adhesive resin might also affect its mechanical strength

    Influence of handpiece maintenance sprays on resin bonding to dentin

    No full text
    Toyotarou Sugawara1, Atsushi Kameyama2, Akiko Haruyama3, Takumi Oishi4, Nobuyuki Kukidome2, Yasuaki Takase2, Masatake Tsunoda21Undergraduate Student, Tokyo Dental College, Chiba, Japan; 2Division of General Dentistry, Tokyo Dental College Chiba Hospital, Chiba, Japan; 3Department of Dental Materials Science, Tokyo Dental College, Chiba, Japan; 4Department of Dentistry and Oral Surgery, Keio University School of Medicine, Tokyo, JapanObjective: To investigate the influence of maintenance spray on resin bonding to dentin.Materials and methods: The crown of extracted, caries-free human molars was transversally sectioned with a model trimmer to prepare the dentin surfaces from mid-coronal sound dentin, and then uniformly abraded with #600 silicon carbide paper. The dentin surfaces were randomly divided into three groups: oil-free spray group where maintenance cleaner for air bearing handpieces was sprayed onto the dentin surface for 1 s and rinsed with water spray for 30 s; oil-containing spray group where maintenance cleaner for micro motor handpieces was sprayed onto the dentin surface for 1 s and rinsed with water spray for 30 s; and control group where the surface was rinsed with water spray for 30 s and then air-dried. These surfaces were then bonded with Clearfil SE Bond (Kuraray Medical), and resin composite (Clearfil AP-X, Kuraray Medical) build-up crowns were incrementally constructed on the bonded surfaces. After storage for 24 h in 37°C water, the bonded teeth were sectioned into hour-glass shaped slices (0.7-mm thick) perpendicular to the bonded surfaces. The specimens were then subjected to microtensile bond strength (μTBS) testing at a crosshead speed of 1.0 mm/min. Data were analyzed with one-way ANOVA and the Tukey-Kramer test.Results: Maintenance spray-contaminated specimens (oil-free and oil-containing spray groups) showed significantly lower μTBS than control specimens (P < 0.05). However, there was no significant difference between the spray-contaminated groups (P > 0.05).Conclusion: Maintenance spray significantly reduces the bond strength of Clearfil SE Bond to dentin.Keywords: microtensile bond strength, lubricant, maintenance spray, contamination, dentin bondin
    corecore