561 research outputs found

    Measurement of the cosmic ray spectrum above 4×10184{\times}10^{18} eV using inclined events detected with the Pierre Auger Observatory

    Full text link
    A measurement of the cosmic-ray spectrum for energies exceeding 4×10184{\times}10^{18} eV is presented, which is based on the analysis of showers with zenith angles greater than 6060^{\circ} detected with the Pierre Auger Observatory between 1 January 2004 and 31 December 2013. The measured spectrum confirms a flux suppression at the highest energies. Above 5.3×10185.3{\times}10^{18} eV, the "ankle", the flux can be described by a power law EγE^{-\gamma} with index γ=2.70±0.02(stat)±0.1(sys)\gamma=2.70 \pm 0.02 \,\text{(stat)} \pm 0.1\,\text{(sys)} followed by a smooth suppression region. For the energy (EsE_\text{s}) at which the spectral flux has fallen to one-half of its extrapolated value in the absence of suppression, we find Es=(5.12±0.25(stat)1.2+1.0(sys))×1019E_\text{s}=(5.12\pm0.25\,\text{(stat)}^{+1.0}_{-1.2}\,\text{(sys)}){\times}10^{19} eV.Comment: Replaced with published version. Added journal reference and DO

    Energy Estimation of Cosmic Rays with the Engineering Radio Array of the Pierre Auger Observatory

    Full text link
    The Auger Engineering Radio Array (AERA) is part of the Pierre Auger Observatory and is used to detect the radio emission of cosmic-ray air showers. These observations are compared to the data of the surface detector stations of the Observatory, which provide well-calibrated information on the cosmic-ray energies and arrival directions. The response of the radio stations in the 30 to 80 MHz regime has been thoroughly calibrated to enable the reconstruction of the incoming electric field. For the latter, the energy deposit per area is determined from the radio pulses at each observer position and is interpolated using a two-dimensional function that takes into account signal asymmetries due to interference between the geomagnetic and charge-excess emission components. The spatial integral over the signal distribution gives a direct measurement of the energy transferred from the primary cosmic ray into radio emission in the AERA frequency range. We measure 15.8 MeV of radiation energy for a 1 EeV air shower arriving perpendicularly to the geomagnetic field. This radiation energy -- corrected for geometrical effects -- is used as a cosmic-ray energy estimator. Performing an absolute energy calibration against the surface-detector information, we observe that this radio-energy estimator scales quadratically with the cosmic-ray energy as expected for coherent emission. We find an energy resolution of the radio reconstruction of 22% for the data set and 17% for a high-quality subset containing only events with at least five radio stations with signal.Comment: Replaced with published version. Added journal reference and DO

    Measurement of the Radiation Energy in the Radio Signal of Extensive Air Showers as a Universal Estimator of Cosmic-Ray Energy

    Full text link
    We measure the energy emitted by extensive air showers in the form of radio emission in the frequency range from 30 to 80 MHz. Exploiting the accurate energy scale of the Pierre Auger Observatory, we obtain a radiation energy of 15.8 \pm 0.7 (stat) \pm 6.7 (sys) MeV for cosmic rays with an energy of 1 EeV arriving perpendicularly to a geomagnetic field of 0.24 G, scaling quadratically with the cosmic-ray energy. A comparison with predictions from state-of-the-art first-principle calculations shows agreement with our measurement. The radiation energy provides direct access to the calorimetric energy in the electromagnetic cascade of extensive air showers. Comparison with our result thus allows the direct calibration of any cosmic-ray radio detector against the well-established energy scale of the Pierre Auger Observatory.Comment: Replaced with published version. Added journal reference and DOI. Supplemental material in the ancillary file

    Standard diametric versus volumetric early tumor shrinkage as a predictor of survival in metastatic colorectal cancer : subgroup findings of the randomized, open-label phase III trial FIRE-3 / AIO KRK-0306

    Get PDF
    Objectives: Early tumor shrinkage (ETS) quantifies the objective response at the first assessment during systemic treatment. In metastatic colorectal cancer (mCRC), ETS gains relevance as an early available surrogate for patient survival. The aim of this study was to increase the predictive accuracy of ETS by using semi-automated volumetry instead of standard diametric measurements. Methods: Diametric and volumetric ETS were retrospectively calculated in 253 mCRC patients who received 5-fluorouracil, leucovorin, and irinotecan (FOLFIRI) combined with either cetuximab or bevacizumab. The association of diametric and volumetric ETS with overall survival (OS) and progression-free survival (PFS) was compared. Result:s Continuous diametric and volumetric ETS predicted survival similarly regarding concordance indices (p > .05). In receiver operating characteristics, a volumetric threshold of 45% optimally identified short-term survivors. For patients with volumetric ETS ≥ 45% (vs < 45%), median OS was longer (32.5 vs 19.0 months, p < .001) and the risk of death reduced for the first and second year (hazard ratio [HR] = 0.25, p < .001, and HR = 0.39, p < .001). Patients with ETS ≥ 45%had a reduced risk of progressive disease only for the first 6 months (HR = 0.26, p < .001). These survival times and risks were comparable to those of diametric ETS ≥ 20% (vs < 20%). Conclusions: The accuracy of ETS in predicting survival was not increased by volumetric instead of diametric measurements. Continuous diametric and volumetric ETS similarly predicted survival, regardless of whether patients received cetuximab or bevacizumab. A volumetric ETS threshold of 45%and a diametric ETS threshold of 20%equally identified short-term survivors.peer-reviewe

    Preventive medicine of von Hippel-Lindau disease-associated pancreatic neuroendocrine tumors

    Get PDF
    Pancreatic neuroendocrine tumors (PanNETs) are rare in von Hippel-Lindau disease (VHL) but cause serious morbidity and mortality. Management guidelines for VHL-PanNETs continue to be based on limited evidence, and survival data to guide surgical management are lacking. We established the European-American-Asian-VHL-PanNET-Registry to assess data for risks for metastases, survival and long-term outcomes to provide best management recommendations. Of 2330 VHL patients, 273 had a total of 484 PanNETs. Median age at diagnosis of PanNET was 35 years (range 10-75). Fifty-five (20%) patients had metastatic PanNETs. Metastatic PanNETs were significantly larger (median size 5 vs 2\u2009cm; P\u20091.5\u2009cm in diameter were operated. Ten-year survival was significantly longer in operated vs non-operated patients, in particular for PanNETs <2.8\u2009cm vs 652.8\u2009cm (94% vs 85% by 10 years; P\u2009=\u20090.020; 80% vs 50% at 10 years; P\u2009=\u20090.030). This study demonstrates that patients with PanNET approaching the cut-off diameter of 2.8\u2009cm should be operated. Mutations in exon 3, especially of codons 161/167 are at enhanced risk for metastatic PanNETs. Survival is significantly longer in operated non-metastatic VHL-PanNETs

    Infectious diseases in allogeneic haematopoietic stem cell transplantation: prevention and prophylaxis strategy guidelines 2016

    Get PDF
    corecore