20,285 research outputs found
Study made of corrosion resistance of stainless steel and nickel alloys in nuclear reactor superheaters
Experiments performed under conditions found in nuclear reactor superheaters determine the corrosion rate of stainless steel and nickel alloys used in them. Electropolishing was the primary surface treatment before the corrosion test. Corrosion is determined by weight loss of specimens after defilming
The monopole mass in the three-dimensional Georgi-Glashow model
We study the three-dimensional Georgi-Glashow model to demonstrate how
magnetic monopoles can be studied fully non-perturbatively in lattice Monte
Carlo simulations, without any assumptions about the smoothness of the field
configurations. We examine the apparent contradiction between the conjectured
analytic connection of the `broken' and `symmetric' phases, and the
interpretation of the mass (i.e., the free energy) of the fully quantised 't
Hooft-Polyakov monopole as an order parameter to distinguish the phases. We use
Monte Carlo simulations to measure the monopole free energy and its first
derivative with respect to the scalar mass. On small volumes we compare this to
semi-classical predictions for the monopole. On large volumes we show that the
free energy is screened to zero, signalling the formation of a confining
monopole condensate. This screening does not allow the monopole mass to be
interpreted as an order parameter, resolving the paradox.Comment: 12 pages, 7 figures, uses revtex. Minor changes made to the text to
match with the published version at
http://link.aps.org/abstract/PRD/v65/e12500
Electronic Structure of Cu_(1-x)Ni_xRh_2S_4 and CuRh_2Se_4: Band Structure Calculations, X-ray Photoemission and Fluorescence Measurements
The electronic structure of spinel-type Cu_(1-x)Ni_xRh_2S_4 (x = 0.0, 0.1,
0.3, 0.5, 1.0) and CuRh_2Se_4 compounds has been studied by means of X-ray
photoelectron and fluorescent spectroscopy. Cu L_3, Ni L_3, S L_(2,3) and Se
M_(2,3) X-ray emission spectra (XES) were measured near thresholds at Beamline
8.0 of the Lawrence Berkeley Laboratory's Advanced Light Source. XES
measurements of the constituent atoms of these compounds, reduced to the same
binding energy scale, are found to be in excellent agreement with XPS valence
bands. The calculated XES spectra which include dipole matrix elements show
that the partial density of states reproduce experimental spectra quite well.
States near the Fermi level (E_F) have strong Rh d and S(Se) p character in all
compounds. In NiRh_2S_4 the Ni 3d states contribute strongly at E_F, whereas in
both Cu compounds the Cu 3d bands are only ~1 eV wide and centered ~2.5 eV
below E_F, leaving very little 3d character at E_F. The density of states at
the Fermi level is less in NiRh_2S_4 than in CuRh_2S_4. This difference may
contribute to the observed decrease, as a function of Ni concentration, in the
superconducting transition temperature in Cu_(1-x)Ni_xRh_2S_4. The density of
states of the ordered alloy Cu_(1/2)Ni_(1/2)Rh_2S_4 shows behavior that is more
``split-band''-like than ``rigid band''-like.Comment: 7 pages of text, 11 trailing figures, updated to fix faulty
postscript in Fig.
Loss of redundant gene expression after polyploidization in plants
Based on chromosomal location data of genes encoding 28 biochemical systems in allohexaploid wheat,Triticum aestivum L. (genomes AABBDD), it is concluded that the proportions of systems controlled by triplicate, duplicate, and single loci are 57%, 25%, and 18% respectively
Pulse-shape control of two-color interference in high-order-harmonic generation
We report on calculations of harmonic generation by neon in a mixed (800-nm +
time-delayed 400-nm) laser pulse scheme. In contrast with previous studies we
employ a short (few-cycle) 400-nm pulse, finding that this affords control of
the interference between electron trajectories contributing to the cutoff
harmonics. The inclusion of the 400-nm pulse enhances the yield and cutoff
energy, both of which exhibit a strong dependence on the time delay between the
two pulses. Using a combination of time-dependent R-matrix theory and a
classical trajectory model, we assess the mechanisms leading to these effects
SWIRP (Submm-Wave and Long Wave InfraRed Polarimeter); Development and Characterization of a Sub-Mm Polarimeter for Ice Cloud Investigations
A major source of uncertainty in climate models is the presence, shape and distribution of ice particles in the uppermost layers of the clouds. The effects of this component are poorly constrained, turning ice particles into an almost-free variable in many climate models.NASA-GSFC is developing a new instrument aimed at measuring the size and shape of ice particles. The instrument consists of two sub-mm polarimeters (at 220 and 670 GHz) coupled with a long-wave infrared polarimeter at 10 micron. Each polarimeter has identical V-pol and H-pol channels; the axes of polarization are defined geometrically by the orientation of the waveguide elements, and the purity has been measured in the lab. The instrument is configured as a conical scanner, suitable for deployment as a payload on a small satellite or on a high-altitude sub-orbital platform. From a 400 km orbit, the instrument has a 3dB spatial resolution of 20 (10) km at 220 (670) GHz and a swath of 600 km over 180 degrees of view.The BAPTA (Bearing And Power Transfer Assembly) carries heritage from the SSMIS design, now in its 22nd year of on-orbit operation, but with a much reduced SWaP (Size Weight and Power) footprint, suitable for a small satellite.The main components of the instrument have been fabricated and are undergoing final testing prior to their integration as a single unit. The sub-mm channels have dedicated secondary reflectors which illuminate a shared primary reflector. The receiving units are placed behind the focal point of the optical arrangement, so that all beams equally illuminate the primary reflector and are almost co-located on the ground (within a single 220 GHz footprint). Primary and secondary beam patterns have been measured and verified to match the as-designed expectations. A Zytex (TM) window is deployed to protect the secondary reflectors and the feed horns from debris and other contaminants, and to reduce the heat load from the active (hot) IR calibration unit. The insertion loss of Zytex has been measured and is accounted in the calibration equation of the sub-mm channels.The radiometric performance of the sub-mm receivers has been characterized in the lab and under operational conditions of temperature and pressure.This paper discusses the design constraints on the sub-mm components, details of the scientific goals and their flowdown, and describes the characterization of the polarimeters. Options to optimize the layout and distribution of the masses within the assembly, with the goal of making the instrument even more compact and fully-compatible with cubesat-class satellites will be presented
- …