273 research outputs found

    Management of Knee Cartilage Defects with the Autologous Matrix-Induced Chondrogenesis (AMIC) Technique

    Get PDF
    The arthroscopic findings of knee articular cartilage lesions are reported to be as high as 60%, although only a fragment of these are considered to be symptomatic. Such lesions are believed to accelerate the onset of arthritis. Long-term results of the microfracture technique for chondral and osteochondral defects of the knee cartilage are not satisfactory. The autologous matrix induced chondrogenesis (AMIC) technique offers a promising alternative as an effective cartilage repair procedure in the knee resulting in stable clinical results and with a wide range of indications. An extensive literature review has been performed aiming at providing the rationale behind AMIC, to report clinical results of AMIC and to compare AMIC with other chondrogenesis techniques. Finally, we comment on the appropriate surgical technique and its indications, since the number of one-step arthroscopic procedure proposals is steadily increasing

    Single-Row Versus Double-Row Repair in Rotator Cuff Tears

    Get PDF
    Rotator cuff (RC) tear is a common cause of shoulder pain and disability among adults. Surgical management of RC tears is recommended after conservative treatment failure. Due to the development of arthroscopic repair techniques, the use of the arthroscopic rotator cuff repair has become the gold standard. Single-row (SR) and double-row (DR) suture anchor repairs are the two most popular and commonly used arthroscopic techniques. However, the optimal arthroscopic surgical technique remains controversial in terms of clinical and biomechanical outcomes, healing, and re-tear rates. This chapter will focus on differences between these two techniques regarding biomechanics, clinical results, healing rate, and cost effectiveness

    Reconstruction nailing for ipsilateral femoral neck and shaft fractures

    Get PDF
    The surgical management of ipsilateral fractures of the femoral neck and shaft presents a difficult and challenging problem for the orthopaedic surgeon. The purpose of the present study was to report the mid-term results and complications in a series of patients who sustained ipsilateral femoral neck and shaft fractures and treated in our trauma department with a single reconstruction nail for both fractures. Eleven patients were included in the study with an average age of 46.4 years. The mean follow-up was 47 months (range, 15–75 months). There were no cases of a missed diagnosis at initial presentation. The mean time to union was 4.5 months for the neck fracture and 8.2 months for the shaft. There were no cases of avascular necrosis of the femoral head or non-union of the neck fracture. The mean Harris Hip Score was (85 ± 4.3). Complications included two cases of shaft fracture non-union and one case of peroneal nerve palsy. Heterotopic ossification at the tip of the greater trochanter was evident in two cases without causing any functional deficit. The current study suggests that reconstruction nailing produces satisfactory clinical and functional results in the mid-term. The complications involved only the femoral shaft fracture and were successfully treated with a single operative procedure

    Evaluation of the Chondromalacia Patella Using a Microscopy Coil: Comparison of the Two-Dimensional Fast Spin Echo Techniques and the Three-Dimensional Fast Field Echo Techniques

    Get PDF
    Objective: We wanted to compare the two-dimensional (2D) fast spin echo (FSE) techniques and the three-dimensional (3D) fast fi eld echo techniques for the evaluation of the chondromalacia patella using a microscopy coil.Materials and Methods: Twenty five patients who underwent total knee arthroplasty were included in this study. Preoperative MRI evaluation of the patella was performed using a microscopy coil (47 mm). The proton density-weighted fast spin echo images (PD), the fat-suppressed PD images (FS-PD), the intermediate weighted-fat suppressed fast spin echo images (iw-FS-FSE), the 3D balanced-fast fi eld echo images (B-FFE), the 3D water selective cartilage scan (WATS-c) and the 3D water selective fl uid scan (WATS-f) were obtained on a 1.5T MRI scanner. The patellar cartilage was evaluated in nine areas: the superior, middle and the inferior portions that were subdivided into the medial, central and lateral facets in a total of 215 areas. Employing the Noyes grading system, the MRI grade 0-I, II and III lesions were compared using the gross and microscopic fi ndings. The sensitivity, specifi city and accuracy were evaluated for each sequence. The signifi cance of the differences for the individual sequences was calculated using the McNemar test.Results: The gross and microscopic findings demonstrated 167 grade 0-I lesions, 40 grade II lesions and eight grade III lesions. Iw-FS-FSE had the highest accuracy (sensitivity/specificity/accuracy = 88%/98%/96%), followed by FSPD (78%/98%/93%, respectively), PD (76%/98%/93%, respectively), B-FFE (71%/100%/93%, respectively), WATS-c (67%/100%/92%, respectively) and WATS-f (58%/99%/89%, respectively). There were statistically signifi cant differences for the iw-FS-FSE and WATS-f and for the PD-FS and WATS-f (p < 0.01).Conclusion: The iw-FS-FSE images obtained with a microscopy coil show best diagnostic performance among the 2D and 3D GRE images for evaluating the chondromalacia patella

    MRI follow-up of conservatively treated meniscal knee lesions in general practice

    Get PDF
    Objective: To evaluate meniscal status change on follow-up MRI after 1 year, prognostic factors and association with clinical outcome in patients with conservatively treated knee injury. Methods: We analysed 403 meniscal horns in 101 conservatively treated patients (59 male; mean age 40 years) in general practice who underwent initial knee MRI within 5 weeks of trauma. We performed ordinal logistic regression analysis to analyse prognostic factors for meniscal change on follow-up MRI after 1 year, and we assessed the association with clinical outcome. Results: On follow-up MRI 49 meniscal horns had deteriorated and 18 had improved. Age (odds ratio [OR] 1.3/decade), body weight (OR 1.2/10 kg), total anterior cruciate ligament (ACL) rupture on initial MRI (OR 2.4), location in the posterior horn of the medial meniscus (OR 3.0) and an initial meniscal lesion (OR 0.3) were statistically significant predictors of meniscal MRI appearance change after 1 year, which was not associated with clinical outcome. Conclusion: In conservatively treated patients, meniscal deterioration on follow-up MRI 1 year after trauma is predicted by higher age and body weight, initial total ACL rupture, and location in the medial posterior horn. Change in MRI appearance is not associated with clinical outcome
    corecore