263 research outputs found

    Towards simultaneous electrical and optical investigation of BLMS using a novel microfluidic device

    Get PDF
    We firstly describe the influence of the phospholipid (PL) composition of bilayer lipid membrane on their electrical properties: (i) the more unsaturations in the tail, the earlier the BLM breakdown and (ii) the bulkier the head group, the less stable the membrane. Secondly, we design and fabricate novel devices that couple such electri-cal characterization to optical investigation and that enable the preparation of asym-metrical membranes: a ā€œmacroā€ device including a drilled PMMA plate as well as microfluidic device consisting of a glass-teflon foil-glass sandwich

    Microstamped petri dishes for scanning electrochemical microscopy analysis of arrays of microtissues

    Get PDF
    While scanning electrochemical microscopy (SECM) is a powerful technique for non-invasive analysis of cells, SECM-based assays remain scarce and have been mainly limited so far to single cells, which is mostly due to the absence of suitable platform for experimentation on 3D cellular aggregates or microtissues. Here, we report stamping of a Petri dish with a microwell array for large-scale production of microtissues followed by their in situ analysis using SECM. The platform is realized by hot embossing arrays of microwells (200 mum depth; 400 mum diameter) in commercially available Petri dishes, using a PDMS stamp. Microtissues form spontaneously in the microwells, which is demonstrated here using various cell lines (e.g., HeLa, C2C12, HepG2 and MCF-7). Next, the respiratory activity of live HeLa microtissues is assessed by monitoring the oxygen reduction current in constant height mode and at various distances above the platform surface. Typically, at a 40 mum distance from the microtissue, a 30% decrease in the oxygen reduction current is measured, while above 250 mum, no influence of the presence of the microtissues is detected. After exposure to a model drug (50% ethanol), no such changes in oxygen concentration are found at any height in solution, which reflects that microtissues are not viable anymore. This is furthermore confirmed using conventional live/dead fluorescent stains. This live/dead assay demonstrates the capability of the proposed approach combining SECM and microtissue arrays formed in a stamped Petri dish for conducting cellular assays in a non-invasive way on 3D cellular models

    Integrated microfluidic biosensing platform for simultaneous confocal microscopy and electrophysiological measurements on bilayer lipid membranes and ion channels

    Get PDF
    Combining high-resolution imaging and electrophysiological recordings is key for various types of experimentation on lipid bilayers and ion channels. Here, we propose an integrated biosensing platform consisting of a microfluidic cartridge and a dedicated chip-holder to conduct such dual measurements on suspended lipid bilayers, in a user-friendly manner. To illustrate the potential of the integrated platform, we characterize lipid bilayers in terms of thickness and fluidity while simultaneously monitoring single ion channel currents. For that purpose, POPC lipid bilayers are supplemented with a fluorescently-tagged phospholipid (NBD-PE, 1% mol) for Fluorescence Recovery After Photobleaching (FRAP) measurements and a model ion channel (gramicidin, 1 nM). These combined measurements reveal that NBD-PE has no effect on the lipid bilayer thickness while gramicidin induces thinning of the membrane. Furthermore, the presence of gramicidin does not alter the lipid bilayer fluidity. Surprisingly, in lipid bilayers supplemented with both probes, a reduction in gramicidin open probability and lifetime is observed compared to lipid bilayers with gramicidin only, suggesting an influence of NBD-PE on the gramicidin ion function. Altogether, our proposed microfluidic biosensing platform in combination with the herein presented multi-parametric measurement scheme paves the way to explore the interdependent relationship between lipid bilayer properties and ion channel function

    Modular ATR FT-IR microreactor chip for optimizing reaction conditions

    Get PDF
    A silicon chip for attenuated total reflection (ATR) Fourier transform infrared (FT-IR) spectroscopy in combination with a modular PDMS herringbone mixer and a microreactor has been successfully fabricated and tested. The modular design allows the chip to be used for a variety of reactions. A model synthesis of 1-butyl-2,5-dimethyl-1H-pyrrole from hexane-2,5-dione with 1-butylamine has been performed on chip. When plotting the natural logarithm of the peak area corresponding to the ketone stretch vibration at 1710cm-1, against the residence time, a linear curve can be fitted, suggesting this step to be a first order reaction

    A Large Outbreak of Legionnairesā€™ Disease at a Flower Show, the Netherlands, 1999

    Get PDF
    In 1999, an outbreak of Legionnairesā€™ disease affected many visitors to a flower show in the Netherlands. To identify the source of the outbreak, we performed an environmental investigation, as well as a case-control study among visitors and a serologic cohort study among exhibitors to measure exposure to possible sources. Of 77,061 visitors, 188 became ill (133 confirmed and 55 probable cases), for an attack rate of 0.23% for visitors and 0.61% for exhibitors. Two whirlpool spas in halls 3 and 4 of the exhibition and a sprinkler in hall 8 were culture positive for Legionella pneumophila. One of three genotypes found in both whirlpool spas was identical to the isolates from 28 of 29 culture-positive patients. Persons who paused at the whirlpool spa in hall 3 were at increased risk for becoming ill. This study illustrates that whirlpool spas may be an important health hazard if disinfection fails

    Does Repeated Measurement of a 6-Min Walk Test Contribute to Risk Prediction in Children with Dilated Cardiomyopathy?

    Get PDF
    A single 6-min walk test (6MWT) can be used to identify children with dilated cardiomyopathy (DCM) with a high risk of death or heart transplantation. To determine if repeated 6MWT has added value in addition to a single 6MWT in predicting death or heart transplantation in children with DCM. Prospective multicenter cohort study including ambulatory DCM patients >= 6 years. A 6MWT was performed 1 to 4 times per year. The distance walked was expressed as percentage of predicted (6MWD%). We compared the temporal evolution of 6MWD% in patients with and without the study endpoint (SE: all-cause death or heart transplantation), using a linear mixed effects model. In 57 patients, we obtained a median of 4 (IQR 2-6) 6MWTs per patient during a median of 3.0 years of observation (IQR 1.5-5.1). Fourteen patients reached a SE (3 deaths, 11 heart transplantations). At any time during follow-up, the average estimate of 6MWD% was significantly lower in patients with a SE compared to patients without a SE. In both patients groups, 6MWD% remained constant over time. An absolute 1% lower 6MWD% was associated with an 11% higher risk (hazard) of the SE (HR 0.90, 95% CI 0.86-0.95 p <0.001). Children with DCM who died or underwent heart transplantation had systematically reduced 6MWD%. The performance of all patients was stable over time, so repeated measurement of 6MWT within this time frame had little added value over a single test

    Predicting outcome in children with dilated cardiomyopathy:the use of repeated measurements of risk factors for outcome

    Get PDF
    Aims We aimed to determine whether in children with dilated cardiomyopathy repeated measurement of known risk factors for death or heart transplantation (HTx) during disease progression can identify children at the highest risk for adverse outcome. Methods and results Of 137 children we included in a prospective cohort, 36 (26%) reached the study endpoint (SE: all-cause death or HTx), 15 (11%) died at a median of 0.09 years [inter-quartile range (IQR) 0.03-0.7] after diagnosis, and 21 (15%) underwent HTx at a median of 2.9 years [IQR 0.8-6.1] after diagnosis. Median follow-up was 2.1 years [IQR 0.8-4.3]. Twenty-three children recovered at a median of 0.6 years [IQR 0.5-1.4] after diagnosis, and 78 children had ongoing disease at the end of the study. Children who reached the SE could be distinguished from those who did not, based on the temporal evolution of four risk factors: stunting of length growth (-0.42 vs. -0.02 length Z-score per year, P 6 years at presentation (all P < 0.001) were predictive of adverse outcome. In multivariate analysis, NT-proBNP appeared the only independent predictor for adverse outcome, a two-fold higher NT-proBNP was associated with a 2.8 times higher risk of the SE (hazard ratio 2.78, 95% confidence interval 1.81-3.94, P < 0.001). Conclusions The evolution over time of NT-proBNP, LVIDd, length growth, and NYU PHFI identified a subgroup of children with dilated cardiomyopathy at high risk for adverse outcome. In this sample, with a limited number of endpoints, NT-proBNP was the strongest independent predictor for adverse outcome
    • ā€¦
    corecore