8 research outputs found

    Static and dynamic compression load tests of conically connected, screw fixed dental abutment: Implant assemblies

    Get PDF
    The basis of the long-term success of dental implants is the mechanical stability of the implant and the superstructure anchored in it. In order to investigate the mechanical behaviour of the conical connection in implant-abutment units, static and dynamic load tests were performed with different conical angles and various Grade 4-5 titanium implant materials. The assembled units were mounted in self-developed loading machine and in an Instron ElectroPuls E3000 fatigue machine. For static loading, the samples were loaded with a force from 0 N to 500 N in steps of 100 N. For dynamic loading, the samples were loaded for 30,000 cycles with a force of 250 ± 150 N. In case of static testing, the compression caused by the load was measured in both horizontal and vertical directions, while in the case of dynamic fatigue, only horizontal deformation was defined. In both cases, the drive-out (reverse) torque values of the fixing screws were determined after loading. No significant differences were found between the tested materials in the reverse torque after the static load, however, significant differences were shown with regards to the alterations in cone angle (p < 0.001). After dynamic loading, significant differences (p < 0.001) were also observed between the reverse torques of the fixing screw in different angles. The static and dynamic test results showed the same tendency: under the same load conditions, the conical angle value of the implant-abutment connection revealed significant differences in the loosening of the fixing screw. In summary, it is recommended to use higher conical angle connection to avoid larger deformations in lengths and diameters of the implant at the connection and essential torque reduction of the fixing screw. Our results may contribute to the understanding of the long-term success of dental implants

    Regeneration of Intrabony Defects Using a Novel Magnesium Membrane

    Get PDF
    Background and Objectives: Due to their specific morphology, the regeneration of intrabony defects (IBDs) represents one of the greatest challenges for clinicians. Based on the specific properties of a magnesium membrane, a new approach for the surgical treatment of IBD was developed. The surgical procedure was described using a series of three cases. Materials and Methods: The patients were healthy individuals suffering from a severe form of periodontitis associated with IBD. Based on radiographic examination, the patients had interproximal bone loss of at least 4 mm. Due to its good mechanical properties, it was easy to cut and shape the magnesium membrane into three different shapes to treat the specific morphology of each IBD. In accordance with the principles of guided bone regeneration, a bovine xenograft was used to fill the IBD in all cases. Results: After a healing period of 4 to 6 months, successful bone regeneration was confirmed using radiological analysis. The periodontal probing depth (PPD) after healing showed a reduction of 1.66 +/- 0.29 mm. Conclusions: Overall, the use of the different shapes of the magnesium membrane in the treatment of IBD resulted in a satisfactory functional and esthetic outcome

    Static and dynamic compression load tests of conically connected, screw fixed dental abutment

    Get PDF
    The basis of the long-term success of dental implants is the mechanical stability of the implant and the superstructure anchored in it. In order to investigate the mechanical behaviour of the conical connection in implant-abutment units, static and dynamic load tests were performed with different conical angles and various Grade 4-5 titanium implant materials. The assembled units were mounted in self-developed loading machine and in an Instron ElectroPuls E3000 fatigue machine. For static loading, the samples were loaded with a force from 0 N to 500 N in steps of 100 N. For dynamic loading, the samples were loaded for 30,000 cycles with a force of 250 ± 150 N. In case of static testing, the compression caused by the load was measured in both horizontal and vertical directions, while in the case of dynamic fatigue, only horizontal deformation was defined. In both cases, the drive-out (reverse) torque values of the fixing screws were determined after loading. No significant differences were found between the tested materials in the reverse torque after the static load, however, significant differences were shown with regards to the alterations in cone angle (p < 0.001). After dynamic loading, significant differences (p < 0.001) were also observed between the reverse torques of the fixing screw in different angles. The static and dynamic test results showed the same tendency: under the same load conditions, the conical angle value of the implant-abutment connection revealed significant differences in the loosening of the fixing screw. In summary, it is recommended to use higher conical angle connection to avoid larger deformations in lengths and diameters of the implant at the connection and essential torque reduction of the fixing screw. Our results may contribute to the understanding of the long-term success of dental implants

    Prasugrel Versus Clopidogrel: A Comparative Examination of Local Bleeding After Dental Extraction in Patients Receiving Dual Antiplatelet Therapy

    Get PDF
    PURPOSE: To study the effects of various parameters on local hemostasis after dental extraction in patients receiving different combinations of medications who had previously confirmed effective dual inhibition of platelet aggregation. MATERIALS AND METHODS: A total of 129 patients were enrolled. They underwent acute or planned percutaneous coronary intervention and their stomatological examination disclosed teeth that could have acted as foci and thus had to be removed. All patients took acetylsalicylic acid 100 mg and clopidogrel or Prasugrel. Lidocaine with or without epinephrine was used for local anesthesia, and a gauze swab or suture was applied to help hemostasis. RESULTS: Bleeding time was significantly longer by an average of 10 minutes (+21%) in patients taking Prasugrel (P < .05) compared with those taking clopidogrel. Use of a suture resulted in a significantly shorter bleeding time after anesthesia with or without epinephrine (P < .05). A considerably longer bleeding time was observed when anesthesia with no epinephrine was combined with gauze. In smokers, the bleeding time was shorter by 15% on average. CONCLUSION: This study is the first to analyze differences in bleeding times between clopidogrel and Prasugrel treatments during dental extraction. In general, Prasugrel is associated with a considerably longer bleeding time; nevertheless, dental extraction can be performed safely with either combination

    Different Conical Angle Connection of Implant and Abutment Behavior: A Static and Dynamic Load Test and Finite Element Analysis Study

    Get PDF
    Dental implants are artificial dental roots anchoring prosthetic restorations to replace natural teeth. Dental implant systems may have different tapered conical connections. Our research focused on the mechanical examination of implant–superstructure connections. Thirty-five samples with 5 different cone angles (24°, 35°, 55°, 75°, and 90°) were tested for static and dynamic loads, carried out by a mechanical fatigue testing machine. Fixing screws were fixed with a torque of 35 Ncm before measurements. For static loading, samples were loaded with a force of 500 N in 20 s. For dynamic loading, the samples were loaded for 15,000 cycles with a force of 250 ± 150 N. In both cases, the compression resulting from load and reverse torque was examined. At the highest compression load of the static tests, a significant difference (p = 0.021) was found for each cone angle group. Following dynamic loading, significant differences (p < 0.001) for the reverse torques of the fixing screw were also shown. Static and dynamic results showed a similar trend: under the same loading conditions, changing the cone angle—which determines the relationship between the implant and the abutment—had led to significant differences in the loosening of the fixing screw. In conclusion, the greater the angle of the implant–superstructure connection, the smaller the screw loosening due to loading, which may have considerable effects on the long-term, safe operation of the dental prosthesis