9,497 research outputs found

    Optimization of Single-Sided Charge-Sharing Strip Detectors

    Get PDF
    Simulation of the charge sharing properties of single-sided CZT strip detectors with small anode pads are presented. The effect of initial event size, carrier repulsion, diffusion, drift, trapping and detrapping are considered. These simulations indicate that such a detector with a 150 µm pitch will provide good charge sharing between neighboring pads. This is supported by a comparison of simulations and measurements for a similar detector with a coarser pitch of 225 µm that could not provide sufficient sharing. The performance of such a detector used as a gamma-ray imager is discussed

    Parallel Temperatures in Supersonic Beams: Ultra Cooling of Light Atoms seeded in a Heavier Carrier Gas

    Full text link
    We have found recently that, in a supersonic expansion of a mixture of two monoatomic gases, the parallel temperatures of the two gases can be very different. This effect is large if the seeded gas is highly diluted and if its atomic mass is considerably smaller than the one of the carrier gas. In the present paper, we present a complete derivation of our theoretical analysis of this effect. Our calculation is a natural extension of the existing theory of supersonic cooling to the case of a gas mixture, in the high dilution limit. Finally, we describe a set of temperature measurements made on a beam of lithium seeded in argon. Our experimental results are in very good agreement with the results of our calculation.Comment: 24 novembre 200

    Further studies of single-sided charge-sharing CZT strip detectors

    Get PDF
    We report progress in the study of a thick CZT strip detector module designed to perform gamma-ray spectroscopy and 3-D imaging. We report preliminary performance measurements of 7.5 mm thick single-sided charge-sharing strip detector prototype devices. This design features both row and column contacts on the anode surface. This electron-only approach addresses problems associated with poor hole transport in CZT that limit the thickness and energy range of double-sided strip detectors. This work includes laboratory and simulation studies aimed at developing compact, efficient, detector modules for 0.05 to 1 MeV gamma measurements while minimizing the number and complexity of the electronic readout channels. This is particularly important in space-based coded aperture and Compton telescope instruments that require large area, large volume detector arrays. Such arrays will be required for the NASA Black Hole Finder Probe (BHFP)and Advanced Compton Telescope (ACT). This new design requires an anode pattern with contacts whose dimensions and spacing are roughly the size of the ionization charge cloud. The first prototype devices have 125 ÎĽm anode contacts on 225 ÎĽm pitch. Our results demonstrate the principle of operation but suggest that even finer anode contact feature sizes will be necessary to achieve the desired performance

    Continued Studies of Single-Sided Charge-Sharing CZT Strip Detectors

    Get PDF
    In this paper, we report progress in the study of thick single-sided charge-sharing cadmium zinc telluride (CZT) strip detector modules designed to perform gammaray spectroscopy and 3-D imaging. We report on continuing laboratory and simulation measurements of prototype detectors with 11×11 unit cells (15×15×7.5mm3 ). We report preliminary measurements of the 3-D spatial resolution. Our studies are aimed at developing compact, efficient, detector modules for 0.05 to 1 MeV gamma measurements while minimizing the number and complexity of the electronic readout channels. This is particularly important in space-based coded aperture and Compton telescope instruments that require large area, large volume detector arrays. Such arrays will be required for the NASA’s Black Hole Finder Probe (BHFP) and Advanced Compton Telescope (ACT). This design requires an anode pattern with contacts whose dimensions and spacing are roughly the size of the ionization charge cloud. The first prototype devices have 125µm anode contacts on 225µm pitch. Our studies conclude that finer pitch contacts will be required to improve imaging efficiency

    Development of CZT strip detector modules for 0.05- to 1-MeV gamma-ray imaging and spectroscopy

    Get PDF
    We report progress in our study of cadmium zinc telluride (CZT) strip detectors featuring orthogonal coplanar anode contacts. We specifically report on the performance, characterization and stability of 5 and 10 mm thick prototype CZT detectors fabricated using material from several manufacturers. Our ongoing work includes laboratory and simulation studies aimed at optimizing and developing compact, efficient, high performance detector modules for 0.05 to 1 MeV gamma radiation measurements with space-based instrumentation. The coplanar anode strip configuration retains many of the performance advantages of pixel detectors yet requires far fewer electronic channels to perform both 3-d imaging and spectroscopy. Minimizing the channel count is important for large balloon or space instruments including coded aperture telescopes (such as MARGIE or EXIST) and Compton imaging telescopes (such as TIGRE or ACT). We also present plans for developing compact, space qualified imaging modules designed for integration into closely packed large area detector arrays. We discuss issues associated with detector module and array electronics design and development

    Readout and performance of thick CZT strip detectors with orthogonal coplanar anodes

    Get PDF
    We report progress in the study of CZT strip detectors featuring orthogonal coplanar anode contacts. The work includes laboratory and simulation studies aimed at optimizing and developing compact, efficient, high performance detector modules for 0.05 to 1 MeV gamma radiation measurements. The novel coplanar anode strip configuration retains many of the performance advantages of pixel detectors yet requires far fewer electronic channels to perform both 3-d imaging and spectroscopy. We report on studies aimed at determining an optimum configuration of the analog signal processing electronics to employ with these detectors. We report measurements of energy and spatial resolution in three dimensions for prototype 5 and 10 mm thick CZT detectors using a set of shaping and summing amplifiers

    Single-sided CZT strip detectors

    Get PDF
    We report progress in the study of thick CZT strip detectors for 3-d imaging and spectroscopy and discuss two approaches to device design. We present the spectroscopic, imaging, detection efficiency and response uniformity performance of prototype devices. Unlike double-sided strip detectors, these devices feature both row and column contacts implemented on the anode surface. This electron-only approach circumvents problems associated with poor hole transport in CZT that normally limit the thickness and energy range of double-sided strip detectors. These devices can achieve similar performance to pixel detectors. The work includes laboratory and simulation studies aimed at developing compact, efficient, detector modules for 0.05 to 1 MeV gamma radiation measurements. The low channel count strip detector approach can significantly reduce the complexity and power requirements of the readout electronics. This is particularly important in space-based coded aperture or Compton telescope instruments requiring large area, large volume detector arrays. Such arrays will be required for NASA\u27s Black Hole Finder Probe (BHFP) and Advanced Compton Telescope (ACT)

    Schur Polynomials and the Yang-Baxter equation

    Get PDF
    We show that within the six-vertex model there is a parametrized Yang-Baxter equation with nonabelian parameter group GL(2)xGL(1) at the center of the disordered regime. As an application we rederive deformations of the Weyl character formule of Tokuyama and of Hamel and King.Comment: Revised introduction; slightly changed reference

    Hubungan Status Gizi Dengan Kadar Kolesterol Total Pada Masyarakat Di Kelurahan Bahu Kecamatan Malalayang Manado

    Full text link
    : Total cholesterol level reading as an indicator can be use to assess the risk of heart disease. Nutritional status is a form of imbalance between intake the body needs and it can be lead to malnutrition and over nutrition. To determine the nutritional status can be used by calculating the body mass index as an indicator to assessing the obesity. Hypercholesterolemia level with obesity related to pathologic condition likes atherosclerosis and heart disease. This research is aim to understand the relationship between nutritional status and total cholesterol level in the community at Bahu village Malalayang Subdistrict Manado. The study method of this analytic is cross-sectional disign study. The sampling technique used is probability sampling by simple random sampling which is conducted of 63 persons. The statistic result show by used chi-square test is p = 0,557 with confident interval 95%. The p value mean it\u27s bigger than α (0,05).The conclution means there is no significant relationship between nutritional status and total cholesterol level in the community at Bahu village Malalayang Subdistrict Manado
    • …
    corecore