721 research outputs found
The catalytic removal of ammonia and nitrogen oxides from spacecabin atmospheres
Investigations were made on methods for the removal of ammonia and to a lesser extent nitrogen oxides in low concentrations from air. The catalytic oxidation of ammonia was studied over a temperature range of 250 F to 600 F and a concentration range 20 ppm to 500 ppm. Of the catalysts studied, 0.5 percent ruthenium supported on alumina was found to be superior. This material is active at temperatures as low as 250 F and was found to produce much less nitrous oxide than the other two active catalysts, platinum on alumina and Hopcalite. A quantitative design model was developed which will permit the performance of an oxidizer to be calculated. The ruthenium was found to be relatively insensitive to low concentrations of water and to oxygen concentration between 21 percent and 100 percent. Hydrogen sulfide was found to be a poison when injected in relatively large quantities. The adsorption of ammonia by copper sulfate treated silica gel was investigated at temperatures of 72 F and 100 F. A quantitative model was developed for predicting adsorption bed behavior
Computer-assisted polyp matching between optical colonoscopy and CT colonography: a phantom study
Potentially precancerous polyps detected with CT colonography (CTC) need to
be removed subsequently, using an optical colonoscope (OC). Due to large
colonic deformations induced by the colonoscope, even very experienced
colonoscopists find it difficult to pinpoint the exact location of the
colonoscope tip in relation to polyps reported on CTC. This can cause unduly
prolonged OC examinations that are stressful for the patient, colonoscopist and
supporting staff.
We developed a method, based on monocular 3D reconstruction from OC images,
that automatically matches polyps observed in OC with polyps reported on prior
CTC. A matching cost is computed, using rigid point-based registration between
surface point clouds extracted from both modalities. A 3D printed and painted
phantom of a 25 cm long transverse colon segment was used to validate the
method on two medium sized polyps. Results indicate that the matching cost is
smaller at the correct corresponding polyp between OC and CTC: the value is 3.9
times higher at the incorrect polyp, comparing the correct match between polyps
to the incorrect match. Furthermore, we evaluate the matching of the
reconstructed polyp from OC with other colonic endoluminal surface structures
such as haustral folds and show that there is a minimum at the correct polyp
from CTC.
Automated matching between polyps observed at OC and prior CTC would
facilitate the biopsy or removal of true-positive pathology or exclusion of
false-positive CTC findings, and would reduce colonoscopy false-negative
(missed) polyps. Ultimately, such a method might reduce healthcare costs,
patient inconvenience and discomfort.Comment: This paper was presented at the SPIE Medical Imaging 2014 conferenc
Recommended from our members
Inverse Consistency Error in the Registration of Prone and Supine Images in CT Colonography
Robust registration between prone and supine data acquisitions for CT colonography is pivotal for medical interpretation but a challenging problem. One measure when evaluating non-rigid registration algorithms over the whole of the deformation field is the inverse consistency error, which suggests improved registration quality when the inverse deformation is consistent with the forward deformation. We show that using computed landmark displacements to initialise an intensity based registration reduces the inverse consistency error when using a state-of-the-art non-rigid b-spline registration method. This method aligns prone and supine 2D images derived from CT colonography acquisitions in a cylindrical domain. Furthermore, we demonstrate that using the same initialisation also improves registration accuracy for a set of manually identified reference points in cases exhibiting local luminal collapse
Religious faith and psychosocial adaptation among stroke patients in Kuwait: A mixed method study
This is the author's accepted manuscript. The final published article is available from the link below. Copyright @ 2012 Springer Science+Business Media.Religious faith is central to life for Muslim patients in Kuwait, so it may influence adaptation and rehabilitation. This study explored quantitative associations among religious faith, self-efficacy, and life satisfaction in 40 female stroke patients and explored the influence of religion within stroke rehabilitation through qualitative interviews with 12 health professionals. The quantitative measure of religious faith did not relate to life satisfaction or self-efficacy in stroke patients. However, the health professionals described religious coping as influencing adaptation post-stroke. Fatalistic beliefs were thought to have mixed influences on rehabilitation. Measuring religious faith among Muslims through a standardized scale is debated. The qualitative accounts suggest that religious beliefs need to be acknowledged in stroke rehabilitation in Kuwait
The second ESGAR consensus statement on CT colonography
Objective: To update quality standards for CT colonography based on consensus among opinion leaders within the European Society of Gastrointestinal and Abdominal Radiology (ESGAR). Material and methods: A multinational European panel of nine members of the ESGAR CT colonography Working Group (representing six EU countries) used a modified Delphi process to rate their level of agreement on a variety of statements pertaining to the acquisition, interpretation and implementation of CT colonography. Four Delphi rounds were conducted, each at 2 months interval. Results: The panel elaborated 86 statements. In the final round the panelists achieved complete consensus in 71 of 86 statements (82 %). Categories including the highest proportion of statements with excellent Cronbach's internal reliability were colon distension, scan parameters, use of intravenous contrast agents, general guidelines on patient preparation, role of CAD and lesion measurement. Lower internal reliability was achieved for the use of a rectal tube, spasmolytics, decubitus positioning and number of CT data acquisitions, faecal tagging, 2D vs. 3D reading, and reporting. Conclusion: The recommendations of the consensus should be useful for both the radiologist who is starting a CTC service and for those who have already implemented the technique but whose practice may need updating. Key Points: • Computed tomographic colonography is the optimal radiological method of assessing the colon • This article reviews ESGAR quality standards for CT colonography • This article is aimed to provide CT-colonography guidelines for practising radiologists • The recommendations should help radiologists who are starting/updating their CTC services © 2012 The Author(s)
Randomized Comparison of a CrossBoss First Versus Standard Wire Escalation Strategy for Crossing Coronary Chronic Total Occlusions: The CrossBoss First Trial
OBJECTIVES: The authors performed a multicenter, randomized-controlled, clinical trial comparing upfront use of the CrossBoss catheter versus antegrade wire escalation for antegrade crossing of coronary chronic total occlusions. BACKGROUND: There is equipoise about the optimal initial strategy for crossing coronary chronic total occlusions. METHODS: The primary endpoints were the time required to cross the chronic total occlusion or abort the procedure and the frequency of procedural major adverse cardiovascular events. The secondary endpoints were technical and procedural success, total procedure time, fluoroscopy time required to cross and total fluoroscopy time, total air kerma radiation dose, total contrast volume, and equipment use. RESULTS: Between 2015 and 2017, 246 patients were randomized to the CrossBoss catheter (n = 122) or wire escalation (n = 124) at 11 U.S. centers. The baseline clinical and angiographic characteristics of the study groups were similar. Technical and procedural success were 87.8% and 84.1%, respectively, and were similar in the 2 groups. Crossing time was similar: 56 min (interquartile range: 33 to 93 min) in the CrossBoss group and 66 min (interquartile range: 36 to 105 min) in the wire escalation group (p = 0.323), as was as the incidence of procedural major adverse cardiovascular events (3.28% vs. 4.03%; p = 1.000). There were no significant differences in the secondary study endpoints. CONCLUSIONS: As compared with wire escalation, upfront use of the CrossBoss catheter for antegrade crossing of coronary chronic total occlusions was associated with similar crossing time, similar success and complication rates, and similar equipment use and cost
Are lay people good at recognising the symptoms of schizophrenia?
©2013 Erritty, Wydell. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.This article has been made available through the Brunel Open Access Publishing Fund.Aim: The aim of this study was to explore the general public’s perception of schizophrenia symptoms and the need to seekhelp for symptoms. The recognition (or ‘labelling’) of schizophrenia symptoms, help-seeking behaviours and public
awareness of schizophrenia have been suggested as potentially important factors relating to untreated psychosis.
Method: Participants were asked to rate to what extent they believe vignettes describing classic symptoms (positive and
negative) of schizophrenia indicate mental illness. They were also asked if the individuals depicted in the vignettes required help or treatment and asked to suggest what kind of help or treatment.
Results: Only three positive symptoms (i.e., Hallucinatory behaviour, Unusual thought content and Suspiciousness) of schizophrenia were reasonably well perceived (above 70%) as indicating mental illness more than the other positive or negative symptoms. Even when the participants recognised that the symptoms indicated mental illness, not everyone recommended professional help.
Conclusion: There may be a need to improve public awareness of schizophrenia and psychosis symptoms, particularly regarding an awareness of the importance of early intervention for psychosis
Recommended from our members
CT colonography: external clinical validation of an algorithm for computer-assisted prone and supine registration
Purpose
To perform external validation of a computer-assisted registration algorithm for prone and supine computed tomographic (CT) colonography and to compare the results with those of an existing centerline method.
Materials and Methods
All contributing centers had institutional review board approval; participants provided informed consent. A validation sample of CT colonographic examinations of 51 patients with 68 polyps (6–55 mm) was selected from a publicly available, HIPAA compliant, anonymized archive. No patients were excluded because of poor preparation or inadequate distension. Corresponding prone and supine polyp coordinates were recorded, and endoluminal surfaces were registered automatically by using a computer algorithm. Two observers independently scored three-dimensional endoluminal polyp registration success. Results were compared with those obtained by using the normalized distance along the colonic centerline (NDACC) method. Pairwise Wilcoxon signed rank tests were used to compare gross registration error and McNemar tests were used to compare polyp conspicuity.
Results
Registration was possible in all 51 patients, and 136 paired polyp coordinates were generated (68 polyps) to test the algorithm. Overall mean three-dimensional polyp registration error (mean ± standard deviation, 19.9 mm ± 20.4) was significantly less than that for the NDACC method (mean, 27.4 mm ± 15.1; P = .001). Accuracy was unaffected by colonic segment (P = .76) or luminal collapse (P = .066). During endoluminal review by two observers (272 matching tasks, 68 polyps, prone to supine and supine to prone coordinates), 223 (82%) polyp matches were visible (120° field of view) compared with just 129 (47%) when the NDACC method was used (P < .001). By using multiplanar visualization, 48 (70%) polyps were visible after scrolling ± 15 mm in any multiplanar axis compared with 16 (24%) for NDACC (P < .001).
Conclusion
Computer-assisted registration is more accurate than the NDACC method for mapping the endoluminal surface and matching the location of polyps in corresponding prone and supine CT colonographic acquisitions
- …