44 research outputs found

    A novel application of capnography during controlled human exposure to air pollution

    Get PDF
    BACKGROUND: The objective was to determine the repeatability and stability of capnography interfaced with human exposure facility. METHODS: Capnographic wave signals were obtained from five healthy volunteers exposed to particle-free, filtered air during two consecutive 5 min intervals, 10 min apart, within the open and then the sealed and operational human exposure facility (HEF). Using a customized setup comprised of the Oridion Microcap(® )portable capnograph, DA converter and AD card, the signal was acquired and saved as an ASCII file for subsequent processing. The minute ventilation (VE), respiratory rate (RR) and expiratory tidal volume (V(TE)) were recorded before and after capnographic recording and then averaged. Each capnographic tracing was analyzed for acceptable waves. From each recorded interval, 8 to 19 acceptable waves were selected and measured. The following wave parameters were obtained: total length and length of phase II and III, slope of phase II and III, area under the curve and area under phase III. In addition, we recorded signal measures including the mean, standard deviation, mode, minimum, maximum – which equals end-tidal CO(2 )(EtCO(2)), zero-corrected maximum and true RMS. RESULTS: Statistical analysis using a paired t-test for means showed no statistically significant changes of any wave parameters and wave signal measures, corrected for RR and V(TE), comparing the measures when the HEF was open vs. sealed and operational. The coefficients of variation of the zero-corrected and uncorrected EtCO(2), phase II absolute difference, signal mean, standard deviation and RMS were less than 10% despite a sub-atmospheric barometric pressure, and slightly higher temperature and relative humidity within the HEF when operational. CONCLUSION: We showed that a customized setup for the acquisition and processing of the capnographic wave signal, interfaced with HEF was stable and repeatable. Thus, we expect that analysis of capnographic waves in controlled human air pollution exposure studies is a feasible tool for characterization of cardio-pulmonary effects of such exposures

    The correlation and level of agreement between end-tidal and blood gas pCO2 in children with respiratory distress: a retrospective analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To investigate the correlation and level of agreement between end-tidal carbon dioxide (EtCO<sub>2</sub>) and blood gas pCO<sub>2 </sub>in non-intubated children with moderate to severe respiratory distress.</p> <p>Methods</p> <p>Retrospective study of patients admitted to an intermediate care unit (InCU) at a tertiary care center over a 20-month period with moderate to severe respiratory distress secondary to asthma, bronchiolitis, or pneumonia. Patients with venous pCO<sub>2 </sub>(vpCO<sub>2</sub>) and EtCO<sub>2 </sub>measurements within 10 minutes of each other were eligible for inclusion. Patients with cardiac disease, chronic pulmonary disease, poor tissue perfusion, or metabolic abnormalities were excluded.</p> <p>Results</p> <p>Eighty EtCO<sub>2</sub>-vpCO<sub>2 </sub>paired values were available from 62 patients. The mean ± <smcaps>SD</smcaps> for EtCO<sub>2 </sub>and vpCO<sub>2 </sub>was 35.7 ± 10.1 mmHg and 39.4 ± 10.9 mmHg respectively. EtCO<sub>2 </sub>and vpCO<sub>2 </sub>values were highly correlated (r = 0.90, p < 0.0001). The correlations for asthma, bronchiolitis and pneumonia were 0.74 (p < 0.0001), 0.83 (p = 0.0002) and 0.98 (p < 0.0001) respectively. The mean bias ± <smcaps>SD</smcaps> between EtCO<sub>2 </sub>and vpCO<sub>2 </sub>was -3.68 ± 4.70 mmHg. The 95% level of agreement ranged from -12.88 to +5.53 mmHg. EtCO<sub>2 </sub>was found to be more accurate when vpCO<sub>2 </sub>was 35 mmHg or lower.</p> <p>Conclusion</p> <p>EtCO<sub>2 </sub>is correlated highly with vpCO<sub>2 </sub>in non-intubated pediatric patients with moderate to severe respiratory distress across respiratory illnesses. Although the level of agreement between the two methods precludes the overall replacement of blood gas evaluation, EtCO<sub>2 </sub>monitoring remains a useful, continuous, non-invasive measure in the management of non-intubated children with moderate to severe respiratory distress.</p

    Microbial carbon use efficiency: accounting for population, community, and ecosystem-scale controls over the fate of metabolized organic matter

    Get PDF
    Microbial carbon use efficiency (CUE) is a critical regulator of soil organic matter dynamics and terrestrial carbon fluxes, with strong implications for soil biogeochemistry models. While ecologists increasingly appreciate the importance of CUE, its core concepts remain ambiguous: terminology is inconsistent and confusing, methods capture variable temporal and spatial scales, and the significance of many fundamental drivers remains inconclusive. Here we outline the processes underlying microbial efficiency and propose a conceptual framework that structures the definition of CUE according to increasingly broad temporal and spatial drivers where (1) CUEP reflects population-scale carbon use efficiency of microbes governed by species-specific metabolic and thermodynamic constraints, (2) CUEC defines community-scale microbial efficiency as gross biomass production per unit substrate taken up over short time scales, largely excluding recycling of microbial necromass and exudates, and (3) CUEE reflects the ecosystem-scale efficiency of net microbial biomass production (growth) per unit substrate taken up as iterative breakdown and recycling of microbial products occurs. CUEE integrates all internal and extracellular constraints on CUE and hence embodies an ecosystem perspective that fully captures all drivers of microbial biomass synthesis and decay. These three definitions are distinct yet complementary, capturing the capacity for carbon storage in microbial biomass across different ecological scales. By unifying the existing concepts and terminology underlying microbial efficiency, our framework enhances data interpretation and theoretical advances