212 research outputs found

    Clinical outcomes of stereotactic body radiotherapy for stage I non-small cell lung cancer using different doses depending on tumor size

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The treatment schedules for stereotactic body radiotherapy (SBRT) for lung cancer vary from institution to institution. Several reports have indicated that stage IB patients had worse outcomes than stage IA patients when the same dose was used. We evaluated the clinical outcomes of SBRT for stage I non-small cell lung cancer (NSCLC) treated with different doses depending on tumor diameter.</p> <p>Methods</p> <p>Between February 2004 and November 2008, 124 patients with stage I NSCLC underwent SBRT. Total doses of 44, 48, and 52 Gy were administered for tumors with a longest diameter of less than 1.5 cm, 1.5-3 cm, and larger than 3 cm, respectively. All doses were given in 4 fractions.</p> <p>Results</p> <p>For all 124 patients, overall survival was 71%, cause-specific survival was 87%, progression-free survival was 60%, and local control was 80%, at 3 years. The 3-year overall survival was 79% for 85 stage IA patients treated with 48 Gy and 56% for 37 stage IB patients treated with 52 Gy (<it>p </it>= 0.05). At 3 years, cause-specific survival was 91% for the former group and 79% for the latter (<it>p </it>= 0.18), and progression-free survival was 62% versus 54% (<it>p </it>= 0.30). The 3-year local control rate was 81% versus 74% (<it>p </it>= 0.35). The cumulative incidence of grade 2 or 3 radiation pneumonitis was 11% in stage IA patients and 30% in stage IB patients (<it>p </it>= 0.02).</p> <p>Conclusions</p> <p>There was no difference in local control between stage IA and IB tumors despite the difference in tumor size. The benefit of increasing the SBRT dose for larger tumors should be investigated further.</p

    Optimization of extracranial stereotactic radiation therapy of small lung lesions using accurate dose calculation algorithms

    Get PDF
    BACKGROUND: The aim of this study was to compare and to validate different dose calculation algorithms for the use in radiation therapy of small lung lesions and to optimize the treatment planning using accurate dose calculation algorithms. METHODS: A 9-field conformal treatment plan was generated on an inhomogeneous phantom with lung mimics and a soft tissue equivalent insert, mimicking a lung tumor. The dose distribution was calculated with the Pencil Beam and Collapsed Cone algorithms implemented in Masterplan (Nucletron) and the Monte Carlo system XVMC and validated using Gafchromic EBT films. Differences in dose distribution were evaluated. The plans were then optimized by adding segments to the outer shell of the target in order to increase the dose near the interface to the lung. RESULTS: The Pencil Beam algorithm overestimated the dose by up to 15% compared to the measurements. Collapsed Cone and Monte Carlo predicted the dose more accurately with a maximum difference of -8% and -3% respectively compared to the film. Plan optimization by adding small segments to the peripheral parts of the target, creating a 2-step fluence modulation, allowed to increase target coverage and homogeneity as compared to the uncorrected 9 field plan. CONCLUSION: The use of forward 2-step fluence modulation in radiotherapy of small lung lesions allows the improvement of tumor coverage and dose homogeneity as compared to non-modulated treatment plans and may thus help to increase the local tumor control probability. While the Collapsed Cone algorithm is closer to measurements than the Pencil Beam algorithm, both algorithms are limited at tissue/lung interfaces, leaving Monte-Carlo the most accurate algorithm for dose prediction

    Limits on the production of scalar leptoquarks from Z (0) decays at LEP

    Get PDF
    A search has been made for pairs and for single production of scalar leptoquarks of the first and second generations using a data sample of 392000 Z0 decays from the DELPHI detector at LEP 1. No signal was found and limits on the leptoquark mass, production cross section and branching ratio were set. A mass limit at 95% confidence level of 45.5 GeV/c2 was obtained for leptoquark pair production. The search for the production of a single leptoquark probed the mass region above this limit and its results exclude first and second generation leptoquarks D0 with masses below 65 GeV/c2 and 73 GeV/c2 respectively, at 95% confidence level, assuming that the D0lq Yukawa coupling alpha(lambda) is equal to the electromagnetic one. An upper limit is also given on the coupling alpha(lambda) as a function of the leptoquark mass m(D0)

    First Measurement of the Strange Quark Asymmetry at the Z0Z^{0} Peak

    Get PDF

    Invariant mass dependence of particle correlations in hadronic final states from the decay of the Z0^0

    Get PDF
    corecore