3,439 research outputs found

    Psychological interventions for mental health disorders in children with chronic physical illness: a systematic review.

    Get PDF
    Children with chronic physical illness are significantly more likely to develop common psychiatric symptoms than otherwise healthy children. These children therefore warrant effective integrated healthcare yet it is not established whether the known, effective, psychological treatments for symptoms of common childhood mental health disorders work in children with chronic physical illness

    Rapidly quantifying the relative distention of a human bladder

    Get PDF
    A device and method was developed to rapidly quantify the relative distention of the bladder of a human subject. An ultrasonic transducer is positioned on the human subject near the bladder. A microprocessor controlled pulser excites the transducer by sending an acoustic wave into the human subject. This wave interacts with the bladder walls and is reflected back to the ultrasonic transducer where it is received, amplified, and processed by the receiver. The resulting signal is digitized by an analog to digital converter, controlled by the microprocessor again, and is stored in data memory. The software in the microprocessor determines the relative distention of the bladder as a function of the propagated ultrasonic energy. Based on programmed scientific measurements and the human subject's past history as contained in program memory, the microprocessor sends out a signal to turn on any or all of the available alarms. The alarm system includes and audible alarm, the visible alarm, the tactile alarm, and the remote wireless alarm

    Intestinal absorption of macromolecules during viral enteritis: an experimental study on rotavirus-infected conventional and germ-free mice.

    Get PDF
    Epithelial transport and degradation of horseradish peroxidase (HRP), a macromolecular tracer, was studied in conventional and germ-free suckling mice following an experimental infection with rotavirus. Conventional and germ-free mice developed diarrhea from days 2 to 8 postinfection (pi), with growth failure. In mucosal homogenates, infectious virus detected by immunofluorescence on MA 104 cells was present from day 2 through day 8 pi in germ-free mice, but persisted longer (day 13 pi) in conventional mice. Only mild histological lesions were observed during diarrhea, but obvious macrovacuolation of epithelial cells and increased cellular density occurred during the convalescence period (days 9 to 13 pi). Intact and degraded HRP fluxes from mucosa to serosa were measured in vitro on segments of jejunum mounted in Ussing chambers. Both groups of mice developed increased HRP permeability during the experimental period, but at different times after inoculation: during the diarrheal period (days 2 and 3 pi) conventional mouse epithelium absorbed five times more HRP than noninfected controls and during the convalescence period (days 9 to 13 pi) HRP absorption in germ-free mice rose 10-fold as compared to its level before infection. In both cases, this increase in HRP permeability was entirely due to an increase in intact HRP absorption, probably via a transcellular route, and occurred without any alteration in degraded HRP transport. These results indicate that in mice, rotavirus infection causes a transient rise in gut permeability to undegraded proteins. The intestinal microflora seems to affect the timing, magnitude, and duration of this increased permeability

    Liquid-immersible electrostatic ultrasonic transducer

    Get PDF
    A broadband megahertz range electrostatic acoustic transducer for use in a liquid environment is described. A liquid tight enclosure includes a metallic conducting membrane as part of its outside surface and has a means inside the liquid tight enclosure for applying a tension to the membrane and for mounting an electrode such that the flat end of the electrode is aproximately parallel to the membrane. The invention includes structure and a method for ensuring that the membrane and the flat end of the electrode are exactly parallel and a fixed predetermined distance from each other

    Rapidly quantifying the relative distention of a human bladder

    Get PDF
    A device and method of rapidly quantifying the relative distention of the bladder in a human subject are disclosed. The ultrasonic transducer which is positioned on the subject in proximity to the bladder is excited by a pulser under the command of a microprocessor to launch an acoustic wave into the patient. This wave interacts with the bladder walls and is reflected back to the ultrasonic transducer, when it is received, amplified and processed by the receiver. The resulting signal is digitized by an analog-to-digital converter under the command of the microprocessor and is stored in the data memory. The software in the microprocessor determines the relative distention of the bladder as a function of the propagated ultrasonic energy; and based on programmed scientific measurements and individual, anatomical, and behavioral characterists of the specific subject as contained in the program memory, sends out a signal to turn on any or all of the audible alarm, the visible alarm, the tactile alarm, and the remote wireless alarm
    corecore