15,199 research outputs found

    Correlations in Nuclear Matter

    Full text link
    We analyze the nuclear matter correlation properties in terms of the pair correlation function. To this aim we systematically compare the results for the variational method in the Lowest Order Constrained Variational (LOCV) approximation and for the Bruekner-Hartree-Fock (BHF) scheme. A formal link between the Jastrow correlation factor of LOCV and the Defect Function (DF) of BHF is established and it is shown under which conditions and approximations the two approaches are equivalent. From the numerical comparison it turns out that the two correlation functions are quite close, which indicates in particular that the DF is approximately local and momentum independent. The Equations of State (EOS) of Nuclear Matter in the two approaches are also compared. It is found that once the three-body forces (TBF) are introduced the two EOS are fairly close, while the agreement between the correlation functions holds with or without TBF.Comment: 11 figure

    Benchmark ultra-cool dwarfs in widely separated binary systems

    Full text link
    Ultra-cool dwarfs as wide companions to subgiants, giants, white dwarfs and main sequence stars can be very good benchmark objects, for which we can infer physical properties with minimal reference to theoretical models, through association with the primary stars. We have searched for benchmark ultra-cool dwarfs in widely separated binary systems using SDSS, UKIDSS, and 2MASS. We then estimate spectral types using SDSS spectroscopy and multi-band colors, place constraints on distance, and perform proper motions calculations for all candidates which have sufficient epoch baseline coverage. Analysis of the proper motion and distance constraints show that eight of our ultra-cool dwarfs are members of widely separated binary systems. Another L3.5 dwarf, SDSS 0832, is shown to be a companion to the bright K3 giant Eta Cancri. Such primaries can provide age and metallicity constraints for any companion objects, yielding excellent benchmark objects. This is the first wide ultra-cool dwarf + giant binary system identified.Comment: 4 pages, 3 figures, conference, "New Technologies for Probing the Diversity of Brown Dwarfs and Exoplanets", oral tal

    Multiplexable Kinetic Inductance Detectors

    Get PDF
    We are starting to investigate a novel multiplexable readout method that can be applied to a large class of superconducting pair-breaking detectors. This readout method is completely different from those currently used with STJ and TES detectors, and in principle could deliver large pixel counts, high sensitivity, and Fano-limited spectral resolution. The readout is based on the fact that the kinetic surface inductance L_s of a superconductor is a function of the density of quasiparticles n, even at temperatures far below T_c. An efficient way to measure changes in the kinetic inductance is to monitor the transmission phase of a resonant circuit. By working at microwave frequencies and using thin films, the kinetic inductance can be a significant part of the total inductance L, and the volume of the inductor can be made quite small, on the order of 1 µm^3. As is done with other superconducting detectors, trapping could be used to concentrate the quasiparticles into the small volume of the inductor. However, the most intriguing aspect of the concept is that passive frequency multiplexing could be used to read out ~10^3 detectors with a single HEMT amplifier

    Bacterial Cholangitis, Cholecystitis, or both in Dogs

    Get PDF
    BACKGROUND: Bacterial cholangitis and cholecystitis are rarely reported, poorly characterized diseases in the dog. OBJECTIVES: To characterize the clinical features of these conditions. ANIMALS: Twenty‐seven client‐owned dogs with bacterial cholangitis, cholecystitis, or both. METHODS: Multicenter, retrospective cases series of dogs with bacterial cholangitis, cholecystitis, or both, presenting January 2000 to June 2011 to 4 Veterinary Schools in Ireland/United Kingdom. Interrogation of hospital databases identified all cases with the inclusion criteria; histopathologically confirmed cholangitis or cholecystitis and bile culture/cytology results supporting a bacterial etiology. RESULTS: Twenty‐seven dogs met the inclusion criteria with approximately 460 hepatitis cases documented over the same study period. Typical clinical pathology findings were increases in liver enzyme activities (25/26), hyperbilirubinemia (20/26), and an inflammatory leukogram (21/24). Ultrasound findings, although nonspecific, aided decision‐making in 25/26 cases. The most frequent hepatobiliary bacterial isolates were Escherichia coli (n = 17; 16 cases), Enterococcus spp. (n = 8; 6 cases), and Clostridium spp. (n = 5; 5 cases). Antimicrobial resistance was an important feature of aerobic isolates; 10/16 E. coli isolates resistant to 3 or more antimicrobial classes. Biliary tract rupture complicated nearly one third of cases, associated with significant mortality (4/8). Discharged dogs had a guarded to fair prognosis; 17/18 alive at 2 months, although 5/10 re‐evaluated had persistent liver enzyme elevation 2–12 months later. CONCLUSION AND CLINICAL SIGNIFICANCE: Bacterial cholangitis and cholecystitis occur more frequently than suggested by current literature and should be considered in dogs presenting with jaundice and fever, abdominal pain, or an inflammatory leukogram or with ultrasonographic evidence of gallbladder abnormalities

    Position and energy-resolved particle detection using phonon-mediated microwave kinetic inductance detectors

    Get PDF
    We demonstrate position and energy-resolved phonon-mediated detection of particle interactions in a silicon substrate instrumented with an array of microwave kinetic inductance detectors (MKIDs). The relative magnitude and delay of the signal received in each sensor allow the location of the interaction to be determined with ≲ 1mm resolution at 30 keV. Using this position information, variations in the detector response with position can be removed, and an energy resolution of σ_E = 0.55 keV at 30 keV was measured. Since MKIDs can be fabricated from a single deposited film and are naturally multiplexed in the frequency domain, this technology can be extended to provide highly pixelized athermal phonon sensors for ∼1 kg scale detector elements. Such high-resolution, massive particle detectors would be applicable to rare-event searches such as the direct detection of dark matter, neutrinoless double-beta decay, or coherent neutrino-nucleus scattering

    Understanding students’ motivation towards proactive career behaviours through goal-setting theory and the job demands–resources model

    Get PDF
    The graduate labour market is highly competitive but little is known about why students vary in their development of employability. This study contributes to the literature by applying goal-setting theory and the job demands–resources model to investigate how motivational processes influence students’ proactive career behaviours. We tested four hypotheses using structural equation modelling and moderation/mediation analysis using a nested model approach; 432 undergraduates from 21 UK universities participated in this cross-sectional study. The results showed that students higher in mastery approach had greater perceived employability mediated by two proactive career behaviours (skill development and network building). Students’ career goal commitment was associated with all four proactive career behaviours (career planning, skill development, career consultation and network building). Students’ academic and employment workloads did not negatively impact their proactive career behaviours. University tutors and career services should therefore encourage students to set challenging career goals that reflect mastery approach

    CTMC calculations of electron capture and ionization in collisions of multiply charged ions with elliptical Rydberg atoms

    Get PDF
    We have performed classical trajectory Monte Carlo (CTMC) studies of electron capture and ionization in multiply charged (Q=8) ion-Rydberg atom collisions at intermediate impact velocities. Impact parallel to the minor and to the major axis, respectively, of the initial Kepler electron ellipse has been investigated. The important role of the initial electron momentum distribution found for singly charged ion impact is strongly disminished for higher projectile charge, while the initial spatial distribution remains important for all values of Q studied.Comment: 3 pages, 5 figure

    Quasiparticle Trapping in Microwave Kinetic Inductance Strip Detectors

    Get PDF
    Microwave Kinetic Inductance Detectors (MKIDs) are thin-film, superconducting resonators, which are attractive for making large detector arrays due to their natural frequency domain multiplexing at GHz frequencies. For X-ray to IR wavelengths, MKIDs can provide high-resolution energy and timing information for each incoming photon. By fabricating strip detectors consisting of a rectangular absorber coupled to MKIDs at each end, high quantum efficiency and spatial resolution can be obtained. A similar geometry is being pursued for phonon sensing in a WIMP dark matter detector. Various materials have been tested including tantalum, tin, and aluminum for the absorbing strip, and aluminum, titanium, and aluminum manganese for the MKID. Initial Ta/Al X-ray devices have shown energy resolutions as good as 62 eV at 6 keV. A Ta/Al UV strip detector with an energy resolution of 0.8 eV at 4.9 eV has been demonstrated, but we find the coupling of the MKIDs to the absorbers is unreliable for these thinner devices. We report on progress probing the thicknesses at which the absorber/MKID coupling begins to degrade by using a resonator to inject quasiparticles directly into the absorber. In order to eliminate the absorber/MKID interface, a modified design for implanted AlMn/Al UV strip detectors was developed, and results showing good transmission of quasiparticles from the absorber to MKID in these devices are presented

    The current population of benchmark brown dwarfs

    Full text link
    The number of brown dwarfs (BDs) now identified tops 700. Yet our understanding of these cool objects is still lacking, and models are struggling to accurately reproduce observations. What is needed is a method of calibrating the models, BDs whose properties (e.g. age, mass, distance, metallicity) that can be independently determined can provide such calibration. The ability to calculate properties based on observables is set to be of vital importance if we are to be able to measure the properties of fainter, more distant populations of BDs that near-future surveys will reveal, for which ground based spectroscopic studies will become increasingly difficult. We present here the state of the current population of age benchmark brown dwarfs.Comment: 2 pages, 1 figure, to appear in the conference proceedings "New Technologies for Probing the Diversity of Brown Dwarfs and Exoplanets", Shanghai, 19-24 July, 200

    Two new ultracool benchmark systems from WISE+2MASS

    Get PDF
    We have used the Two-Micron All-Sky Survey and the Wide-field Infrared Survey Explorer to look for ultracool dwarfs that are part of multiple systems containing main-sequence stars. We cross-matched L dwarf candidates from the surveys with Hipparcos and Gliese stars, finding two new systems. The first system, G255-34AB, is an L2 dwarf companion to a K8 star, at a distance of 36 pc. We estimate its bolometric luminosity as log L/L-circle dot = -3.78 +/- 0.045 and T-eff = 2080 +/- 260 K. The second system, GJ499ABC, is a triple, with an L5 dwarf as a companion to a binary with an M4 and K5 star. These two new systems bring the number of L dwarf plus main-sequence star multiple systems to 24, which we discuss. We consider the binary fraction for L dwarfs and main-sequence stars, and further assess possible unresolved multiplicity within the full companion sample. This analysis shows that some of the L dwarfs in this sample might actually be unresolved binaries themselves, since their M-J appears to be brighter than the expected for their spectral types.Peer reviewe
    corecore