67 research outputs found

    Tympanic Versus Rectal Thermometry in Pregnant Women

    Full text link
    To assess the accuracy of the tympanic membrane thermometer for use with pregnant women. Design : Cross-sectional descriptive study. Setting : A major medical center in the midwestern United States. Participants : Thirty-three hospitalized, afebrile pregnant women. Main outcome measures : Tympanic membrane thermometers and glass mercury thermometers were used to measure body temperature at the ear and rectum, respectively. The results were compared using two statistical methods: the Pearson correlation coefficient and a new technique suggested by Bland and Altman (1986). Results : Auditory canal temperature measured by a tympanic membrane thermometer correlated with rectal temperature as measured by a glass mercury thermometer ( r = 0.38, p = 0.01). Thus, the tympanic membrane thermometer is acceptable for monitoring the body temperature of pregnant women. However, the device's estimation of rectal temperature is not clinically reliable. Conclusions : Tympanic membrane thermometers, when applied with direct measures, are acceptable for use with pregnant women. It is not recommended that the rectal estimate mode be used with pregnant women.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/72991/1/j.1552-6909.1995.tb02556.x.pd

    Differences in pain, function and coping in Multidimensional Pain Inventory subgroups of chronic back pain: a one-group pretest-posttest study

    Get PDF
    Contains fulltext : 97819.pdf (publisher's version ) (Open Access)BACKGROUND: Patients with non-specific back pain are not a homogeneous group but heterogeneous with regard to their bio-psycho-social impairments. This study examined a sample of 173 highly disabled patients with chronic back pain to find out how the three subgroups based on the Multidimensional Pain Inventory (MPI) differed in their response to an inpatient pain management program. METHODS: Subgroup classification was conducted by cluster analysis using MPI subscale scores at entry into the program. At program entry and at discharge after four weeks, participants completed the MPI, the MOS Short Form-36 (SF-36), the Hospital Anxiety and Depression Scale (HADS), and the Coping Strategies Questionnaire (CSQ). Pairwise analyses of the score changes of the mentioned outcomes of the three MPI subgroups were performed using the Mann-Whitney-U-test for significance. RESULTS: Cluster analysis identified three MPI subgroups in this highly disabled sample: a dysfunctional, interpersonally distressed and an adaptive copers subgroup. The dysfunctional subgroup (29% of the sample) showed the highest level of depression in SF-36 mental health (33.4 +/- 13.9), the interpersonally distressed subgroup (35% of the sample) a modest level of depression (46.8 +/- 20.4), and the adaptive copers subgroup (32% of the sample) the lowest level of depression (57.8 +/- 19.1). Significant differences in pain reduction and improvement of mental health and coping were observed across the three MPI subgroups, i.e. the effect sizes for MPI pain reduction were: 0.84 (0.44-1.24) for the dysfunctional subgroup, 1.22 (0.86-1.58) for the adaptive copers subgroup, and 0.53 (0.24-0.81) for the interpersonally distressed subgroup (p = 0.006 for pairwise comparison). Significant score changes between subgroups concerning activities and physical functioning could not be identified. CONCLUSIONS: MPI subgroup classification showed significant differences in score changes for pain, mental health and coping. These findings underscore the importance of assessing individual differences to understand how patients adjust to chronic back pain

    Reexamining age, race, site, and thermometer type as variables affecting temperature measurement in adults – A comparison study

    Get PDF
    BACKGROUND: As a result of the recent international vigilance regarding disease assessment, accurate measurement of body temperature has become increasingly important. Yet, trusted low-tech, portable mercury glass thermometers are no longer available. Thus, comparing accuracy of mercury-free thermometers with mercury devices is essential. Study purposes were 1) to examine age, race, site as variables affecting temperature measurement in adults, and 2) to compare clinical accuracy of low-tech Galinstan-in-glass device to mercury-in-glass at oral, axillary, groin, and rectal sites in adults. METHODS: Setting 176 bed accredited healthcare facility, rural northwest US Participants Convenience sample (N = 120) of hospitalized persons ≥ 18 years old. Instruments Temperatures (°F) measured at oral, skin (simultaneous), immediately followed by rectal sites with four each mercury-glass (BD) and Galinstan-glass (Geratherm) thermometers; 10 minute dwell times. RESULTS: Participants averaged 61.6 years (SD 17.9), 188 pounds (SD 55.3); 61% female; race: 85% White, 8.3% Native Am., 4.2% Hispanic, 1.7 % Asian, 0.8% Black. For both mercury and Galinstan-glass thermometers, within-subject temperature readings were highest rectally; followed by oral, then skin sites. Galinstan assessments demonstrated rectal sites 0.91°F > oral and ≅ 1.3°F > skin sites. Devices strongly correlated between and across sites. Site difference scores between devices showed greatest variability at skin sites; least at rectal site. 95% confidence intervals of difference scores by site (°F): oral (0.142 – 0.265), axilla (0.167 – 0.339), groin (0.037 – 0.321), and rectal (-0.111 – 0.111). Race correlated with age, temperature readings each site and device. CONCLUSION: Temperature readings varied by age, race. Mercury readings correlated with Galinstan thermometer readings at all sites. Site mean differences between devices were considered clinically insignificant. Still considered the gold standard, mercury-glass thermometers may no longer be available worldwide. Therefore, mercury-free, environmentally safe low-tech Galinstan-in-glass may be an appropriate replacement. This is especially important as we face new, internationally transmitted diseases

    Successful use of ECLS in cardiopulmonary failure due to aluminum phosphide poising

    Get PDF
    The use of ECLS in the treatment of poisoned patients has been recently reviewed by de Lange et al. [1], but a case of aluminum phosphide poising supported by ECLS has not been described yet. We want to report a successful support with ECLS in a 6 year old child with severe cardiovascular failure due to aluminum phosphide poisin
    • …
    corecore