985 research outputs found
Restriction on the energy and luminosity of e+e- storage rings due to beamstrahlung
The role of beamstrahlung in high-energy e+e- storage-ring colliders (SRCs)
is examined. Particle loss due to the emission of single energetic
beamstrahlung photons is shown to impose a fundamental limit on SRC
luminosities at energies 2E_0 >~ 140 GeV for head-on collisions and 2E_0 >~ 40
GeV for crab-waist collisions. With beamstrahlung taken into account, we
explore the viability of SRCs in the E_0=240-500 GeV range, which is of
interest in the precision study of the Higgs boson. At 2E_0=240 GeV, SRCs are
found to be competitive with linear colliders; however, at 2E_0=400-500 GeV,
the attainable SRC luminosity would be a factor 15-25 smaller than desired.Comment: Latex, 5 pages. v2 differs only by minor changes is abstract and
introduction, one reference is added. v3 corresponds to the paper published
in PR
The CLIC Programme: Towards a Staged e+e- Linear Collider Exploring the Terascale : CLIC Conceptual Design Report
This report describes the exploration of fundamental questions in particle
physics at the energy frontier with a future TeV-scale e+e- linear collider
based on the Compact Linear Collider (CLIC) two-beam acceleration technology. A
high-luminosity high-energy e+e- collider allows for the exploration of
Standard Model physics, such as precise measurements of the Higgs, top and
gauge sectors, as well as for a multitude of searches for New Physics, either
through direct discovery or indirectly, via high-precision observables. Given
the current state of knowledge, following the observation of a 125 GeV
Higgs-like particle at the LHC, and pending further LHC results at 8 TeV and 14
TeV, a linear e+e- collider built and operated in centre-of-mass energy stages
from a few-hundred GeV up to a few TeV will be an ideal physics exploration
tool, complementing the LHC. In this document, an overview of the physics
potential of CLIC is given. Two example scenarios are presented for a CLIC
accelerator built in three main stages of 500 GeV, 1.4 (1.5) TeV, and 3 TeV,
together with operating schemes that will make full use of the machine capacity
to explore the physics. The accelerator design, construction, and performance
are presented, as well as the layout and performance of the experiments. The
proposed staging example is accompanied by cost estimates of the accelerator
and detectors and by estimates of operating parameters, such as power
consumption. The resulting physics potential and measurement precisions are
illustrated through detector simulations under realistic beam conditions.Comment: 84 pages, published as CERN Yellow Report
https://cdsweb.cern.ch/record/147522
Comparison of Frequency of Periprocedural Myocardial Infarction in Patients With and Without Diabetes Mellitus to Those With Previously Unknown but Elevated Glycated Hemoglobin Levels (from the TWENTE Trial)
In patients without a history of diabetes mellitus, increased levels of glycated hemoglobin (HbA1c) are associated with higher cardiovascular risk. The relation between undetected diabetes and clinical outcome after percutaneous coronary intervention is unknown. To investigate whether these patients may have an increased risk of periprocedural myocardial infarction (PMI), the most frequent adverse event after percutaneous coronary intervention, we assessed patients of the TWENTE trial (a randomized, controlled, second-generation drug-eluting stent trial) in whom HbA1c data were available. Patients were classified as known diabetics or patients without a history of diabetes who were subdivided into undetected diabetics (HbA1c ≥6.5%) and nondiabetics (HbA1c <6.5%). Systematic measurement of cardiac biomarkers and electrocardiographic assessment were performed. One-year clinical outcome was also compared. Of 626 patients, 44 (7%) were undetected diabetics, 181 (29%) were known diabetics, and 401 (64%) were nondiabetics. In undetected diabetics the PMI rate was higher than in nondiabetics (13.6% vs 3.7%, p = 0.01) and known diabetics (13.6% vs 6.1%, p = 0.11). Multivariate analysis adjusting for covariates confirmed a significantly higher PMI risk in undetected diabetics compared to nondiabetics (odds ratio 6.13, 95% confidence interval 2.07 to 18.13, p = 0.001) and known diabetics (odds ratio 3.73, 95% confidence interval 1.17 to 11.89, p = 0.03). After 1 year, target vessel MI rate was significantly higher in undetected diabetics (p = 0.02) than in nondiabetics, which was related mainly to differences in PMI. Target vessel failure was numerically larger in unknown diabetics than in nondiabetics, but this difference did not reach statistical significance (13.6% vs 8.0%, p = 0.25). In conclusion, undetected diabetics were shown to have an increased risk of PMI
R&D Proposal Development of Micro-Pattern Gas Detector Technologies
Development of advanced gas-avalanche detector technologies and associated electronic-readout systems for applications in basic and applied researc
Unveiling the roles of temporal periodicity, the spatial environment and behavioural modes in terrestrial animal movement
Background: Animal movement arises from complex interactions between animals and their heterogeneous environment. To better understand the movement process, it can be divided into behavioural, temporal and spatial components. Although methods exist to address those various components, it remains challenging to integrate them in a single movement analysis. Methods: We present an analytic workflow that integrates the behavioural, temporal and spatial components of the movement process and their interactions, which also allows for the assessment of the relative importance of those components. We construct a daily cyclic covariate to represent temporally cyclic movement patterns, such as diel variation in activity, and combine the three components in a multi-modal Hidden Markov Model framework using existing methods and R functions. We compare the trends and statistical fits of models that include or exclude any of the behavioural, spatial and temporal components, and perform variance partitioning on the model predictions that included all components to assess their relative importance to the movement process, both in isolation and in interaction. Results: We apply our workflow to a case study on the movements of plains zebra, blue wildebeest and eland antelope in a South African reserve. Behavioural modes impacted movement the most, followed by diel rhythms and then the spatial environment (viz. tree cover and terrain slope). Interactions between the components often explained more of the movement variation than the marginal effect of the spatial environment did on its own. Omitting components from the analysis led either to the inability to detect relationships between input and response variables, resulting in overgeneralisations when drawing conclusions about the movement process, or to detections of questionable relationships that appeared to be spurious. Conclusions: Our analytic workflow can be used to integrate the behavioural, temporal and spatial components of the movement process and quantify their relative contributions, thereby preventing incomplete or overly generic ecological interpretations. We demonstrate that understanding the drivers of animal movement, and ultimately the ecological phenomena that emerge from it, critically depends on considering the various components of the movement process, and especially the interactions between them.</p
The Time Structure of Hadronic Showers in highly granular Calorimeters with Tungsten and Steel Absorbers
The intrinsic time structure of hadronic showers influences the timing
capability and the required integration time of hadronic calorimeters in
particle physics experiments, and depends on the active medium and on the
absorber of the calorimeter. With the CALICE T3B experiment, a setup of 15
small plastic scintillator tiles read out with Silicon Photomultipliers, the
time structure of showers is measured on a statistical basis with high spatial
and temporal resolution in sampling calorimeters with tungsten and steel
absorbers. The results are compared to GEANT4 (version 9.4 patch 03)
simulations with different hadronic physics models. These comparisons
demonstrate the importance of using high precision treatment of low-energy
neutrons for tungsten absorbers, while an overall good agreement between data
and simulations for all considered models is observed for steel.Comment: 24 pages including author list, 9 figures, published in JINS
Shower development of particles with momenta from 15 GeV to 150 GeV in the CALICE scintillator-tungsten hadronic calorimeter
We present a study of showers initiated by electrons, pions, kaons, and
protons with momenta from 15 GeV to 150 GeV in the highly granular CALICE
scintillator-tungsten analogue hadronic calorimeter. The data were recorded at
the CERN Super Proton Synchrotron in 2011. The analysis includes measurements
of the calorimeter response to each particle type as well as measurements of
the energy resolution and studies of the longitudinal and radial shower
development for selected particles. The results are compared to Geant4
simulations (version 9.6.p02). In the study of the energy resolution we include
previously published data with beam momenta from 1 GeV to 10 GeV recorded at
the CERN Proton Synchrotron in 2010.Comment: 35 pages, 21 figures, 8 table
- …
