985 research outputs found

    Restriction on the energy and luminosity of e+e- storage rings due to beamstrahlung

    Full text link
    The role of beamstrahlung in high-energy e+e- storage-ring colliders (SRCs) is examined. Particle loss due to the emission of single energetic beamstrahlung photons is shown to impose a fundamental limit on SRC luminosities at energies 2E_0 >~ 140 GeV for head-on collisions and 2E_0 >~ 40 GeV for crab-waist collisions. With beamstrahlung taken into account, we explore the viability of SRCs in the E_0=240-500 GeV range, which is of interest in the precision study of the Higgs boson. At 2E_0=240 GeV, SRCs are found to be competitive with linear colliders; however, at 2E_0=400-500 GeV, the attainable SRC luminosity would be a factor 15-25 smaller than desired.Comment: Latex, 5 pages. v2 differs only by minor changes is abstract and introduction, one reference is added. v3 corresponds to the paper published in PR

    The CLIC Programme: Towards a Staged e+e- Linear Collider Exploring the Terascale : CLIC Conceptual Design Report

    Full text link
    This report describes the exploration of fundamental questions in particle physics at the energy frontier with a future TeV-scale e+e- linear collider based on the Compact Linear Collider (CLIC) two-beam acceleration technology. A high-luminosity high-energy e+e- collider allows for the exploration of Standard Model physics, such as precise measurements of the Higgs, top and gauge sectors, as well as for a multitude of searches for New Physics, either through direct discovery or indirectly, via high-precision observables. Given the current state of knowledge, following the observation of a 125 GeV Higgs-like particle at the LHC, and pending further LHC results at 8 TeV and 14 TeV, a linear e+e- collider built and operated in centre-of-mass energy stages from a few-hundred GeV up to a few TeV will be an ideal physics exploration tool, complementing the LHC. In this document, an overview of the physics potential of CLIC is given. Two example scenarios are presented for a CLIC accelerator built in three main stages of 500 GeV, 1.4 (1.5) TeV, and 3 TeV, together with operating schemes that will make full use of the machine capacity to explore the physics. The accelerator design, construction, and performance are presented, as well as the layout and performance of the experiments. The proposed staging example is accompanied by cost estimates of the accelerator and detectors and by estimates of operating parameters, such as power consumption. The resulting physics potential and measurement precisions are illustrated through detector simulations under realistic beam conditions.Comment: 84 pages, published as CERN Yellow Report https://cdsweb.cern.ch/record/147522

    Comparison of Frequency of Periprocedural Myocardial Infarction in Patients With and Without Diabetes Mellitus to Those With Previously Unknown but Elevated Glycated Hemoglobin Levels (from the TWENTE Trial)

    Get PDF
    In patients without a history of diabetes mellitus, increased levels of glycated hemoglobin (HbA1c) are associated with higher cardiovascular risk. The relation between undetected diabetes and clinical outcome after percutaneous coronary intervention is unknown. To investigate whether these patients may have an increased risk of periprocedural myocardial infarction (PMI), the most frequent adverse event after percutaneous coronary intervention, we assessed patients of the TWENTE trial (a randomized, controlled, second-generation drug-eluting stent trial) in whom HbA1c data were available. Patients were classified as known diabetics or patients without a history of diabetes who were subdivided into undetected diabetics (HbA1c ≥6.5%) and nondiabetics (HbA1c <6.5%). Systematic measurement of cardiac biomarkers and electrocardiographic assessment were performed. One-year clinical outcome was also compared. Of 626 patients, 44 (7%) were undetected diabetics, 181 (29%) were known diabetics, and 401 (64%) were nondiabetics. In undetected diabetics the PMI rate was higher than in nondiabetics (13.6% vs 3.7%, p = 0.01) and known diabetics (13.6% vs 6.1%, p = 0.11). Multivariate analysis adjusting for covariates confirmed a significantly higher PMI risk in undetected diabetics compared to nondiabetics (odds ratio 6.13, 95% confidence interval 2.07 to 18.13, p = 0.001) and known diabetics (odds ratio 3.73, 95% confidence interval 1.17 to 11.89, p = 0.03). After 1 year, target vessel MI rate was significantly higher in undetected diabetics (p = 0.02) than in nondiabetics, which was related mainly to differences in PMI. Target vessel failure was numerically larger in unknown diabetics than in nondiabetics, but this difference did not reach statistical significance (13.6% vs 8.0%, p = 0.25). In conclusion, undetected diabetics were shown to have an increased risk of PMI

    Unveiling the roles of temporal periodicity, the spatial environment and behavioural modes in terrestrial animal movement

    Get PDF
    Background: Animal movement arises from complex interactions between animals and their heterogeneous environment. To better understand the movement process, it can be divided into behavioural, temporal and spatial components. Although methods exist to address those various components, it remains challenging to integrate them in a single movement analysis. Methods: We present an analytic workflow that integrates the behavioural, temporal and spatial components of the movement process and their interactions, which also allows for the assessment of the relative importance of those components. We construct a daily cyclic covariate to represent temporally cyclic movement patterns, such as diel variation in activity, and combine the three components in a multi-modal Hidden Markov Model framework using existing methods and R functions. We compare the trends and statistical fits of models that include or exclude any of the behavioural, spatial and temporal components, and perform variance partitioning on the model predictions that included all components to assess their relative importance to the movement process, both in isolation and in interaction. Results: We apply our workflow to a case study on the movements of plains zebra, blue wildebeest and eland antelope in a South African reserve. Behavioural modes impacted movement the most, followed by diel rhythms and then the spatial environment (viz. tree cover and terrain slope). Interactions between the components often explained more of the movement variation than the marginal effect of the spatial environment did on its own. Omitting components from the analysis led either to the inability to detect relationships between input and response variables, resulting in overgeneralisations when drawing conclusions about the movement process, or to detections of questionable relationships that appeared to be spurious. Conclusions: Our analytic workflow can be used to integrate the behavioural, temporal and spatial components of the movement process and quantify their relative contributions, thereby preventing incomplete or overly generic ecological interpretations. We demonstrate that understanding the drivers of animal movement, and ultimately the ecological phenomena that emerge from it, critically depends on considering the various components of the movement process, and especially the interactions between them.</p

    The Time Structure of Hadronic Showers in highly granular Calorimeters with Tungsten and Steel Absorbers

    Get PDF
    The intrinsic time structure of hadronic showers influences the timing capability and the required integration time of hadronic calorimeters in particle physics experiments, and depends on the active medium and on the absorber of the calorimeter. With the CALICE T3B experiment, a setup of 15 small plastic scintillator tiles read out with Silicon Photomultipliers, the time structure of showers is measured on a statistical basis with high spatial and temporal resolution in sampling calorimeters with tungsten and steel absorbers. The results are compared to GEANT4 (version 9.4 patch 03) simulations with different hadronic physics models. These comparisons demonstrate the importance of using high precision treatment of low-energy neutrons for tungsten absorbers, while an overall good agreement between data and simulations for all considered models is observed for steel.Comment: 24 pages including author list, 9 figures, published in JINS

    Shower development of particles with momenta from 15 GeV to 150 GeV in the CALICE scintillator-tungsten hadronic calorimeter

    Full text link
    We present a study of showers initiated by electrons, pions, kaons, and protons with momenta from 15 GeV to 150 GeV in the highly granular CALICE scintillator-tungsten analogue hadronic calorimeter. The data were recorded at the CERN Super Proton Synchrotron in 2011. The analysis includes measurements of the calorimeter response to each particle type as well as measurements of the energy resolution and studies of the longitudinal and radial shower development for selected particles. The results are compared to Geant4 simulations (version 9.6.p02). In the study of the energy resolution we include previously published data with beam momenta from 1 GeV to 10 GeV recorded at the CERN Proton Synchrotron in 2010.Comment: 35 pages, 21 figures, 8 table
    corecore