70 research outputs found

    Vitamin K2 and its Impact on Tooth Epigenetics

    Get PDF
    The impact of nutritional signals plays an important role in systemic-based «models» of dental caries. Present hypotheses now focus both on the oral environment and other organs, like the nervous system and brain. The tooth is subjected to shear forces, nourishing and cleansing, and its present “support system” (the hypothalamus/parotid axis) relays endocrine signaling to the parotid gland. Sugar consumption enhances hypothalamic oxidative stress (ROS), reversing dentinal fluid flow, thus creating an enhanced vulnerability to the oral bacterial flora. The acid, produced by the oral bacterial flora, then leads to erosion of the dentine, and an irreversible loss of dental enamel layers. This attack brings about inflammatory responses, yielding metalloproteinase-based “dissolution”. However, vitamin K2 (i.e. MK-4/MK-7) may come to the rescue with its antioxidant property, locally (mouth cavity) or systemically (via the brain), thus sustaining/preserving hormone-induced dentinal fluid flow (encompassing oxidative stress) and boosting/magnifying bodily inflammatory responses. However, sugars may also reduce the tooth’s natural defences through endocrine signaling, thus enhancing acid-supported enamel dentine erosion. Vitamin K2 sustains and improves the salivary buffering capacity via its impact on the secretion/flow of calcium and inorganic phosphates. Interestingly, primitive cultures’ diets (low-sugar and high-K2 diets) preserve dental health

    Redefining biomaterial biocompatibility: challenges for artificial intelligence and text mining

    Get PDF
    The surge in ‘Big data’ has significantly influenced biomaterials research and development, with vast data volumes emerging from clinical trials, scientific literature, electronic health records, and other sources. Biocompatibility is essential in developing safe medical devices and biomaterials to perform as intended without provoking adverse reactions. Therefore, establishing an artificial intelligence (AI)-driven biocompatibility definition has become decisive for automating data extraction and profiling safety effectiveness. This definition should both reflect the attributes related to biocompatibility and be compatible with computational data-mining methods. Here, we discuss the need for a comprehensive and contemporary definition of biocompatibility and the challenges in developing one. We also identify the key elements that comprise biocompatibility, and propose an integrated biocompatibility definition that enables data-mining approaches.Peer ReviewedPostprint (published version

    Is There a Better Biomaterial for Dental Implants than Titanium?—A Review and Meta-Study Analysis

    No full text
    This article focuses on preclinical studies and reviews the available evidence from the literature on dental implant and abutment materials in the last decade. Specifically, different peri-implantitis materials and how surface modifications may affect the peri-implant soft-tissue seal and subsequently delay or hinder peri-implantitis are examined. This review analyzed more than 30 studies that were Randomized Controlled Trials (RCTs), Controlled Clinical Trials (CCTs), or prospective case series (CS) with at least six months of follow-up. Meta-analyses were performed to make a comparison between different implant materials (titanium vs. zirconia), including impact on bone changes, probing depth, plaque levels, and peri-implant mucosal inflammation, as well as how the properties of the implant material and surface modifications would affect the peri-implant soft-tissue seal and peri-implant health conditions. However, there was no clear evidence regarding whether titanium is better than other implant materials. Clinical evidence suggests no difference between different implant materials in peri-implant bone stability. The metal analysis offered a statistically significant advantage of zirconia implants over titanium regarding developing a favorable response to the alveolar bon

    Comparison of titanium dioxide scaffold with commercial bone graft materials through micro-finite element modelling in flow perfusion

    No full text
    TiO2 scaffolds have previously shown to have promising osteoconductive properties in previous in vivo experiments. Appropriate mechanical stimuli can further promote this osteoconductive behaviour. However, the complex mechanical environment and the mechanical stimuli enhancing bone regeneration for porous bioceramics have not yet been fully elucidated. This paper aims to compare and evaluate mechanical environment of TiO2 scaffold with three commercial CaP biomaterials, i.e. Bio-Oss, Cerabone and Maxresorb under simulated perfusion culture conditions. The solid phase and fluid phase were modelled as linear elastic material and Newtonian fluid, respectively. The mechanical stimulus was analysed within these porous scaffolds quantitatively. The results showed that the TiO2 had nearly heterogeneous stress distributions, however lower effective Young’s modulus than Cerabone and Maxresorb. The permeability and wall shear stress (WSS) for the TiO2 scaffold was significantly higher than other commercial bone substitute materials. Maxresorb and Bio-Oss showed lowest permeability and local areas of very high WSS. The detailed description of the mechanical performance of these scaffolds could help researchers to predict cell behaviour and to select the most appropriate scaffold for different in vitro and in vivo performances. © 2018 Springer Verla

    Validation of contralateral premolars as the substrate for endodontic comparison studies

    No full text
    AIM: To use micro-CT technology and metrology software to validate the use of contralateral premolars as samples in endodontic comparison studies by comparing them before and after canal instrumentation with one instrumentation system. Furthermore, to determine if contralateral premolar roots will yield non-significantly different outcomes regarding shaping ability (volume), degree of twisting, and three-dimensional shape changes. The null-hypothesis (H0 ) is that there are no differences between the contralateral premolar roots pre- or post-instrumentation. METHODOLOGY: Twenty-eight extracted human contralateral premolars (n=44 contralateral roots) from 12 donor patients were scanned with microcomputed tomography before and after instrumentation. Root canal lengths (RCL) were measured visually using a dental operating microscope, electronic apex locator, and micro-CT scans. Data were analyzed statistically for differences between pre- and post-instrumentation. RESULTS: Instrumentation increased the volume of the canals significantly (P0.05). There was no significant difference (P>0.05) in the shape deviation analysis between contralateral pairs. There was no significant difference (P>0.05) for root canal length between the contralateral pairs for any of the three endometric methods. CONCLUSION: Contralateral premolar root canals were associated with similar changes in terms of volume, three-dimensional shape, and degree of twisting from pre- to post-instrumentation. There was no difference between the contralateral premolar root pairs pre- and post-instrumentation, and the study validates contralateral premolars as samples for root canal comparison studies. The null-hypothesis (H0 ) could not be rejected. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved. This is the peer reviewed version of the following article: Johnsen GF, Sunde PT, Haugen HJ. Validation of contralateral premolars as the substrate for endodontic comparison studies. International Endodontic Journal. which has been published in final form at https://doi.org/10.1111/iej.12902. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Self-Archiving

    Osteoblasts in a Perfusion Flow Bioreactor—Tissue Engineered Constructs of TiO2 Scaffolds and Cells for Improved Clinical Performance

    No full text
    Combining biomaterial scaffolds with cells serves as a promising strategy for engineering critical size defects; however, homogenous cellular growth within large scaffolds is challenging. Mechanical stimuli can enhance bone regeneration by modulating cellular growth and differentiation. Here, we compare dynamic seeding in a perfusion flow bioreactor with static seeding for a synthetic bone scaffold for up to 21 days using the cell line MC3T3-E1 and primary human osteoblast, confocal laser scanning microscopy, and real-time reverse transcriptase-polymerase chain reaction. The secretion of bone-related proteins was quantified using multiplex immunoassays. Dynamic culture improved cellular distribution through the TiO2 scaffold and induced a five-fold increase in cell number after 21 days. The relative mRNA expression of osteopontin of MC3T3-E1 was 40-fold enhanced after 7 and 21 days at a flow rate of 0.08 mL/min, and that of collagen type I alpha I expression was 18-fold after 21 days. A flow rate of 0.16 mL/min was 10-fold less effective. Dynamic culture increased the levels of dickkopf-related protein 1 (60-fold), osteoprotegrin (29-fold), interleukin-6 (23-fold), interleukin-8 (36-fold), monocyte chemoattractant protein 1 (28-fold) and vascular endothelial growth factor (6-fold) in the medium of primary human osteoblasts after 21 days compared to static seeding. The proposed method may have clinical potential for bone tissue engineering

    The Antibacterial and Cytotoxic Effects of Silver Nanoparticles Coated Titanium Implants: A Narrative Review

    No full text
    Nanotechnology has become an emerging research field with numerous biomedical scientific applications. Silver possesses bactericidal activities that have been harnessed for centuries; however, there is a concern about the toxic effects of silver nanoparticles. This paper aims to provide an overview of silver-treated dental implants and discuss their potential to reduce the prevalence of peri-implant diseases. An electronic search was performed using PubMed. After screening, data extraction was performed on the 45 remaining articles using inclusion and exclusion criteria. Most of the articles demonstrated that silver nanoparticles embedded in a coating layer and/or on surface-treated titanium exhibit sound antibacterial effects and biocompatibility. Most of the reviewed studies revealed that silver nanoparticles on dental implant surfaces reduced cytotoxicity but provided a prolonged antibacterial effect. The cytotoxicity and antibacterial effect are closely linked to how the silver nanoparticles are released from the titanium surfaces, where a slower release increases cell viability and proliferation. However, to improve the clinical translation, there is still a need for more studies, especially evaluating the long-term systemic effects and studies recreating the conditions in the oral cavity

    Use of 3D-printed polylactic acid/bioceramic composite scaffolds for bone tissue engineering in preclinical in vivo studies: A systematic review

    Get PDF
    3D-printed composite scaffolds have emerged as an alternative to deal with existing limitations when facing bone reconstruction. The aim of the study was to systematically review the feasibility of using PLA/bioceramic composite scaffolds manufactured by 3D printing technologies as bone grafting materials in preclinical in vivo studies. Electronic databases were searched using specific search terms, and thirteen manuscripts were selected after screening. The synthesis of the scaffolds was carried out using mainly extrusion-based techniques. Likewise, hydroxyapatite was the most used bioceramic for synthesizing composites with a PLA matrix. Among the selected studies, seven were conducted in rats and six in rabbits, but the high variability that exists regarding the experimental process made it difficult to compare them. Regarding the results, PLA/Bioceramic composite scaffolds have shown to be biocompatible and mechanically resistant. Preclinical studies elucidated the ability of the scaffolds to be used as bone grafts, allowing bone growing without adverse reactions. In conclusion, PLA/Bioceramics scaffolds have been demonstrated to be a promising alternative for treating bone defects. Nevertheless, more care should be taken when designing and performing in vivo trials, since the lack of standardization of the processes, which prevents the comparison of the results and reduces the quality of the information. Statement of Significance 3D-printed polylactic acid/bioceramic composite scaffolds have emerged as an alternative to deal with existing limitations when facing bone reconstruction. Since preclinical in vivo studies with animal models represent a mandatory step for clinical translation, the present manuscript analyzed and discussed not only those aspects related to the selection of the bioceramic material, the synthesis of the implants and their characterization. But provides a new approach to understand how the design and perform of clinical trials, as well as the selection of the analysis methods, may affect the obtained results, by covering authors’ knowledgebase from veterinary medicine to biomaterial science. Thus, this study aims to systematically review the feasibility of using polylactic acid/bioceramic scaffolds as grafting materials in preclinical trials.I.A. acknowledges the XUNTA de Galicia for his pre-doctoral contract (Ref. ED481A 2021/137) from Galician Government Consellería de Cultura, Educación e UniversidadesS

    Exploiting novel sterilization techniques for porous polyurethane scaffolds

    Get PDF
    Porous polyurethane (PU) structures raise in- creasing interest as scaffolds in tissue engineering appli- cations. Understanding the effects of sterilization on their properties is mandatory to assess their potential use in the clinical practice. The aim of this work is the evaluation of the effects of two innovative sterilization techniques (i.e. plasma, Sterrad system, and ozone) on the morphological, chemico-physical and mechanical properties of a PU foam synthesized by gas foaming, using water as expanding agent. In addition, possible toxic effects of the sterilization were evaluated by in vitro cytotoxicity tests. Plasma ster- ilization did not affect the morphological and mechanical properties of the PU foam, but caused at some extent degradative phenomena, as detected by infrared spec- troscopy. Ozone sterilization had a major effect on foam morphology, causing the formation of new small pores, and stronger degradation and oxidation on the structure of the material. These modifications affected the mechanical properties of the sterilized PU foam too. Even though, no cytotoxic effects were observed after both plasma and ozone sterilization, as confirmed by the good values of cell viability assessed by Alamar Blue assay. The results here obtained can help in understanding the effects of steril- ization procedures on porous polymeric scaffolds, and how the scaffold morphology, in particular porosity, can influ- ence the effects of sterilization, and viceversa

    Bone grafts: which is the ideal biomaterial?

    No full text
    Abstract Bovine xenograft materials, followed by synthetic biomaterials, which unfortunately still lack documented predictability and clinical performance, dominate the market for the cranio‐maxillofacial area. In Europe, new stringent regulations are expected to further limit the allograft market in the future Aim Within this narrative review, we discuss possible future biomaterials for bone replacement. Scientific Rationale for Study Although the bone graft (BG) literature is overflooded, only a handful of new BG substitutes are clinically available. Laboratory studies tend to focus on advanced production methods and novel biomaterial features, which can be costly to produce. Practical Implications In this review, we ask why such a limited number of BGs are clinically available when compared to extensive laboratory studies. We also discuss what features are needed for an ideal BG. Results We have identified the key properties of current bone substitutes and have provided important information to guide clinical decision‐making and generate new perspectives on bone substitutes. Our results indicated that different mechanical and biological properties are needed despite each having a broad spectrum of variations. Conclusions We foresee bone replacement composite materials with higher levels of bioactivity, providing an appropriate balance between bioabsorption and volume maintenance for achieving ideal bone remodelling
    • 

    corecore