3,415 research outputs found

    Characterization of the interface region during the agglomeration of silicon nanocrystals in silicon dioxide

    Get PDF
    Si nanocrystals embedded in thermally grown SiO2 have been annealed at temperatures between 400 and 900 degreesC in a variety of atmospheres. Positron annihilation spectroscopy has been employed to study changes in the interface regions between nanocrystalline Si (nc-Si) and SiO2 with the support of photoluminescence measurements. We find that nitrogen and oxygen are trapped in the voids around nc-Si at low annealing temperatures. High-temperature annealing during the formation of nc-Si causes hydrogen originally residing in the SiO2/substrate region to enter the SiO2 structure. Hydrogen diffuse back to the SiO2/substrate region on annealing in vacuum at 400 degreesC because no other impurities block its diffusion channels. At annealing temperatures above 700 degreesC, both nitrogen and oxygen react with nc-Si, resulting in a volume increase. This introduces stress in the SiO2 matrix, which is relaxed by the shrinkage of its intrinsic open volume. The present data suggest that nitrogen suppresses Si diffusion in SiO2, so that the agglomeration of nc-Si is slower during annealing in nitrogen than in oxygen or vacuum.</p

    Enhancement of the high-field critical current density of superconducting MgB2 by proton irradiation

    Full text link
    A relatively high critical temperature, Tc, approaching 40 K, places the recently-discovered superconductor magnesium diboride (MgB2) intermediate between the families of low- and copper-oxide-based high-temperature superconductors (HTS). Supercurrent flow in MgB2 is unhindered by grain boundaries, unlike the HTS materials. Thus, long polycrystalline MgB2 conductors may be easier to fabricate, and so could fill a potentially important niche of applications in the 20 to 30 K temperature range. However, one disadvantage of MgB2 is that in bulk material the critical current density, Jc, appears to drop more rapidly with increasing magnetic field than it does in the HTS phases. The magnitude and field dependence of Jc are related to the presence of structural defects that can "pin" the quantised magnetic vortices that permeate the material, and prevent them from moving under the action of the Lorentz force. Vortex studies suggest that it is the paucity of suitable defects in MgB2 that causes the rapid decay of Jc with field. Here we show that modest levels of atomic disorder, induced by proton irradiation, enhance the pinning, and so increase Jc significantly at high fields. We anticipate that chemical doping or mechanical processing should be capable of generating similar levels of disorder, and so achieve technologically-attractive performance in MgB2 by economically-viable routes.Comment: 5 pages, 4 figures, to be published in Nature (in press

    Multi-centre reproducibility of diffusion MRI parameters for clinical sequences in the brain.

    Get PDF
    The purpose of this work was to assess the reproducibility of diffusion imaging, and in particular the apparent diffusion coefficient (ADC), intra-voxel incoherent motion (IVIM) parameters and diffusion tensor imaging (DTI) parameters, across multiple centres using clinically available protocols with limited harmonization between sequences. An ice-water phantom and nine healthy volunteers were scanned across fives centres on eight scanners (four Siemens 1.5T, four Philips 3T). The mean ADC, IVIM parameters (diffusion coefficient D and perfusion fraction f) and DTI parameters (mean diffusivity MD and fractional anisotropy FA), were measured in grey matter, white matter and specific brain sub-regions. A mixed effect model was used to measure the intra- and inter-scanner coefficient of variation (CV) for each of the five parameters. ADC, D, MD and FA had a good intra- and inter-scanner reproducibility in both grey and white matter, with a CV ranging between 1% and 7.4%; mean 2.6%. Other brain regions also showed high levels of reproducibility except for small structures such as the choroid plexus. The IVIM parameter f had a higher intra-scanner CV of 8.4% and inter-scanner CV of 24.8%. No major difference in the inter-scanner CV for ADC, D, MD and FA was observed when analysing the 1.5T and 3T scanners separately. ADC, D, MD and FA all showed good intra-scanner reproducibility, with the inter-scanner reproducibility being comparable or faring slightly worse, suggesting that using data from multiple scanners does not have an adverse effect compared with using data from the same scanner. The IVIM parameter f had a poorer inter-scanner CV when scanners of different field strengths were combined, and the parameter was also affected by the scan acquisition resolution. This study shows that the majority of diffusion MRI derived parameters are robust across 1.5T and 3T scanners and suitable for use in multi-centre clinical studies and trials
    corecore