17 research outputs found

    Evaluation of a ophthalmology learning support for handheld computer for medical students

    Get PDF
    OBJECTIVE: In the last decade the handheld computers have been popularized among health professionals, on the USA, for instance, among 60-70% of medical students already use them. Make clinical information available on these devices can aid teaching medical practices, however, the way they are structured may influence students' satisfaction and learning. The purpose of this paper is to present MDFluxo evaluation, a program developed in handheld computers to aid ophthalmology teaching. METHODS: The program was developed with structured flowcharts extracted from The Ophthalmology Guide book. The assessment was placed comparing 20 medical under-graduating students' performance solving clinical cases aided by the program, a book, or no material. RESULTS: The results shown that the performance of students in the evaluation with book was equivalent to MDFluxo in etiology (p <0.01) and conduct (p <0.05) on clinical cases solving and better performance than without the use any material. CONCLUSION: On MDFluxo user satisfaction evaluation 82.5% of students approved it's use on clinical case solving.OBJETIVO: Na última década os computadores de mão se popularizaram entre profissionais da saúde. Nos EUA, por exemplo, cerca de 60-70% dos estudantes de medicina já os utilizam. A disponibilização de informação clínica nestes dispositivos pode auxiliar no ensino de práticas médicas, no entanto, a maneira como são estruturadas pode influenciar na satisfação e no aprendizado dos alunos. Portanto, este artigo objetiva apresentar os resultados da avaliação do MDFluxo: um programa para auxílio ao ensino de oftalmologia em computadores de mão. MÉTODOS: O programa foi desenvolvido com fluxogramas estruturados, extraídos do Guia de Oftalmologia da Universidade Federal de São Paulo (UNIFESP). A avaliação foi realizada, comparando o desempenho de 20 estudantes de medicina na solução de casos clínicos, utilizando o programa, o livro ou nenhum material. RESULTADOS: Os resultados mostram que o desempenho dos estudantes na avaliação com o livro foi equivalente ao MDFluxo nas questões sobre etiologia (p<0,01) e conduta (p<0,05) na solução dos casos clínicos, desempenho melhor do que sem a utilização de nenhum material. CONCLUSÃO: Na avaliação de satisfação com o uso do programa 82,5% dos estudantes aprovou sua utilização na solução de casos clínicos.Universidade Federal de São Paulo (UNIFESP) Departamento de InformáticaUniversidade Federal de São Paulo (UNIFESP) , Departamento de OftalmologiaUniversidade Federal de São Paulo (UNIFESP) Departamento de OftalmologiaUniversidade Federal de São Paulo (UNIFESP) Departamento de Informática em SaúdeUNIFESP, Depto. de InformáticaUNIFESP, , Depto. de OftalmologiaUNIFESP, Depto. de OftalmologiaUNIFESP, Depto. de Informática em SaúdeSciEL

    Utilidade da estesiometria corneal na triagem da retinopatia diabética

    Get PDF
    OBJETIVO: Avaliar a utilidade da estesiometria corneal na triagem da retinopatia diabética. MÉTODOS: Foi realizado um estudo transversal (N=575) em um programa de triagem de retinopatia diabética da Cidade de São Paulo, SP. A sensibilidade corneal foi aferida utilizando-se o estesiômetro de Cochet-Bonnet. A avaliação da retinopatia diabética foi obtida por meio da fundoscopia indireta. A validade do uso da estesiometria corneal na identificação de pacientes com retinopatia diabética foi avaliada por meio de curvas de sensibilidade e especificidade (Receiver Operating Characteristics (ROC) curve). RESULTADOS: A análise da sensibilidade e da especificidade da estesiometria corneal na detecção dos diferentes graus de retinopatia, utilizando-se diferentes pontos de corte, mostrou resultados inferiores a 80%. O melhor resultado obtido ocorreu na identificação de pacientes com retinopatia diabética proliferativa, mostrando sensibilidade de 72,2% e especificidade de 57,4%. CONCLUSÕES: Na série analisada, a estesiometria corneal não se mostrou um bom indicador da presença da retinopatia diabética.OBJECTIVE: To assess the usefulness of corneal esthesiometry for screening diabetic retinopathy. METHODS: A cross-sectional study was carried out comprising 575 patients attending a diabetic retinopathy-screening program in the city of São Paulo. Corneal esthesiometry was assessed with the Cochet-Bonnet esthesiometer. The presence of diabetic retinopathy was detected with indirect fundoscopy. The validity of corneal esthesiometry in identifying diabetic retinopathy was evaluated by the Receiver Operating Characteristic (ROC) curve. RESULTS: Sensitivity and specificity analyses of the corneal esthesiometry for detecting the stages of diabetic retinopathy using different cut-offs showed values less than 80%. The best indices (72.2% sensitivity and 57.4% specificity) were obtained for the identification of patients with proliferative diabetic retinopathy. CONCLUSIONS: In the study series, corneal esthesiometry was not a good indicator of diabetic retinopathy

    Utilidade da estesiometria corneal na triagem da retinopatia diabética

    Get PDF
    OBJECTIVE: To assess the usefulness of corneal esthesiometry for screening diabetic retinopathy. METHODS: A cross-sectional study was carried out comprising 575 patients attending a diabetic retinopathy-screening program in the city of São Paulo. Corneal esthesiometry was assessed with the Cochet-Bonnet esthesiometer. The presence of diabetic retinopathy was detected with indirect fundoscopy. The validity of corneal esthesiometry in identifying diabetic retinopathy was evaluated by the Receiver Operating Characteristic (ROC) curve. RESULTS: Sensitivity and specificity analyses of the corneal esthesiometry for detecting the stages of diabetic retinopathy using different cut-offs showed values less than 80%. The best indices (72.2% sensitivity and 57.4% specificity) were obtained for the identification of patients with proliferative diabetic retinopathy. CONCLUSIONS: In the study series, corneal esthesiometry was not a good indicator of diabetic retinopathy.OBJETIVO: Avaliar a utilidade da estesiometria corneal na triagem da retinopatia diabética. MÉTODOS: Foi realizado um estudo transversal (N=575) em um programa de triagem de retinopatia diabética da Cidade de São Paulo, SP. A sensibilidade corneal foi aferida utilizando-se o estesiômetro de Cochet-Bonnet. A avaliação da retinopatia diabética foi obtida por meio da fundoscopia indireta. A validade do uso da estesiometria corneal na identificação de pacientes com retinopatia diabética foi avaliada por meio de curvas de sensibilidade e especificidade (Receiver Operating Characteristics (ROC) curve). RESULTADOS: A análise da sensibilidade e da especificidade da estesiometria corneal na detecção dos diferentes graus de retinopatia, utilizando-se diferentes pontos de corte, mostrou resultados inferiores a 80%. O melhor resultado obtido ocorreu na identificação de pacientes com retinopatia diabética proliferativa, mostrando sensibilidade de 72,2% e especificidade de 57,4%. CONCLUSÕES: Na série analisada, a estesiometria corneal não se mostrou um bom indicador da presença da retinopatia diabética.Universidade Federal de São Paulo (UNIFESP) Departamento de OftalmologiaUNIFESP, Depto. de OftalmologiaSciEL

    Economical impact of ocular ultrasound examination in patients with dense cataract aided by public health system

    No full text
    Objetivo: O presente estudo objetiva avaliar o exame de ultra-sonografia ocular em pacientes com catarata densa, como instrumento para evitar inefiCiência de alocacao de recursos economicos em cirurgias com prognostico reservado. Metodo : Avaliacao retrospectiva do laudo de ultra-sonografia ocular de 1018 olhos de 865 pacientes, submetidos a avaliacao pre-cirurgica de catarata. A tabela de procedimentos APACIAINH - SUS 2001-2002 foi utilizada para a coleta dos valores dos procedimentos de ultra-sonografia ocular, cirurgia de catarata extracapsular, facoemulsificacao e vitrectomia via pars plana(WPP). Resultados : O descolamento de retina foi mais frequente em olhos de pacientes com idade entre 18-50 anos (15,9°1o do total de descolamentos de retina) do que em pacientes com mais de 50 anos (4 por cento). O valor total do pagamento efetuado pelo SUS pelos 1018 exames de ultra-sonografia, realizados na amostra estudada, foi de R12.562,12.OsvaloresdirecionadosaopagamentodecirurgiasdecatarataemolhoscomdescolamentoderetinaalcancariamR 12.562,12. Os valores direcionados ao pagamento de cirurgias de catarata em olhos com descolamento de retina alcancariam R 28.352,00 (extracapsular) e R41.152,00(facoemulsificacao).Evidenciase,atravesdesteestudo,queovalordeR 41.152,00 (facoemulsificacao). Evidencia-se, atraves deste estudo, que o valor de R 12.562,12 relativo ao pagamento do total de exames de US realizados em 1018 olhos e bastante inferior (30,5 por cento no caso de FACO e 44,3 por cento no caso de FEC) aos valores anteriormente mencionados para a realizacao da cirurgia de catarata em olhos com descolamento de retina e prognostico reservado. Conclusao : A ultra-sonografia antecedendo a cirurgia de catarata densa e altamente recomendavel para analisar o prognostico e orientar quanto a melhor solucao cirurgica para cada caso, economizando recursos e preservando a boa pratica medicaBV UNIFESP: Teses e dissertaçõe
    corecore