7,123 research outputs found

    Amyloid-like peptide nanofiber templated titania nanostructures as dye sensitized solar cell anodic materials

    Get PDF
    Cataloged from PDF version of article.One-dimensional titania nanostructures can serve as a support for light absorbing molecules and result in an improvement in the short circuit current (Jsc) and open circuit voltage (Voc) as a nanostructured and high-surface-area material in dye-sensitized solar cells. Here, self-assembled amyloid-like peptide nanofibers were exploited as an organic template for the growth of one-dimensional titania nanostructures. Nanostructured titania layers were utilized as anodic materials in dye sensitized solar cells (DSSCs). The photovoltaic performance of the DSSC devices was assessed and an enhancement in the overall cell performance compared to unstructured titania was observed. © 2013 The Royal Society of Chemistry

    Performance of a diagnostic algorithm for fibrotic hypersensitivity pneumonitis. A case-control study.

    Get PDF
    The differential diagnosis fibrotic hypersensitivity pneumonitis (HP) versus idiopathic pulmonary fibrosis (IPF) is important but challenging. Recent diagnostic guidelines for HP emphasize including multidisciplinary discussion (MDD) in the diagnostic process, however MDD is not comprehensively available. We aimed to establish the diagnostic accuracy and prognostic validity of a previously proposed HP diagnostic algorithm that foregoes MDD. We tested the algorithm in patients with an MDD diagnosis of fibrotic HP or IPF (case control study) and determined diagnostic test performances for diagnostic confidences of ≄ 90% and ≄ 70%. Prognostic validity was established using Cox proportional hazards models. Thirty-one patients with fibrotic HP and 50 IPF patients were included. The algorithm-derived ≄ 90% confidence level for HP had high specificity (0.94, 95% confidence interval [CI] 0.83-0.99), but low sensitivity (0.35 [95%CI 0.19-0.55], J-index 0.29). Test performance was improved for the ≄ 70% confidence level (J-index 0.64) with a specificity of 0.90 (95%CI 0.78-0.97), and a sensitivity of 0.74 (95%CI 0.55-0.88). MDD fibrotic HP diagnosis was strongly associated with lower risk of death (adjusted hazard ratio [HR] 0.10 [0.01-0.92], p = 0.04), whereas the algorithm-derived ≄ 70% and ≄ 90% confidence diagnoses were not significantly associated with survival (adjusted HR 0.37 [0.07-1.80], p = 0.22, and adjusted HR 0.41 [0.05-3.25], p = 0.39, respectively). The algorithm-derived ≄ 70% diagnostic confidence had satisfactory test performance for MDD-HP diagnosis, with insufficient sensitivity for ≄ 90% confidence. The lowest risk of death in the MDD-derived HP diagnosis validates the reference standard and suggests that a diagnostic algorithm not including MDD, might not replace the latter

    Double Spin Asymmetries A_NN and A_SS at sqrt{s}=200 GeV in Polarized Proton-Proton Elastic Scattering at RHIC

    Get PDF
    We present the first measurements of the double spin asymmetries A_NN and A_SS at sqrt{s}=200 GeV, obtained by the pp2pp experiment using polarized proton beams at the Relativistic Heavy Ion Collider (RHIC). The data were collected in the four momentum transfer t range 0.01<|t|<0.03 (GeV/c)^2. The measured asymmetries, which are consistent with zero, allow us to estimate upper limits on the double helicity-flip amplitudes phi_2 and phi_4 at small t as well as on the difference Delta(sigma_T) between the total cross sections for transversely polarized protons with antiparallel or parallel spin orientations.Comment: 13 pages with 3 figures. Final version accepted by Phys. Lett.

    Measurement of Target and Double-Spin Asymmetries for the ep → eπ+(n) Reaction in the Nucleon Resonance Region at Low QÂČ

    Get PDF
    We report measurements of target- and double-spin asymmetries for the exclusive channel →e→p → eπ+(n) in the nucleon resonance region at Jefferson Lab using the CEBAF Large Acceptance Spectrometer (CLAS). These asymmetries were extracted from data obtained using a longitudinally polarized NH3 target and a longitudinally polarized electron beam with energies 1.1, 1.3, 2.0, 2.3, and 3.0 GeV. The new results are consistent with previous CLAS publications but are extended to a low Q2 range from 0.0065 to 0.35(GeV/c)2. The Q2 access was made possible by a custom-built Cherenkov detector that allowed the detection of electrons for scattering angles as low as 6°. These results are compared with the unitary isobar models JANR and MAID, the partial-wave analysis prediction from SAID, and the dynamic model DMT. In many kinematic regions our results, in particular results on the target asymmetry, help to constrain the polarization-dependent components of these models

    G0^0 Electronics and Data Acquisition (Forward-Angle Measurements)

    Get PDF
    The G0^0 parity-violation experiment at Jefferson Lab (Newport News, VA) is designed to determine the contribution of strange/anti-strange quark pairs to the intrinsic properties of the proton. In the forward-angle part of the experiment, the asymmetry in the cross section was measured for e⃗p\vec{e}p elastic scattering by counting the recoil protons corresponding to the two beam-helicity states. Due to the high accuracy required on the asymmetry, the G0^0 experiment was based on a custom experimental setup with its own associated electronics and data acquisition (DAQ) system. Highly specialized time-encoding electronics provided time-of-flight spectra for each detector for each helicity state. More conventional electronics was used for monitoring (mainly FastBus). The time-encoding electronics and the DAQ system have been designed to handle events at a mean rate of 2 MHz per detector with low deadtime and to minimize helicity-correlated systematic errors. In this paper, we outline the general architecture and the main features of the electronics and the DAQ system dedicated to G0^0 forward-angle measurements.Comment: 35 pages. 17 figures. This article is to be submitted to NIM section A. It has been written with Latex using \documentclass{elsart}. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment In Press (2007

    Assessment of Subclinical Psychotic Symptoms in Patients with Rheumatoid Arthritis and Spondyloarthritis

    Get PDF
    Inflammatory and autoimmune processes have been associated with the onset of depressive and psychotic symptoms. Rheumatoid arthritis (RA) and spondyloarthritis (SpA) are rheumatic diseases with an inflammatory etiology. A high prevalence of depressive and anxiety-related comorbidity has been reported for both diseases, with no evidence of a greater prevalence of psychosis. The objective of the present study was to evaluate for the first time subclinical psychotic symptoms in patients with RA and SpA. This is a cross-sectional, single-center study including RA and SpA patients, as well as healthy controls. Abnormal psychotic experiences (positive, negative, and depressive symptoms) were evaluated using the Community Assessment of Psychic Experiences (CAPE-42). Functional capacity was evaluated using the Short-Form Health Survey SF-12. We compared the CAPE and SF-12 scores between the three groups. We recruited 385 individuals: 218 with RA, 100 with SpA, and 67 healthy controls. According to the CAPE scale, the frequency of subclinical psychotic symptoms was greater in patients than in healthy controls (RA, 1.90 vs. 1.63, p < 0.001; SpA, 1.88 vs. 1.63, p = 0.001). Distress was also greater in patients than in controls owing to the presence of symptoms. No differences were observed between the three groups for the mental dimension scores in the SF-12 Health Survey (43.75 in RA, 45.54 in SpA, and 43.19 in healthy controls). Our findings point to a greater prevalence of subclinical psychotic symptoms in patients with RA and patients with SpA than in the general population. The results suggest an association between inflammation and depression/subclinical psychotic symptoms

    Cross Sections for the Exclusive Photon Electroproduction on the Proton and Generalized Parton Distributions

    Get PDF
    Unpolarized and beam-polarized fourfold cross sections (d4σ/dQ2dxBdtdϕ) for the ep → e\u27p\u27Îł reaction were measured using the CLAS detector and the 5.75-GeV polarized electron beam of the Jefferson Lab accelerator, for 110 (Q2;xB;t) bins over the widest phase space ever explored in the valence-quark region. Several models of generalized parton distributions (GPDs) describe the data well at most of our kinematics. This increases our confidence that we understand the GPD H, expected to be the dominant contributor to these observables. Through a leading-twist extraction of Compton form factors, these results support the model predictions of a larger nucleon size at lower quark-momentum fraction xB

    Signaling via interleukin-4, receptor alpha chain is required for successful vaccination against schistosomiasis in BALB/c mice

    Get PDF
    Radiation-attenuated (RA) schistosome larvae are potent stimulators of innate immune responses at the skin site of exposure (pinna) that are likely to be important factors in the development of Th1-mediated protective immunity. In addition to causing an influx of neutrophils, macrophages, and dendritic cells (DCs) into the dermis, RA larvae induced a cascade of chemokine and cytokine secretion following in vitro culture of pinna biopsy samples. While macrophage inflammatory protein 1 and interleukin-1 (IL-1) were produced transiently within the first few days, the Th1-promoting cytokines IL-12 and IL-18 were secreted at high levels until at least day 14. Assay of C3H/HeJ mice confirmed that IL-12 secretion was not due to lipopolysaccharide contaminants binding Toll-like receptor 4. Significantly, IL-12 p40 secretion was sustained in pinnae from vaccinated mice but not in those from nonprotected infected mice. In contrast, IL-10 was produced from both vaccinated and infected mice. This cytokine regulates IL-12-associated dermal inflammation, since in vaccinated IL-10/ mice, pinna thickness was greatly increased concurrent with elevated levels of IL-12 p40. A significant number of IL-12 p40 cells were detected as emigrants from in vitro-cultured pinnae, and most were within a population of rare large granular cells that were Ia, consistent with their being antigen-presenting cells. Labeling of IL-12 cells for CD11c, CD205, CD8, CD11b, and F4/80 indicated that the majority were myeloid DCs, although a proportion were CD11c F4/80, suggesting that macrophages were an additional source of IL-12 in the skin

    First Measurement of A_N at sqrt(s)=200 GeV in Polarized Proton-Proton Elastic Scattering at RHIC

    Get PDF
    We report on the first measurement of the single spin analyzing power (A_N) at sqrt(s)=200GeV, obtained by the pp2pp experiment using polarized proton beams at the Relativistic Heavy Ion Collider (RHIC). Data points were measured in the four momentum transfer t range 0.01 < |t| < 0.03 (GeV/c)^2. Our result, averaged over the whole t-interval is about one standard deviation above the calculation, which uses interference between electromagnetic spin-flip amplitude and hadronic non-flip amplitude, the source of A_N. The difference could be explained by an additional contribution of a hadronic spin-flip amplitude to A_N.Comment: 13 pages, 5 figures. New values of polarization errors. Final version submitted to Phys. Lett.
    • 

    corecore