21,492 research outputs found
Bipartite graph partitioning and data clustering
Many data types arising from data mining applications can be modeled as
bipartite graphs, examples include terms and documents in a text corpus,
customers and purchasing items in market basket analysis and reviewers and
movies in a movie recommender system. In this paper, we propose a new data
clustering method based on partitioning the underlying bipartite graph. The
partition is constructed by minimizing a normalized sum of edge weights between
unmatched pairs of vertices of the bipartite graph. We show that an approximate
solution to the minimization problem can be obtained by computing a partial
singular value decomposition (SVD) of the associated edge weight matrix of the
bipartite graph. We point out the connection of our clustering algorithm to
correspondence analysis used in multivariate analysis. We also briefly discuss
the issue of assigning data objects to multiple clusters. In the experimental
results, we apply our clustering algorithm to the problem of document
clustering to illustrate its effectiveness and efficiency.Comment: Proceedings of ACM CIKM 2001, the Tenth International Conference on
Information and Knowledge Management, 200
Fast Monte Carlo Simulation for Patient-specific CT/CBCT Imaging Dose Calculation
Recently, X-ray imaging dose from computed tomography (CT) or cone beam CT
(CBCT) scans has become a serious concern. Patient-specific imaging dose
calculation has been proposed for the purpose of dose management. While Monte
Carlo (MC) dose calculation can be quite accurate for this purpose, it suffers
from low computational efficiency. In response to this problem, we have
successfully developed a MC dose calculation package, gCTD, on GPU architecture
under the NVIDIA CUDA platform for fast and accurate estimation of the x-ray
imaging dose received by a patient during a CT or CBCT scan. Techniques have
been developed particularly for the GPU architecture to achieve high
computational efficiency. Dose calculations using CBCT scanning geometry in a
homogeneous water phantom and a heterogeneous Zubal head phantom have shown
good agreement between gCTD and EGSnrc, indicating the accuracy of our code. In
terms of improved efficiency, it is found that gCTD attains a speed-up of ~400
times in the homogeneous water phantom and ~76.6 times in the Zubal phantom
compared to EGSnrc. As for absolute computation time, imaging dose calculation
for the Zubal phantom can be accomplished in ~17 sec with the average relative
standard deviation of 0.4%. Though our gCTD code has been developed and tested
in the context of CBCT scans, with simple modification of geometry it can be
used for assessing imaging dose in CT scans as well.Comment: 18 pages, 7 figures, and 1 tabl
Relativistic description of J/\psi dissociation in hot matter
The mass spectra and binding radii of heavy quark bound states are studied on
the basis of the reduced Bethe-Salpeter equation. The critical values of
screening masses for and bound states at a finite
temperature are obtained and compared with the previous results given by
non-relativistic models.Comment: 13 latex pages, 2 figure
Antioxidantactivity In Vitro And Hepatoprotective Effect Of Phlomis Maximowiczii In Vivo
Background: Anumber of medicinal plants and there compounds played a major role in the treatment of hepatic disorders. They were widely used for the treatment of these disorders, and oxidant stress injury was one of the liver injury mechanisms. The present study evaluated the antioxidant activity and the hepatoprotective effect of each extracts of Phlomis maximowiczii.Materials and Methods: The antioxidant activity was assayed by the methods of ABTS, FRAP and DPPH in vitro. Hepatoprotective effect of P. maximowiczii extracts was examined using carbon tetrachloride-induced acute liver injury in mice.Results: P. maximowiczii n-butanol (PMBU) extract, ABTS (IC50=18.96 μg/mL), DPPH (IC50=25.15 μg/mL), and FRAP (RACT50=2775.6±144.18 μmol/g), showed higher scavenging capacity than that of P. maximowiczii ethyl acetate (PMEA). The n-butanol extract could significantly reduce the level of GPT, GOT and MDA (P<0.05, P<0.001 and P<0.001, respectively) and increase the level of SOD (P<0.001), respectively.Conclusion: The antioxidant activity of n-butanol extract in vitro was related with the level ofMDAand SOD in vivo, and hepatoprotective effect of n-butanol extract also had relationship with its antioxidant activity in vivo.Key words: Phlomis maximowiczii, anti-oxidation, acute liver in jury, carbon tetrachloride
A new class of -d topological superconductor with topological classification
The classification of topological states of matter depends on spatial
dimension and symmetry class. For non-interacting topological insulators and
superconductors the topological classification is obtained systematically and
nontrivial topological insulators are classified by either integer or .
The classification of interacting topological states of matter is much more
complicated and only special cases are understood. In this paper we study a new
class of topological superconductors in dimensions which has
time-reversal symmetry and a spin conservation symmetry. We
demonstrate that the superconductors in this class is classified by
when electron interaction is considered, while the
classification is without interaction.Comment: 5 pages main text and 3 pages appendix. 1 figur
The Properties of H{\alpha} Emission-Line Galaxies at z = 2.24
Using deep narrow-band and -band imaging data obtained with
CFHT/WIRCam, we identify a sample of 56 H emission-line galaxies (ELGs)
at with the 5 depths of and (AB)
over 383 arcmin area in the ECDFS. A detailed analysis is carried out
with existing multi-wavelength data in this field. Three of the 56 H
ELGs are detected in Chandra 4 Ms X-ray observation and two of them are
classified as AGNs. The rest-frame UV and optical morphologies revealed by
HST/ACS and WFC3 deep images show that nearly half of the H ELGs are
either merging systems or with a close companion, indicating that the
merging/interacting processes play a key role in regulating star formation at
cosmic epoch z=2-3; About 14% are too faint to be resolved in the rest-frame UV
morphology due to high dust extinction. We estimate dust extinction from SEDs.
We find that dust extinction is generally correlated with H luminosity
and stellar mass (SM). Our results suggest that H ELGs are
representative of star-forming galaxies (SFGs). Applying extinction correction
for individual objects, we examine the intrinsic H luminosity function
(LF) at , obtaining a best-fit Schechter function characterized by a
faint-end slope of . This is shallower than the typical slope of
in previous works based on constant extinction correction.
We demonstrate that this difference is mainly due to the different extinction
corrections. The proper extinction correction is thus key to recovering the
intrinsic LF as the extinction globally increases with H luminosity.
Moreover, we find that our H LF mirrors the SM function of SFGs at the
same cosmic epoch. This finding indeed reflects the tight correlation between
SFR and SM for the SFGs, i.e., the so-called main sequence.Comment: 15 pages, 12 figures, 2 tables, Received 2013 October 11; accepted
2014 February 13; published 2014 March 18 by Ap
A GPU-based finite-size pencil beam algorithm with 3D-density correction for radiotherapy dose calculation
Targeting at the development of an accurate and efficient dose calculation
engine for online adaptive radiotherapy, we have implemented a finite size
pencil beam (FSPB) algorithm with a 3D-density correction method on GPU. This
new GPU-based dose engine is built on our previously published ultrafast FSPB
computational framework [Gu et al. Phys. Med. Biol. 54 6287-97, 2009].
Dosimetric evaluations against Monte Carlo dose calculations are conducted on
10 IMRT treatment plans (5 head-and-neck cases and 5 lung cases). For all
cases, there is improvement with the 3D-density correction over the
conventional FSPB algorithm and for most cases the improvement is significant.
Regarding the efficiency, because of the appropriate arrangement of memory
access and the usage of GPU intrinsic functions, the dose calculation for an
IMRT plan can be accomplished well within 1 second (except for one case) with
this new GPU-based FSPB algorithm. Compared to the previous GPU-based FSPB
algorithm without 3D-density correction, this new algorithm, though slightly
sacrificing the computational efficiency (~5-15% lower), has significantly
improved the dose calculation accuracy, making it more suitable for online IMRT
replanning
- …