36 research outputs found

    Performance evaluation of fifth-generation ultra-high-resolution SPECT system with two stationary detectors and multi-pinhole imaging

    Get PDF
    Background Small-animal single-photon emission computed tomography (SPECT) systems with multi-pinhole collimation and large stationary detectors have advantages compared to systems with moving small detectors. These systems benefit from less labour-intensive maintenance and quality control as fewer prone parts are moving, higher accuracy for focused scans and maintaining high resolution with increased sensitivity due to focused pinholes on the field of view. This study aims to investigate the performance of a novel ultra-high-resolution scanner with two-detector configuration (U-SPECT5-E) and to compare its image quality to a conventional micro-SPECT system with three stationary detectors (U-SPECT+). Methods The new U-SPECT5-E with two stationary detectors was used for acquiring data with Tc-99m-filled point source, hot-rod and uniformity phantoms to analyse sensitivity, spatial resolution, uniformity and contrast-to-noise ratio (CNR). Three dedicated multi-pinhole mouse collimators with 75 pinholes each and 0.25-, 0.60- and 1.00-mm pinholes for extra ultra-high resolution (XUHR-M), general-purpose (GP-M) and ultra-high sensitivity (UHS-M) imaging were examined. For CNR analysis, four different activity ranges representing low- and high-count settings were investigated for all three collimators. The experiments for the performance assessment were repeated with the same GP-M collimator in the three-detector U-SPECT+ for comparison. Results Peak sensitivity was 237 cps/MBq (XUHR-M), 847 cps/MBq (GP-M), 2054 cps/MBq (UHS-M) for U-SPECT5-E and 1710 cps/MBq (GP-M) for U-SPECT+. In the visually analysed sections of the reconstructed mini Derenzo phantoms, rods as small as 0.35 mm (XUHR-M), 0.50 mm (GP-M) for the two-detector as well as the three-detector SPECT and 0.75 mm (UHS-M) were resolved. Uniformity for maximum resolution recorded 40.7% (XUHR-M), 29.1% (GP-M, U-SPECT5-E), 16.3% (GP-M, U-SPECT+) and 23.0% (UHS-M), respectively. UHS-M reached highest CNR values for low-count images; for rods smaller than 0.45 mm, acceptable CNR was only achieved by XUHR-M. GP-M was superior for imaging rods sized from 0.60 to 1.50 mm for intermediate activity concentrations. U-SPECT5-E and U-SPECT+ both provided comparable CNR. Conclusions While uniformity and sensitivity are negatively affected by the absence of a third detector, the investigated U-SPECT5-E system with two stationary detectors delivers excellent spatial resolution and CNR comparable to the performance of an established three-detector-setup

    Capabilities of multi-pinhole SPECT with two stationary detectors for in vivo rat imaging

    Get PDF
    We aimed to investigate the image quality of the U-SPECT5/CT E-Class a micro single-photon emission computed tomography (SPECT) system with two large stationary detectors for visualization of rat hearts and bones using clinically available Tc-99m-labelled tracers. Sensitivity, spatial resolution, uniformity and contrast-to-noise ratio (CNR) of the small-animal SPECT scanner were investigated in phantom studies using an ultra-high-resolution rat and mouse multi-pinhole collimator (UHR-RM). Point source, hot-rod, and uniform phantoms with Tc-99m-solution were scanned for high-count performance assessment and count levels equal to animal scans, respectively. Reconstruction was performed using the similarity-regulated ordered-subsets expectation maximization (SROSEM) algorithm with Gaussian smoothing. Rats were injected with similar to 100 MBq [Tc-99m]Tc-MIBI or similar to 150 MBq [Tc-99m]Tc-HMDP and received multi-frame micro-SPECT imaging after tracer distribution. Animal scans were reconstructed for three different acquisition times and post-processed with different sized Gaussian filters. Following reconstruction, CNR was calculated and image quality evaluated by three independent readers on a five-point scale from 1="very poor" to 5="very good". Point source sensitivity was 567 cps/MBq and radioactive rods as small as 1.2 mm were resolved with the UHR-RM collimator. Collimator-dependent uniformity was 55.5%. Phantom CNR improved with increasing rod size, filter size and activity concentration. Left ventricle and bone structures were successfully visualized in rat experiments. Image quality was strongly affected by the extent of post-filtering, whereas scan time did not have substantial influence on visual assessment. Good image quality was achieved for resolution range greater than 1.8 mm in bone and 2.8 mm in heart. The recently introduced small animal SPECT system with two stationary detectors and UHR-RM collimator is capable to provide excellent image quality in heart and bone scans in a rat using standardized reconstruction parameters and appropriate post-filtering. However, there are still challenges in achieving maximum system resolution in the sub-millimeter range with in vivo settings under limited injection dose and acquisition time

    Detecting tactical patterns in basketball:Comparison of merge self-organising maps and dynamic controlled neural networks

    No full text
    The soaring amount of data, especially spatial-temporal data, recorded in recent years demands for advanced analysis methods. Neural networks derived from self-organizing maps established themselves as a useful tool to analyse static and temporal data. In this study, we applied the merge self-organising map (MSOM) to spatio-temporal data. To do so, we investigated the ability of MSOM ' s to analyse spatio-temporal data and compared its performance to the common dynamical controlled network (DyCoN) approach to analyse team sport position data. The position data of 10 players were recorded via the Ubisense tracking system during a basketball game. Furthermore, three different pre-selected plays were recorded for classification. Following data preparation, the different nets were trained with the data of the first half. The training success of both networks was evaluated by achieved entropy. The second half of the basketball game was presented to both nets for automatic classification. Both approaches were able to present the trained data extremely well and to detect the pre-selected plays correctly. In conclusion, MSOMs are a useful tool to analyse spatial-temporal data, especially in team sports. By their direct inclusion of different time length of tactical patterns, they open up new opportunities within team sports

    Tablet-based versus presentation-based seminars in radiology: Effects of student digital affinity and teacher charisma on didactic quality

    No full text
    Aims: Tablets are being adopted as teaching medium in medical education more frequently. Here we compared two teaching formats in a radiology seminar using a tablet-based student-centred approach guided by teachers and traditional presentation-based, teacher-centred instruction. The aim was to investigate the effects on academic performance, estimated learning gain, didactic quality, as well as how teacher charisma and student digital affinity influence these elements. Methods: Data from 366 students were collected. Student digital affinity, didactic quality of, and overall satisfaction with the seminars were rated for each teaching format over three semesters, whereby in the last semester, students additionally estimated their learning gain, took a knowledge and image interpretation test, and rated teacher charisma. Results: The tablet-based seminars yielded significantly higher ratings for didactic quality and overall satisfaction. However, the presentation-based seminars proved superior with respect to academic performance as well as estimated learning gain. When employing tablets, teacher charisma correlated with estimated learning gain, and digital affinity affected didactic quality. Additionally, good seminar organization, comprehensible learning objectives, and optimal variation of learning activities were identified as important factors.Conclusion: This study suggests a complex interplay of various factors concerning teachers, students, and didactics that can be assessed and improved to assure the successful curricular implementation of tablets. Of note, tablet integration and thereby active engagement of students with imaging analysis skills does not automatically result in greater declarative knowledge. Nevertheless, understanding the complexities of structuring and delivering tablet-based, teacher-guided instruction is essential to creating meaningful educational experiences

    Dual-energy CT in sacral fragility fractures: defining a cut-off Hounsfield unit value for the presence of traumatic bone marrow edema in patients with osteoporosis

    No full text
    Background Demographic change entails an increasing incidence of fragility fractures. Dual-energy CT (DECT) with virtual non-calcium (VNCa) reconstructions has been introduced as a promising diagnostic method for evaluating bone microarchitecture and marrow simultaneously. This study aims to define the most accurate cut-off value in Hounsfield units (HU) for discriminating the presence and absence of bone marrow edema (BME) in sacral fragility fractures. Methods Forty-six patients (40 women, 6 men; 79.7ā€‰Ā±ā€‰9.2 years) with suspected fragility fractures of the sacrum underwent both DECT (90 kVp / 150 kVp with tin prefiltration) and MRI. Nine regions-of-interest were placed in each sacrum on DECT-VNCa images. The resulting 414 HU measurements were stratified into ā€œedemaā€ (nā€‰=ā€‰80) and ā€œno edemaā€ groups (nā€‰=ā€‰334) based on reference BME detection in T2-weighted MRI sequences. Area under the receiver operating characteristic curve was calculated to determine the desired cut-off value and an associated conspicuity range for edema detection. Results The mean density within the ā€œedemaā€ group of measurements (+ā€‰3.1ā€‰Ā±ā€‰8.3 HU) was substantially higher compared to the ā€œno edemaā€ group (-51.7ā€‰Ā±ā€‰21.8 HU; pā€‰<ā€‰0.010). Analysis in DECT-VNCa images suggested a cut-off value of -12.9 HU that enabled sensitivity and specificity of 100% for BME detection compared to MRI. A range of HU values between -14.0 andā€‰+ā€‰20.0 is considered indicative of BME in the sacrum. Conclusions Quantitative analysis of DECT-VNCa with a cut-off of -12.9 HU allows for excellent diagnostic accuracy in the assessment of sacral fragility fractures with associated BME. A diagnostic ā€œone-stop-shopā€ approach without additional MRI is feasible

    Degradation and bone-contact biocompatibility of two drillable magnesium phosphate bone cements in an in vivo rabbit bone defect model

    No full text
    The use of bone-cement-enforced osteosynthesis is a growing topic in trauma surgery. In this context, drillability is a desirable feature for cements that can improve fracture stability, which most of the available cement systems lack. Therefore, in this study, we evaluated a resorbable and drillable magnesium-phosphate (MgP)-based cement paste considering degradation behavior and biocompatibility in vivo. Two different magnesium-phosphate-based cement (MPC) pastes with different amounts of phytic acid (IP 6) as setting retarder (MPC 22.5 and MPC 25) were implanted in an orthotopic defect model of the lateral femoral condyle of New Zealand white rabbits for 6 weeks. After explantation, their resorption behavior and material characteristics were evaluated by means of X-ray diffraction (XRD), porosimetry measurement, histological staining, peripheral quantitative computed tomography (pQCT), cone-beam computed tomography (CBCT) and biomechanical load-to-failure tests. Both cement pastes displayed comparable results in mechanical strength and resorption kinetics. Bone-contact biocompatibility was excellent without any signs of inflammation. Initial resorption and bone remodeling could be observed. MPC pastes with IP 6 as setting retardant have the potential to be a valuable alternative in distinct fracture patterns. Drillability, promising resorption potential and high mechanical strength confirm their suitability for use in clinical routine
    corecore