    The capacity to store urine and initiate voiding is a valued characteristic of the human urinary bladder. To maintain this feature, it is necessary that the bladder can sense when it is full and when it is time to void. The bladder has a specialized epithelium called urothelium that is believed to be important for its sensory function. It has been suggested that autocrine ATP signalling contributes to this sensory function of the urothelium. There is well‐established evidence that ATP is released via vesicular exocytosis as well as by pannexin hemichannels upon mechanical stimulation. However, there are still many details that need elucidation and therefore there is a need for the development of new tools to further explore this fascinating field. In this work, we use new microphysiological systems to study mechanostimulation at a cellular level: a mechanostimulation microchip and a silicone‐based cell stretcher. Using these tools, we show that ATP is released upon cell stretching and that extracellular ATP contributes to a major part of Ca2+ signalling induced by stretching in T24 cells. These results contribute to the increasing body of evidence for ATP signalling as an important component for the sensory function of urothelial cells. This encourages the development of drugs targeting P2 receptors to relieve suffering from overactive bladder disorder and incontinence

    Analytical Performance Characteristics of the Cepheid GeneXpert Ebola Assay for the Detection of Ebola Virus

    No full text
    <div><p>Background</p><p>The recently developed XpertÂź Ebola Assay is a novel nucleic acid amplification test for simplified detection of Ebola virus (EBOV) in whole blood and buccal swab samples. The assay targets sequences in two EBOV genes, lowering the risk for new variants to escape detection in the test. The objective of this report is to present analytical characteristics of the XpertÂź Ebola Assay on whole blood samples.</p><p>Methods and Findings</p><p>This study evaluated the assay’s analytical sensitivity, analytical specificity, inclusivity and exclusivity performance in whole blood specimens. EBOV RNA, inactivated EBOV, and infectious EBOV were used as targets. The dynamic range of the assay, the inactivation of virus, and specimen stability were also evaluated. The lower limit of detection (LoD) for the assay using inactivated virus was estimated to be 73 copies/mL (95% CI: 51–97 copies/mL). The LoD for infectious virus was estimated to be 1 plaque-forming unit/mL, and for RNA to be 232 copies/mL (95% CI 163–302 copies/mL). The assay correctly identified five different Ebola viruses, Yambuku-Mayinga, Makona-C07, Yambuku-Ecran, Gabon-Ilembe, and Kikwit-956210, and correctly excluded all non-EBOV isolates tested. The conditions used by XpertÂź Ebola for inactivation of infectious virus reduced EBOV titer by ≄6 logs.</p><p>Conclusion</p><p>In summary, we found the XpertÂź Ebola Assay to have high analytical sensitivity and specificity for the detection of EBOV in whole blood. It offers ease of use, fast turnaround time, and remote monitoring. The test has an efficient viral inactivation protocol, fulfills inclusivity and exclusivity criteria, and has specimen stability characteristics consistent with the need for decentralized testing. The simplicity of the assay should enable testing in a wide variety of laboratory settings, including remote laboratories that are not capable of performing highly complex nucleic acid amplification tests, and during outbreaks where time to detection is critical.</p></div
    corecore