353 research outputs found

    Clinical outcome 10 years after attempted percutaneous transluminal coronary angioplasty in 856 patients.

    Get PDF
    Abstract OBJECTIVES: This study reports the 10-year outcome of 856 consecutive patients who underwent attempted coronary angioplasty at the Thoraxcenter during the years 1980 to 1985. BACKGROUND: Coronary balloon angioplasty was first performed in 1977, and this procedure was introduced into clinical practice at the Thoraxcenter in 1980. Although advances have been made, extending our knowledge of the long-term outcome in terms of survival and major cardiac events remains of interest and a valuable guide in the treatment of patients with coronary artery disease. METHODS: Details of survival, cardiac events, symptoms and medication were retrospectively obtained from the Dutch civil registry, medical records or by letter or telephone or from the patient's physician and entered into a dedicated data base. Patient survival curves were constructed, and factors influencing survival and cardiac events were identified. RESULTS: The procedural clinical success rate was 82%. Follow-up information was obtained in 837 patients (97.8%). Six hundred forty-one patients (77%) were alive, of whom 334 (53%) were symptom free, and 254 (40%) were taking no antianginal medication. The overall 5- and 10-year survival rates were 90% (95% confidence interval [CI] 87.6% to 92.4%) and 78% (95% CI 75.0% to 81.0%), respectively, and the respective freedom from significant cardiac events (death, myocardial infarction, coronary artery bypass surgery and repeat angioplasty) was 57% (95% CI 53.4% to 60.6%) and 36% (95% CI 32.4% to 39.6%). Factors that were found to adversely influence 10-year survival were age > or = 60 years (> or = 60 years [67%], 50 to 59 years [82%], or = 50% [80%]) and a history of previous myocardial infarction (previous myocardial infarction [72%], no previous infarction [83%]). These factors were also found to be independent predictors of death during the follow-up period by a multivariate stepwise logistic regression analysis. Other factors tested, with no influence on survival, were gender, procedural success and stability of angina at the time of intervention. CONCLUSIONS: The long-term prognosis of patients after coronary angioplasty is good, particularly in those <60 years old with single-vessel disease and normal left ventricular function. The majority of patients are likely to experience a further cardiac event in the 10 years after their first angioplasty procedure

    Quantitative angiographic comparison of elastic recoil after coronary excimer laser-assisted balloon angioplasty and balloon angioplasty alone.

    Get PDF
    AbstractObjectives. Coronary lumen changes during and after excimer laser-assisted balloon angioplasty were measured by quantitative coronary angiography, and the results were compared with the effects of balloon angioplasty alone.Background. Reduction of atherosclerotic tissue mass by laser ablation in the treatment of coronary artery disease may be more effective in enlarging the lumen than balloon angioplasty alone.Methods. A series of 57 consecutive coronary lesions successfully treated by xenon chloride excimer laser-assisted balloon angioplasty were individually matched with 57 coronary artery lesions successfully treated by balloon angioplasty alone. The following variables were measured by quantitative coronary analysis: 1) ablation by laser, 2) stretch by balloon dilation, 3) elastic recoil, and 4) acute gain.Results. Matching by stenosis location, reference diameter and minimal lumen diameter resulted in two comparable groups of 57 lesions with identical baseline stenosis characteristics. Minimal lumen diameter before excimer laser-assisted balloon angioplasty and balloon angioplasty alone were (mean ± SD) 0.73 ± 0.44 and 0.74 ± 0.43 mm, respectively. Laser ablation significantly improved minimal lumen diameter by 0.56 ± 0.44 mm before adjunctive balloon dilation. In both treatment groups, similar-sized balloon catheters (2.59 ± 0.35 and 2.56 ± 0.40 mm, respectively) were used. After laser-assisted balloon angioplasty, elastic recoil was 0.84 ± 0.30 mm (32% of balloon size), which was identical to that after balloon angioplasty alone, namely, 0.82 ± 0.32 mm (32%). Consequently, both interventions resulted in similar acute gains of 1.02 ± 0.52 and 1.00 ± 0.56 mm, respectively. Minimal lumen diameter after intervention was equal in both groups: 1.75 ± 0.35 and 1.75 ± 0.34 mm, respectively. The statistical power of this study in which a 25% difference in elastic recoil (0.2 mm) between groups was considered clinically important was 95%.Conclusions. In matched groups of successfully treated coronary lesions, xenon chloride excimer laser ablation did not reduce immediate elastic recoil after adjunctive balloon dilation or improve the final angiographic outcome compared with balloon angioplasty alone using similar-sized balloon catheters
    corecore