17,237 research outputs found

    Self-reconfiguring solar cell system

    Get PDF
    A self-reconfiguring solar cell array is disclosed wherein some of the cells are switched so that they can be either in series or in shunt within the array. This feature of series or parallel switching of cells allows the array to match the load to achieve maximum power transfer. Automatic control is used to determine the conditions for maximum power operation and to switch the array into the appropriate configuration necessary to transfer maximum power to the load

    Closed Loop solar array-ion thruster system with power control circuitry

    Get PDF
    A power control circuit connected between a solar array and an ion thruster receives voltage and current signals from the solar array. The control circuit multiplies the voltage and current signals together to produce a power signal which is differentiated with respect to time. The differentiator output is detected by a zero crossing detector and, after suitable shaping, the detector output is phase compared with a clock in a phase demodulator. An integrator receives no output from the phase demodulator when the operating point is at the maximum power but is driven toward the maximum power point for non-optimum operation. A ramp generator provides minor variations in the beam current reference signal produced by the integrator in order to obtain the first derivative of power

    Simplified power supplies for ion thrusters

    Get PDF
    The initial development and demonstration of power supplies with an order of magnitude reduction in parts count, leading to increased reliability at lower weight, while still maintaining thrust system performance are discussed. Two new self-regulating keeper power supply circuits were developed and tested. One supply comprises 14 parts and uses an input voltage range of 18 to 36 volts, the other operates from 200 to 400 volts and requires 22 components. A technique for controlling heater power is also demonstrated

    Simplified dc to dc converter

    Get PDF
    A dc to dc converter which can start with a shorted output and which regulates output voltage and current is described. Voltage controlled switches directed current through the primary of a transformer the secondary of which includes virtual reactance. The switching frequency of the switches is appropriately varied to increase the voltage drop across the virtual reactance in the secondary winding to which there is connected a low impedance load. A starting circuit suitable for voltage switching devices is provided

    New energy storage concept uses tapes

    Get PDF
    Energy storage system uses movable permeable tapes with cathode and electrolyte material that is drawn across an anode to produce electric power. The system features long shelf life, high efficiency, and flexible operation

    Simplification of power electronics for ion thruster neutralizers

    Get PDF
    A need exists for less complex and lower cost ion thruster systems. Design approaches and the demonstration of neutralizer power electronics for relaxed neutralizer keeper, tip heater, and vaporizer requirements are discussed. The neutralizer circuitry is operated from a 200 to 400 V bus and demonstrates an order of magnitude reduction in parts count. Furthermore, a new technique is described for regulating tip heater power and automatically switching over to provide keeper power with only four additional components. A new design to control the flow rate of the neutralizer with one integrated circuit is also presented

    Pulse ignition characterization of mercury ion thruster hollow cathode using an improved pulse ignitor

    Get PDF
    An investigation of the high voltage pulse ignition characteristics of the 8 cm mercury ion thruster neutralizer cathode identified a low rate of voltage rise and long pulse duration as desirable factors for reliable cathode starting. Cathode starting breakdown voltages were measured over a range of mercury flow rates and tip heater powers for pulses with five different rates of voltage rise. Breakdown voltage requirements for the fastest rising pulse (2.5 to 3.0 kV/micro sec) were substantially higher (2 kV or more) than for the slowest rising pulse (0.3 to 0.5 kV/micro sec) for the same starting conditions. Also described is an improved, low impedance pulse ignitor circuit which reduces power losses and eliminates problems with control and packaging associated with earlier designs

    One Thing After Another: Why the Passage of Time Is Not an Illusion

    Get PDF
    Does time seem to pass, even though it doesn’t, really? Many philosophers think the answer is ‘Yes’—at least when ‘time’s passing’ is understood in a particular way. They take time’s passing to be a process by which each time in turn acquires a special status, such as the status of being the only time that exists, or being the only time that is present. This chapter suggests that, on the contrary, all we perceive is temporal succession, one thing after another, a notion to which modern physics is not inhospitable. The contents of perception are best described in terms of ‘before’ and ‘after’, rather than ‘past’, ‘present, and ‘future’

    Reduced CD40L expression on ex vivo activated CD4+T-lymphocytes from patients with excellent renal allograft function measured with a rapid whole blood flow cytometry procedure

    Get PDF
    Background: The CD40-CD40L (CD154) costimulatory pathway plays a critical role in the pathogenesis of kidney allograft rejection. In renal transplant biopsies, CD4+ CD40L+ graft-infiltrating cells were detected during chronic rejection in contrast to acute rejection episodes. Using a rapid noninvasive FACS procedure, we were able to demonstrate CD40L upregulation in peripheral blood of patients with chronic renal allograft dysfunction. Materials and Methods: Whole blood from recipients of renal allografts was stimulated with PMA and ion-omycin and measured by flow cytometry. Patients were assigned to three groups based on transplant function. Group 1: 26 patients with excellent renal transplant function; group 2: 28 patients with impaired transplant function; group 3: 14 patients with chronic allograft dysfunction and group 4: 8 healthy controls. Results: The median percentage +/-SEM of CD4+/ CD40L+ cells stimulated ex vivo at 10 ng/ml PMA was as follows: group 1: 28.3 +/- 4.1%; group 2: 18.4 +/- 2.4%; group 3: 50.1 +/- 5.0% and group 4: 40.4 +/- 3.4%. Subdivisions of groups 2 and 3 resulted in different CD40L expression patterns. Patients with increased serum creatinine since the initial phase after transplantation ( groups 2a and 3a) revealed a higher percentage of CD4+ CD40L+ cells than patients showing a gradual increase over time ( groups 2b and 3b). Consequently, patients of group 3a exhibited a significantly reduced transplant function compared with those of group 3b. Conclusion: After PMA + ionomycin stimulation, patients with excellent kidney graft function displayed significantly reduced expression of CD40L surface molecules on CD4+ cells early after transplantation. Those with a chronic dysfunction of the renal graft showed significantly more CD4+ cells expressing CD40L compared to the other transplanted groups. These results demonstrate that the percentage of CD4+ CD40L+ cells stimulated ex vivo in peripheral blood may be a valuable marker for chronic allograft nephropathy. Copyright (C) 2004 S. Karger AG, Basel

    Power electronics for a 1-kilowatt arc jet thruster

    Get PDF
    After more than two decades, new space mission requirements have revived interest in arcjet systems. The preliminary development and demonstration of new, high efficiency, power electronic concepts for start up and steady state control of dc arcjets is reported. The design comprises a pulse width modulated power converter which is closed loop configured to give fast current control. An inductor, in series with the arcjet, serves the dual role of providing instantaneous current control, as well as a high voltage arc ignition pulse. Benchmark efficiency, transient response, regulation, and ripple data are presented. Tests with arcjets demonstrate that the power electronics breadboard can start thrusters consistently with no apparent damage and transfer reliably to the nondestructive high voltage arc mode in less than a second
    corecore