21 research outputs found

    A Geologically Based Indoor-Radon Potential Map of Kentucky

    Get PDF
    We combined 71,930 short-term (median duration 4 days) home radon test results with 1:24,000-scale bedrock geologic map coverage of Kentucky to produce a statewide geologically based indoor-radon potential map. The test results were positively skewed with a mean of 266 Bq/m3, median of 122 Bq/m3, and 75th percentile of 289 Bq/m3. We identified 106 formations with ≄10 test results. Analysis of results from 20 predominantly monolithologic formations showed indoor-radon concentrations to be positively skewed on a formation-by-formation basis, with a proportional relationship between sample means and standard deviations. Limestone (median 170 Bq/m3) and dolostone (median 130 Bq/m3) tended to have higher indoor-radon concentrations than siltstones and sandstones (median 67 Bq/m3) or unlithified surficial deposits (median 63 Bq/m3). Individual shales had median values ranging from 67 to 189 Bq/m3; the median value for all shale values was 85 Bq/m3. Percentages of values falling above the U.S. Environmental Protection Agency (EPA) action level of 148 Bq/m3 were sandstone and siltstone: 24%, unlithified clastic: 21%, dolostone: 46%, limestone: 55%, and shale: 34%. Mississippian limestones, Ordovician limestones, and Devonian black shales had the highest indoor-radon potential values in Kentucky. Indoor-radon test mean values for the selected formations were also weakly, but statistically significantly, correlated with mean aeroradiometric uranium concentrations. To produce a map useful to nonspecialists, we classified each of the 106 formations into five radon-geologic classes on the basis of their 75th percentile radon concentrations. The statewide map is freely available through an interactive internet map service

    Lysophosphatidic acid and sphingosine-1-phosphate promote morphogenesis and block invasion of prostate cancer cells in three-dimensional organotypic models

    Get PDF
    Normal prostate and some malignant prostate cancer (PrCa) cell lines undergo acinar differentiation and form spheroids in three-dimensional (3-D) organotypic culture. Acini formed by PC-3 and PC-3M, less pronounced also in other PrCa cell lines, spontaneously undergo an invasive switch, leading to the disintegration of epithelial structures and the basal lamina, and formation of invadopodia. This demonstrates the highly dynamic nature of epithelial plasticity, balancing epithelial-to-mesenchymal transition against metastable acinar differentiation. This study assessed the role of lipid metabolites on epithelial maturation. PC-3 cells completely failed to form acinar structures in delipidated serum. Adding back lysophosphatidic acid (LPA) and sphingosine-1-phosphate (S1P) rescued acinar morphogenesis and repressed invasion effectively. Blocking LPA receptor 1 (LPAR1) functions by siRNA (small interference RNA) or the specific LPAR1 inhibitor Ki16425 promoted invasion, while silencing of other G-protein-coupled receptors responsive to LPA or S1P mainly caused growth arrest or had no effects. The G-proteins Gα12/13 and Gαi were identified as key mediators of LPA signalling via stimulation of RhoA and Rho kinases ROCK1 and 2, activating Rac1, while inhibition of adenylate cyclase and accumulation of cAMP may be secondary. Interfering with these pathways specifically impeded epithelial polarization in transformed cells. In contrast, blocking the same pathways in non-transformed, normal cells promoted differentiation. We conclude that LPA and LPAR1 effectively promote epithelial maturation and block invasion of PrCa cells in 3-D culture. The analysis of clinical transcriptome data confirmed reduced expression of LPAR1 in a subset of PrCa's. Our study demonstrates a metastasis-suppressor function for LPAR1 and Gα12/13 signalling, regulating cell motility and invasion versus epithelial maturation

    Health implications of radon distribution in living rooms and bedrooms in U.K. dwellings – a case study in Northamptonshire

    No full text
    Environmental radon exposure of residents of domestic premises in the United Kingdom (UK) and elsewhere in Europe is estimated on the basis of the measured radon concentrations in, and the relative occupancies of, the principal living room and bedroom. While studies on radon concentration variability in the individual units in apartment blocks in various countries have been described, little data has been reported on variability in two-storey single-family dwellings, and the majority of extant studies consolidate living room and bedroom data early in the analysis. To investigate this further, detailed analysis was made of radon concentration data from a set of thirty-four homes situated in areas of Northamptonshire known to exhibit high radon levels. All homes were of typical UK construction of brick/block/stone walls under a pitched tile/slate roof. Approximately 50% of the sample were detached houses, the remainder being semi-detached (duplex) or terraced (row-house). Around 25% of the sample possessed cellars, while 12% were single-storey dwellings (bungalows), reflecting the typical incidence of this type of dwelling in England. In the two-storey homes, all monitored bedrooms were on the upper floor. Distribution of the ratios of bedroom/living room radon concentrations (BR/LR ratio) in individual properties was left-skewed (mean 0.67, median 0.73, range 0.05–1.05) with a tail extending to just above 1.0. The mean is consistent with the outcome of earlier extensive studies in England, while the variability depends principally on the characteristics of the property, and not on seasonal factors. In a small set of homes, the BR/LR ratio was anomalously low, (mean 0.3). BR/LR ratios in single-storey homes clustered around a value of 1.0, indicating that house design, rather than lifestyle, is the dominant factor in determining bedroom radon concentrations. Homes with higher mean annual radon concentrations showed lower BR/LR ratios, supporting our proposal that, in some homes, radon emanation from building materials may comprise a significant component of the overall radon level

    Radon remediation of a two-storey UK dwelling by active sub-slab depressurisation: effects and health implications of radon concentration distributions

    No full text
    Radon concentration levels in a two-storey detached single-family dwelling in Northamptonshire, UK, were monitored continuously throughout a 5-week period during which active sub-slab depressurisation remediation measures were installed. Remediation of the property was accomplished successfully, with both the mean radon levels and the diurnal variability greatly reduced both upstairs and downstairs. Following remediation, upstairs and downstairs radon concentrations were 33% and 18% of their pre-remediation values respectively: the mean downstairs radon concentration was lower than that upstairs, with pre- and post-remediation values of the upstairs/downstairs concentration ratio, RU/D, of 0.81 and 1.51 respectively. Cross-correlation between upstairs and downstairs radon concentration time-series indicates a time-lag of the order of 1 h or less, suggesting that diffusion of soil-derived radon from downstairs to upstairs either occurs within that time frame or forms a relatively insignificant contribution to the upstairs radon level. Cross-correlation between radon concentration time-series and the corresponding time-series for local atmospheric parameters demonstrated correlation between radon concentrations and internal/external pressure difference prior to remediation; this correlation disappears following remediation. Overall, these observations provide further evidence that radon concentration levels within a dwelling are not necessarily wholly determined by the effects of soil–gas advection, and further support the suggestion that, depending on the precise content of the building materials, upstairs radon levels, in particular, may be dominated by radon exhalation from the walls of the dwelling, especially in areas of low soil–gas rado

    A detailed evaluation of the individual health benefits arising in a domestic property following radon remediation – a case-study in Northamptonshire, U.K.

    No full text
    Radon gas occurs naturally in the environment with variable distribution, concentrating sufficiently in the built environment in some areas to pose a public health risk. Radon levels can be successfully reduced in affected buildings, and large-scale remediation programmes have been justified in terms of accrued costs and benefits. We present results from a house where radon levels in the main living-room and master bedroom were monitored on an hourly basis over extended periods before and after radon remediation by sub-slab depressurisation. These results were combined with results from a recent occupancy survey to estimate the health impact on occupants spending varying times in the home. Prior to remediation, mean hourly radon exposure is moderately linearly correlated (R2 = 0.66–0.78) with time spent in the house. Following remediation, correlation is significantly enhanced (R2 = 0.91–0.95), but the exposure reduction of an occupant following remediation is less than that predicted using the NRPB protoco

    Domestic radon remediation of U.K. dwellings by sub-slab depressurisation: evidence for a baseline contribution from constructional materials

    No full text
    To quantify the effectiveness of Sub-Slab Depressurisation, widely used in the United Kingdom (U.K.) to mitigate indoor radon gas levels in residential properties, a study was made of radon concentration data collected from a set of 170 homes situated in Radon Affected Areas in Northamptonshire and neighbouring counties, remediated using conventional sump/pump technology. A high incidence of satisfactory remediation outcomes was achieved, with 100% of the houses remediated demonstrating post-remediation radon concentrations below the U.K. domestic Action Level of 200 Bq m− 3, while more than 75% of the sample exhibited radon mitigation factors (defined as the ratio of radon concentrations following and prior to remediation) < 0.2. Two systematic trends are identified. Firstly, absolute radon concentration reduction following remediation is directly proportional to initial radon concentration, with a mean reduction factor of 0.96 and a residual component of around 75 Bq m− 3. Secondly, houses with lower initial radon concentrations demonstrate poorer (higher) mitigation factors. These observations support a model in which the total indoor radon concentration within a dwelling can be represented by two principal components, one susceptible to mitigation by sub-slab depressurisation, the other remaining essentially unaffected. The first component can be identified with radon emanating from the subsoil and bedrock geologies, percolating through the foundations of the dwelling as a component of the soil-gas, and potentially capable of being attenuated by sub-slab depressurisation or radon-barrier remediation technologies. The second contribution can be identified with radon emanating from materials used in the construction of the dwelling with a further contribution from the natural background level, and is essentially unaffected by ground-level remediation strategies. Modelling of a multi-component radon dependency using ground-radon attenuation factors derived from the experimental data, in conjunction with typical background and structural-radon levels, yields behaviour in good agreement with the observed dependence of mitigation factor on initial radon concentratio

    Radon mitigation in domestic properties and its health implications - a comparison between during-construction and post-construction radon reduction

    No full text
    Although United Kingdom (UK) Building Regulations applicable to houses constructed since 1992 in Radon Affected Areas address the health issues arising from the presence of radon in domestic properties and specify the installation of radon-mitigation measures during construction, no legislative requirement currently exists for monitoring the effectiveness of such remediation once construction is completed and the houses are occupied. To assess the relative effectiveness of During-Construction radon reduction and Post-Construction remediation, radon concentration data from houses constructed before and after 1992 in Northamptonshire, UK, a designated Radon Affected Area, was analysed. Post-Construction remediation of 73 pre-1992 houses using conventional fan-assisted sump technology proved to be extremely effective, with radon concentrations reduced to the Action Level, or below, in all cases. Of 64 houses constructed since 1992 in a well-defined geographical area, and known to have had radon-barrier membranes installed during construction, 11% exhibited radon concentrations in excess of the Action Level. This compares with the estimated average for all houses in the same area of 17%, suggesting that, in some 60% of the houses surveyed, installation of a membrane has not resulted in reduction of mean annual radon concentrations to below the Action Level. Detailed comparison of the two data sets reveals marked differences in the degree of mitigation achieved by remediation. There is therefore an ongoing need for research to resolve definitively the issue of radon mitigation and to define truly effective anti-radon measures, readily installed in domestic properties at the time of construction. It is therefore recommended that mandatory testing be introduced for all new houses in Radon Affected Area

    Time-integrating radon gas measurements in domestic premises:  comparison of short-, medium- and long-term exposures

    No full text
    To identify the most applicable technology for the short-term assessment of domestic radon levels, comparative assessments of a number of integrating detector types, including track-etch, electret and activated charcoal were undertaken. Thirty-four unremediated dwellings in a high-radon area were monitored using track-etch detectors exposed for one-month and three-month periods. In parallel, one-week measurements were made in the same homes at one-month intervals, using co-located track-etch, charcoal and electret detectors exposed simultaneously, while three of the homes were also monitored by continuous-sampling detectors at hourly intervals over extended periods. Calibration of dose-integrating devices against each other and against continuous-monitoring systems confirmed good responsivity and linearity. Although track-etch, charcoal and electret devices are suitable in principle for one-week measurements, zero-exposure offset and natural radon variability cause many one-week results to be equivocal, necessitating repetition of the measurement. One-week exposures can be reliable indicators in low-radon areas or for new properties, but in high-radon areas, the use of three-month exposures is indicated. This analysis also established confidence limits for short-term measurement
    corecore