7,365 research outputs found

    The viscoelastic behavior of a composite in a thermal environment

    Get PDF
    A proposed method for the accelerated predictions of modulus and life times for time dependent polymer matrix composite laminates is presented. The method, based on the time temperature superposition principle and lamination theory, is described in detail. Unidirectional reciprocal of compliance master curves and the shift functions needed are presented and discussed. Master curves for arbitrarily oriented unidirectional laminates are predicted and compared with experimantal results obtained from master curves generated from 15 minute tests and with 25 hour tests. Good agreement is shown. Predicted 30 deg and 60 deg unidirectional strength master curves are presented and compared to results of creep rupture tests. Reasonable agreement is demonstrated. In addition, creep rupture results for a (90 deg + or - 60 deg/90 deg) sub 2s laminate are presented

    Calibration of isotopologue-specific optical trace gas analysers: a practical guide

    Get PDF
    The isotopic composition of atmospheric trace gases such as CO2 and CH4 provides a valuable tracer for the sources and sinks that contribute to atmospheric trace gas budgets. In the past, isotopic composition has typically been measured with high precision and accuracy by isotope ratio mass spectrometry (IRMS) offline and separately from real-time or flask-based measurements of concentrations or mole fractions. In recent years, development of infrared optical spectroscopic techniques based on laser and Fourier-transform infrared spectroscopy (FTIR) has provided high-precision measurements of the concentrations of one or more individual isotopologues of atmospheric trace gas species in continuous field and laboratory measurements, thus providing both concentration and isotopic measurements simultaneously. Several approaches have been taken to the calibration of optical isotopologue-specific analysers to derive both total trace gas amounts and isotopic ratios, converging into two different approaches: calibration via the individual isotopologues as measured by the optical device and calibration via isotope ratios, analogous to IRMS.This paper sets out a practical guide to the calculations required to perform calibrations of isotopologue-specific optical analysers, applicable to both laser and broadband FTIR spectroscopy. Equations to calculate the relevant isotopic and total concentration quantities without approximation are presented, together with worked numerical examples from actual measurements. Potential systematic errors, which may occur when all required isotopic information is not available, or is approximated, are assessed. Fortunately, in most such realistic cases, these systematic errors incurred are acceptably small and within the compatibility limits specified by the World Meteorological Organisation – Global Atmosphere Watch. Isotopologue-based and ratio-based calibration schemes are compared. Calibration based on individual isotopologues is simpler because the analysers fundamentally measure amounts of individual isotopologues, not ratios. Isotopologue calibration does not require a range of isotopic ratios in the reference standards used for the calibration, only a range of concentrations or mole fractions covering the target range. Ratio-based calibration leads to concentration dependence, which must also be characterised.</p

    XO-2b: a hot Jupiter with a variable host star that potentially affects its measured transit depth

    Full text link
    The transiting hot Jupiter XO-2b is an ideal target for multi-object photometry and spectroscopy as it has a relatively bright (VV-mag = 11.25) K0V host star (XO-2N) and a large planet-to-star contrast ratio (Rp_{p}/Rs0.015_{s}\approx0.015). It also has a nearby (31.21") binary stellar companion (XO-2S) of nearly the same brightness (VV-mag = 11.20) and spectral type (G9V), allowing for the characterization and removal of shared systematic errors (e.g., airmass brightness variations). We have therefore conducted a multiyear (2012--2015) study of XO-2b with the University of Arizona's 61" (1.55~m) Kuiper Telescope and Mont4k CCD in the Bessel U and Harris B photometric passbands to measure its Rayleigh scattering slope to place upper limits on the pressure-dependent radius at, e.g., 10~bar. Such measurements are needed to constrain its derived molecular abundances from primary transit observations. We have also been monitoring XO-2N since the 2013--2014 winter season with Tennessee State University's Celestron-14 (0.36~m) automated imaging telescope to investigate stellar variability, which could affect XO-2b's transit depth. Our observations indicate that XO-2N is variable, potentially due to {cool star} spots, {with a peak-to-peak amplitude of 0.0049±0.00070.0049 \pm 0.0007~R-mag and a period of 29.89±0.1629.89 \pm 0.16~days for the 2013--2014 observing season and a peak-to-peak amplitude of 0.0035±0.00070.0035 \pm 0.0007~R-mag and 27.34±0.2127.34 \pm 0.21~day period for the 2014--2015 observing season. Because of} the likely influence of XO-2N's variability on the derivation of XO-2b's transit depth, we cannot bin multiple nights of data to decrease our uncertainties, preventing us from constraining its gas abundances. This study demonstrates that long-term monitoring programs of exoplanet host stars are crucial for understanding host star variability.Comment: published in ApJ, 9 pages, 11 figures, 3 tables; updated figures with more ground-based monitoring, added more citations to previous work

    Measurement of Linear Stark Interference in 199Hg

    Full text link
    We present measurements of Stark interference in the 61S0^1S_0 \rightarrow 63P1^3P_1 transition in 199^{199}Hg, a process whereby a static electric field EE mixes magnetic dipole and electric quadrupole couplings into an electric dipole transition, leading to EE-linear energy shifts similar to those produced by a permanent atomic electric dipole moment (EDM). The measured interference amplitude, aSIa_{SI} = (aM1+aE2)(a_{M1} + a_{E2}) = (5.8 ±\pm 1.5)×109\times 10^{-9} (kV/cm)1^{-1}, agrees with relativistic, many-body predictions and confirms that earlier central-field estimates are a factor of 10 too large. More importantly, this study validates the capability of the 199^{199}Hg EDM search apparatus to resolve non-trivial, controlled, and sub-nHz Larmor frequency shifts with EDM-like characteristics.Comment: 4 pages, 4 figures, 1 table; revised in response to reviewer comment

    Improved limit on the permanent electric dipole moment of 199Hg

    Full text link
    We report the results of a new experimental search for a permanent electric dipole moment of 199Hg utilizing a stack of four vapor cells. We find d(199Hg) = (0.49 \pm 1.29_stat \pm 0.76_syst) x 10^{-29} e cm, and interpret this as a new upper bound, |d(199Hg)| < 3.1 x 10^{-29} e cm (95% C.L.). This result improves our previous 199Hg limit by a factor of 7, and can be used to set new constraints on CP violation in physics beyond the standard model.Comment: 4 pages, 4 figures. additional reference, minor edits in response to reviewer comment

    A Fourier transform infrared trace gas and isotope analyser for atmospheric applications

    Get PDF
    Concern in recent decades about human impacts on Earth's climate has led to the need for improved and expanded measurement capabilities of greenhouse gases in the atmosphere. In this paper we describe in detail an in situ trace gas analyser based on Fourier Transform Infrared (FTIR) spectroscopy that is capable of simultaneous and continuous measurements of carbon dioxide (CO&lt;sub&gt;2&lt;/sub&gt;), methane (CH&lt;sub&gt;4&lt;/sub&gt;), carbon monoxide (CO), nitrous oxide (N&lt;sub&gt;2&lt;/sub&gt;O) and &lt;sup&gt;13&lt;/sup&gt;C in CO&lt;sub&gt;2&lt;/sub&gt; in air with high precision. High accuracy is established by reference to measurements of standard reference gases. Stable water isotopes can also be measured in undried airstreams. The analyser is automated and allows unattended operation with minimal operator intervention. Precision and accuracy meet and exceed the compatibility targets set by the World Meteorological Organisation – Global Atmosphere Watch for baseline measurements in the unpolluted troposphere for all species except &lt;sup&gt;13&lt;/sup&gt;C in CO&lt;sub&gt;2&lt;/sub&gt;. &lt;br&gt;&lt;br&gt; The analyser is mobile and well suited to fixed sites, tower measurements, mobile platforms and campaign-based measurements. The isotopic specificity of the optically-based technique and analysis allows its application in isotopic tracer experiments, for example in tracing variations of &lt;sup&gt;13&lt;/sup&gt;C in CO&lt;sub&gt;2&lt;/sub&gt; and &lt;sup&gt;15&lt;/sup&gt;N in N&lt;sub&gt;2&lt;/sub&gt;O. We review a number of applications illustrating use of the analyser in clean air monitoring, micrometeorological flux and tower measurements, mobile measurements on a train, and soil flux chamber measurements

    Total column CO_2 measurements at Darwin, Australia – site description and calibration against in situ aircraft profiles

    Get PDF
    An automated Fourier Transform Spectroscopic (FTS) solar observatory was established in Darwin, Australia in August 2005. The laboratory is part of the Total Carbon Column Observing Network, and measures atmospheric column abundances of CO_2 and O_2 and other gases. Measured CO_2 columns were calibrated against integrated aircraft profiles obtained during the TWP-ICE campaign in January–February 2006, and show good agreement with calibrations for a similar instrument in Park Falls, Wisconsin. A clear-sky low airmass relative precision of 0.1% is demonstrated in the CO2 and O2 retrieved column-averaged volume mixing ratios. The 1% negative bias in the FTS X_(CO_2) relative to the World Meteorological Organization (WMO) calibrated in situ scale is within the uncertainties of the NIR spectroscopy and analysis

    Absolute calibration of the intramolecular site preference of 15N fractionation in tropospheric N2O by FT-IR spectroscopy

    Get PDF
    Nitrous oxide (N2O) plays important roles in atmospheric chemistry both as a greenhouse gas and in stratospheric ozone depletion. Isotopic measurements of N2O have provided an invaluable insight into understanding its atmospheric sources and sinks. The preference for 15N fractionation between the central and terminal positions (the “site preference”) is particularly valuable because it depends principally on the processes involved in N2O production or consumption, rather than the 15N content of the substrate from which it is formed. Despite the value of measurements of the site preference, there is no internationally recognized standard reference material of accurately known and accepted site preference, and there has been some lack of agreement in published studies aimed at providing such a standard. Previous work has been based on isotope ratio mass spectrometry (IRMS); in this work we provide an absolute calibration for the intramolecular site preference of 15N fractionation of working standard gases used in our laboratory by a completely independent technique—high-resolution Fourier transform infrared (FT-IR) spectroscopy. By reference to this absolute calibration, we determine the site preference for 25 samples of tropospheric N2O collected under clean air conditions to be 19.8‰ ± 2.1‰. This result is in agreement with that based on the earlier absolute calibration of Toyoda and Yoshida (Toyoda, S. and Yoshida, N. Anal. Chem. 1999, 71, 4711−4718) who found an average tropospheric site preference of 18.7‰ ± 2.2‰. We now recommend an interlaboratory exchange of working standard N2O gases as the next step to providing an international reference standard
    corecore