642 research outputs found

    Topography-based modulation of environmental factors as a mechanism for intertidal microhabitat formation: A basis for marine ecological design.

    Get PDF
    Topographic complexity is often considered to be closely associated with habitat complexity and niche diversity; however, complex topography per se does not imply habitat suitability. Rather, ecologically suitable habitats may emerge if topographic features interact with environmental factors and thereby alter their surrounding microenvironment to the benefit of local organisms (e.g., resource provisioning, stress mitigation). Topography may thus act as a key modulator of abiotic stressors and biotic pressures, particularly in environmentally challenging intertidal systems. Here, we review how topography can alter microhabitat conditions with respect to four resources required by intertidal organisms: a source of energy (light, suspended food particles, prey, detritus), water (hydration, buffering of light, temperature and hydrodynamics), shelter (temperature, wave exposure, predation), and habitat space (substratum area, propagule settlement, movement). We synthesize mechanisms and quantitative findings of how environmental factors can be altered through topography and suggest an organism-centered 'form-follows-ecological-function' approach to designing multifunctional marine infrastructure

    Neuropathic pain: redefinition and a grading system for clinical and research purposes.

    Get PDF
    Pain usually results from activation of nociceptive afferents by actually or potentially tissue-damaging stimuli. Pain may also arise by activity generated within the nervous system without adequate stimulation of its peripheral sensory endings. For this type of pain, the International Association for the Study of Pain introduced the term neuropathic pain, defined as "pain initiated or caused by a primary lesion or dysfunction in the nervous system." While this definition has been useful in distinguishing some characteristics of neuropathic and nociceptive types of pain, it lacks defined boundaries. Since the sensitivity of the nociceptive system is modulated by its adequate activation (e.g., by central sensitization), it has been difficult to distinguish neuropathic dysfunction from physiologic neuroplasticity. We present a more precise definition developed by a group of experts from the neurologic and pain community: pain arising as a direct consequence of a lesion or disease affecting the somatosensory system. This revised definition fits into the nosology of neurologic disorders. The reference to the somatosensory system was derived from a wide range of neuropathic pain conditions ranging from painful neuropathy to central poststroke pain. Because of the lack of a specific diagnostic tool for neuropathic pain, a grading system of definite, probable, and possible neuropathic pain is proposed. The grade possible can only be regarded as a working hypothesis, which does not exclude but does not diagnose neuropathic pain. The grades probable and definite require confirmatory evidence from a neurologic examination. This grading system is proposed for clinical and research purposes

    Infant EEG activity as a biomarker for autism: a promising approach or a false promise?

    Get PDF
    The ability to determine an infant's likelihood of developing autism via a relatively simple neurological measure would constitute an important scientific breakthrough. In their recent publication in this journal, Bosl and colleagues claim that a measure of EEG complexity can be used to detect, with very high accuracy, infants at high risk for autism (HRA). On the surface, this appears to be that very scientific breakthrough and as such the paper has received widespread media attention. But a close look at how these high accuracy rates were derived tells a very different story. This stems from a conflation between "high risk" as a population-level property and "high risk" as a property of an individual. We describe the approach of Bosl et al. and examine their results with respect to baseline prevalence rates, the inclusion of which is necessary to distinguish infants with a biological risk of autism from typically developing infants with a sibling with autism. This is an important distinction that should not be overlooked

    The World Hip Trauma Evaluation Study 3 HEMIARTHROPLASTY EVALUATION BY MULTICENTRE INVESTIGATION - WHiTE 3: HEMI - AN ABRIDGED PROTOCOL

    Get PDF
    Approximately half of all hip fractures are displaced intracapsular fractures. The standard treatment for these fractures is either hemiarthroplasty or total hip arthroplasty. The recent National Institute for Health and Care Excellence (NICE) guidance on hip fracture management recommends the use of 'proven' cemented stem arthroplasty with an Orthopaedic Device Evaluation Panel (ODEP) rating of at least 3B (97% survival at three years). The Thompsons prosthesis is currently lacking an ODEP rating despite over 50 years of clinical use, likely due to the paucity of implant survival data. Nationally, adherence to these guidelines is varied as there is debate as to which prosthesis optimises patient outcomes.This study design is a multi-centre, multi-surgeon, parallel, two arm, standard-of-care pragmatic randomised controlled trial. It will be embedded within the WHiTE Comprehensive Cohort Study (ISRCTN63982700). The main analysis is a two-way equivalence comparison between Hemi-Thompson and Hemi-Exeter polished taper with Unitrax head. Secondary outcomes will include radiological leg length discrepancy measured as per Bidwai and Willett, mortality, re-operation rate and indication for re-operation, length of index hospital stay and revision at four months. This study will be supplemented by the NHFD (National Hip Fracture Database) dataset.Evidence on the optimum choice of prosthesis for hemiarthroplasty of the hip is lacking. National guidance is currently based on expert opinion rather than empirical evidence. The incidence of hip fracture is likely to continue to increase and providing high quality evidence on the optimumCite this article: A. L. Sims. The World Hip Trauma Evaluation Study 3: Hemiarthroplasty Evaluation by Multicentre Investigation - WHITE 3: HEMI - An Abridged Protocol. Bone Joint Res 2016;5:18-25. doi: 10.1302/2046-3758.51.2000473

    A new concept for the combination of optical interferometers and high-resolution spectrographs

    Full text link
    The combination of high spatial and spectral resolution in optical astronomy enables new observational approaches to many open problems in stellar and circumstellar astrophysics. However, constructing a high-resolution spectrograph for an interferometer is a costly and time-intensive undertaking. Our aim is to show that, by coupling existing high-resolution spectrographs to existing interferometers, one could observe in the domain of high spectral and spatial resolution, and avoid the construction of a new complex and expensive instrument. We investigate in this article the different challenges which arise from combining an interferometer with a high-resolution spectrograph. The requirements for the different sub-systems are determined, with special attention given to the problems of fringe tracking and dispersion. A concept study for the combination of the VLTI (Very Large Telescope Interferometer) with UVES (UV-Visual Echelle Spectrograph) is carried out, and several other specific instrument pairings are discussed. We show that the proposed combination of an interferometer with a high-resolution spectrograph is indeed feasible with current technology, for a fraction of the cost of building a whole new spectrograph. The impact on the existing instruments and their ongoing programs would be minimal.Comment: 27 pages, 9 figures, Experimental Astronomy; v2: accepted versio

    Radiosensitization of hypoxic tumour cells by S-nitroso-N-acetylpenicillamine implicates a bioreductive mechanism of nitric oxide generation

    Get PDF
    The radiosensitizing activity of S-nitroso-N-acetylpenicillamine (SNAP), a nitric oxide (NO) donor, was assessed in a model of non-metabolic hypoxia achieved in an atmosphere of 95% nitrogen–5% carbon dioxide. A 10 min preincubation of hypoxic EMT-6 cells (10 × 106 ml−1) with 0.1 and 1 mM SNAP before radiation resulted in an enhancement ratio of 1.6 and 1.7 respectively. The level of spontaneous NO release, measured by a NO specific microsensor, correlated directly with the concentration of SNAP and was enhanced 50 times in the presence of cells. Dilution of the cell suspension from 10 to 0.1 × 106 ml−1 resulted in a 16-fold decline in NO release, but only a twofold decrease in radiosensitization was observed. Preincubation of hypoxic cells with SNAP for 3 min up to 30 min caused an increasing radiosensitizing effect. Extended preincubation of 100 min led to the loss of radiosensitization although the half-life of SNAP is known to be 4–5 h. Taken together, these observations suggest that SNAP generates NO predominantly by a bioreductive mechanism and that its biological half-life is unlikely to exceed 30 min. The lack of correlation between free NO radical and radiosensitizing activity may reflect a role of intracellular NO adducts which could contribute to radiosensitization as well. © 1999 Cancer Research Campaig

    Quality Measures for the Diagnosis and Non-Operative Management of Carpal Tunnel Syndrome in Occupational Settings

    Get PDF
    Introduction: Providing higher quality medical care to workers with occupationally associated carpal tunnel syndrome (CTS) may reduce disability, facilitate return to work, and lower the associated costs. Although many workers’ compensation systems have adopted treatment guidelines to reduce the overuse of unnecessary care, limited attention has been paid to ensuring that the care workers do receive is high quality. Further, guidelines are not designed to enable objective assessments of quality of care. This study sought to develop quality measures for the diagnostic evaluation and non-operative management of CTS, including managing occupational activities and functional limitations. Methods: Using a variation of the well-established RAND/UCLA Appropriateness Method, we developed draft quality measures using guidelines and literature reviews. Next, in a two-round modified-Delphi process, a multidisciplinary panel of 11 U.S. experts in CTS rated the measures on validity and feasibility. Results: Of 40 draft measures, experts rated 31 (78%) valid and feasible. Nine measures pertained to diagnostic evaluation, such as assessing symptoms, signs, and risk factors. Eleven pertain to non-operative treatments, such as the use of splints, steroid injections, and medications. Eleven others address assessing the association between symptoms and work, managing occupational activities, and accommodating functional limitations. Conclusions: These measures will complement existing treatment guidelines by enabling providers, payers, policymakers, and researchers to assess quality of care for CTS in an objective, structured manner. Given the characteristics of previous measures developed with these methods, greater adherence to these measures will probably lead to improved patient outcomes at a population level

    Does ligament balancing technique affect kinematics in rotating platform, PCL retaining knee arthroplasties?: A prospective randomized study

    Get PDF
    The goal of this prospective, randomized, blinded trial was to determine if ligament balancing techniques for rotating platform TKA affect postoperative knee kinematics. Sixteen patients with unilateral rotating platform TKA consented to participate in this institutional review board approved study. Eight patients were randomly selected to receive ligament balancing with an instrumented joint spreader device and eight patients received ligament balancing using fixed thickness spacer blocks. A single plane shape matching technique was used for kinematic analysis of static deep knee flexion and dynamic stair activities. There were no differences in knee kinematics between groups during static deep flexion activities. The spreader group demonstrated kinematics more similar to the normal knee during the ascending phase of the dynamic stair activity. Knee kinematics in static knee flexion were unaffected by ligament balancing technique, while knees balanced with the spreader demonstrated a medial pivot motion pattern during stair ascent. This medial pivot motion pattern may improve long-term results by more closely replicating normal knee kinematics

    Polyethylene thickness is a risk factor for wear necessitating insert exchange

    Get PDF
    PURPOSE: The aim of this observational study was to investigate the optimal minimal polyethylene (PE) thickness in total knee arthroplasty (TKA) and identify other risk factors associated with revision of the insert due to wear. METHODS: A total of 84 TKA were followed for 11-16 years. All patients received the same prosthesis design (Interax; Howmedica/ Stryker) with halfbearings: separate PE-inserts medially and laterally. Statistical analysis comprised Cox-regression to correct for confounding. RESULTS: Eight knees (9.5%) had been revised due to thinning inserts and an additional patient is scheduled for revision. PE thickness, diagnosis, BMI and weight are risk factors for insert exchange. For each millimetre decrease in PE thickness, the risk of insert exchange increases 3.0 times, which remains after correction for age, gender, weight, diagnosis and femoral-tibial angle. Insert exchange was 4.73 times more likely in OA-patients compared to RA-patients. For every unit increase in BMI and weight the risk for insert exchange increases 1.40 times and 1.14 times, respectively. CONCLUSIONS: In conclusion we therefore advise against the use of thin PE inserts in modular TKA and recommend PE inserts with a minimal 8-mm thickness.Optimising joint reconstruction management in arthritis and bone tumour patient
    corecore