    The use of parafolmaldehyde tablets by Brazilian health institutions: part I

    Get PDF
    A national survey was accomplished next to 6907 health Institutions through a questionnaire to explore and to describe the use of Parafolmaldehyde Tablets as microbicide agent. There was a return of 443 (6.41%) correspondences which 253 (57,89%) affirmed to apply this chemical agent. Several articles of medical-hospitable use with indication to sterilization through autoclaves, are processed by Parafolmaldehyde Tablets in the researched Institutions, demonstrating inadequate criteria in choosing the process. Another detected inadequate use of Parafolmaldehyde Tablets was in the processing of articles with lumens and the density materials due to the low penetrability of the gas. The nurses' perception with reference to the perspectives of Parafolmaldehyde Tablets's use as sterilizing chemical agent, in environmental conditions is of disuse, pointing for a search of safer technologies.Um levantamento nacional foi realizado junto às 6907 Instituições de Saúde, por meio de um questionário com o objetivo de reconhecer e descrever o uso das pastilhas de Paraformaldeído como agente microbicida. Houve um retorno de 443 (6,41%) correspondências das quais 253 (57,89%) afirmaram fazer uso deste agente químico. Vários artigos de uso médico-hospitalares com indicação de esterilização por autoclavação, são processados por meio das pastilhas de Paraformaldeído nas Instituições pesquisadas, demonstrando critérios norteadores inadequados na escolha do processo. Considerando-se a baixa difusibilidade do gás em questão, um outro uso inadequado detectado das pastilhas de Paraformaldeído foi no processamento de artigos com lúmens e os de densidade. A percepção das enfermeiras quanto às perspectivas do uso das pastilhas de Paraformaldeído, como agente químico esterilizante, em condições ambientais é de desuso, apontando para uma busca de tecnologias mais seguras

    Controle da hipotermia de pacientes cirúrgicos idosos no intraoperatório: avaliação de duas intervenções de enfermagem

    Get PDF
    O objetivo deste estudo foi verificar a eficácia de duas intervenções de enfermagem no controle da perda de temperatura corporal, utilizando cobertores no intra-operatório de pacientes cirúrgicos idosos. O estudo foi experimental, comparativo, de campo, aplicado, longitudinal prospectiva, com abordagem quantitativa. Oitenta e um idosos, sob cirurgia eletiva, com tempo cirúrgico mínimo de uma hora, foram divididos através de amostragem probabilística sistemática em dois grupos experimentais e um controle. Os dados foram coletados por medida biofisiológica, através de termômetro timpânico. Após demonstrar homogeneidade das variáveis - sexo, porte cirúrgico, idade, índice de massa corpórea (IMC), anestesia, temperatura e umidade ambiente, drogas e infusão líquida -, as intervenções foram comparadas entre si. A incidência de hipotermia (59,3%) e média de perda de calor corporal (E1=-0,6ºC , E2=-0,6ºC e C=-0,7ºC) não foram estatisticamente diferentes entre os grupos (p=0,85 e p=0,7, respectivamente). Os resultados demonstram necessidade de métodos adicionais de aquecimento corporal para manutenção da temperatura.OBJETIVO: Verificar la eficacia de dos intervenciones de enfermería en el control de la pérdida de temperatura corporal, utilizando mantas, en el intraoperatorio de pacientes quirúrgicos ancianos. MÉTODO: La investigación fue experimental, comparativa, de campo, aplicada, longitudinal prospectiva, con aproximación cuantitativa. Ochenta y uno ancianos, bajo cirugía electiva, con tiempo quirúrgico mínimo de una hora, fueron divididos a través de muestra probabilística, sistemática en dos grupos experimentales y un control. Los datos fueron recolectados por medida biofisiológica, a través de termómetro timpánico. RESULTADOS: Tras demostrar la homogeneidad de las variables: sexo, porte quirúrgico, edad, IMC, anestesia, temperatura y humedad ambiente, drogas e infusión líquida, las intervenciones fueron comparadas entre si. La incidencia de hipotermia y promedio de pérdida de calor corporal (E1=-0,6ºC, E2=-0,6oC y C=-0,7ºC) no han sido estadísticamente diferentes entre grupos (p=0,85 e p=0,7 respectivamente).CONCLUSIÓN: Los resultados han demostrado la necesidad de métodos adicionales de calentamiento corporal para manutención de la temperatura.OBJECTIVES: To evaluate the efficacy of two different nursing interventions regarding control of body heat loss, using blankets during the intraoperative period of elderly patients. METHODS: This was an experimental, comparative, applied, longitudinal prospective study with a quantitative approach. Eighty-one elderly patients undergoing elective surgery with a surgical time frame of at least one hour were selected by systematic probability sampling into two Experimental and one Control Group. Informed consent was obtained from participants. Data was collected by biophysiological measurement, using a tympanic thermometer. RESULTS: After the homogeneity of variables - gender, surgical duration, age, BMR, anesthesia, room humidity and temperature, drugs and liquid infusion- had been demonstrated, the interventions were confronted. Incidence of hypothermia (59.3%) and body heat loss (E1=-0.6ºC , E2=-0.6oC and C=-0.7ºC) were not significantly different between the groups (p=0.85 and p=0.7 respectively). CONCLUSIONS: Results show the need for associated extra body warming methods to maintain normothermia

    Construction and Adaptation of Management and health care measures in nursing

    Get PDF

    Compatibilidades e incompatibilidades entre rayos gama y óxido de etileno como métodos sucesivos de esterilización

    Get PDF
    A dúvida sobre a questão da re-esterilização de artigos confeccionados com cloreto de polivinila (PVC), esterilizados em radiação gama (RG) e posteriormente em óxido de etileno (EO) persiste até os dias atuais. Por meio da revisão integrativa da literatura, este artigo analisou estudos que evidenciaram compatibilidades e incompatibilidades entre os processos de esterilização com RG e EO quando utilizados como métodos sucessivos de esterilização. Foram analisados 7 estudos. Constatou-se que há influência multifatorial na segurança do procedimento e que o método analítico da cromatografia empregado na maioria dos estudos produziu resultados controversos. Esse fato indica a necessidade da realização de novos estudos sobre o assunto, utilizando-se métodos analíticos mais sensíveis do que a cromatografia gasosa, como o teste de reatividade biológica em culturas celulares, que poderá dirimir em nosso meio a crônica dúvida da compatibilidade ou incompatibilidade de se esterilizar em EO materiais previamente gamairradiados.The doubt regarding the re-sterilization of articles made of polyvinyl chloride (PVC) sterilized with gamma radiation (GR) and subsequently with ethylene oxide (EO) persists to date. Through a systematic literature review, this article analyzed studies that demonstrated compatibilities and incompatibilities between the sterilization processes with GR and EO, when used as consecutive sterilization methods. Seven studies were analyzed. It was verified that there is a multifactor influence regarding the safety of the procedure and that the chromatography analytical method employed by most studies yielded controversial results. This fact indicates the need for further studies on the issue, using more sensitive analytical methods than gas chromatography, such as the biological reactivity test in cell cultures, in an attempt to clarify the chronic doubt regarding the adequacy or inadequacy of sterilizing previously gamma-irradiated materials with EtO.La duda sobre la cuestión de la reesterilización de artículos confeccionados con policloruro de vinilo (PVC) esterilizados con Rayos Gamma (RG) y posteriormente en óxido de etileno (EO) persiste hasta la actualidad. A través de la revisión integradora de la literatura, este artículo analizó estudios que evidenciaron compatibilidades e incompatibilidades entre los procesos de esterilización con RG y EO, cuando se utilizan en forma sucesiva. Fueron analizados 7 estudios. Se constató que hay influencia multifactorial en la seguridad del procedimiento y que el método analítico de cromatografía empleado en la mayoría de los estudios generó resultados controversiales. Este hecho indica la necesidad de realizar nuevos estudios sobre el asunto, utilizando métodos analíticos más sensibles que la cromatografía gaseosa, tales como el test de reactividad biológica en cultivos celulares para dirimir en nuestro medio la crónica duda de la compatibilidad o incompatibilidad de esterilizar en EO materiales previamente irradiados con Rayos Gamma

    Paraformaldehyde Tablets microbiological activity reproducing the use conditions of the Brazilian health Institutions

    Get PDF
    A atividade antimicrobiana das Pastilhas de Paraformaldeído, reproduzindo as condições de uso das Instituições de Saúde do Brasil (sem o aquecimento, sem o acréscimo da umidade relativa, a 5%, por um período longo de exposição de 12 horas), foi avaliada "in vitro" por meio do monitoramento microbiológico, segundo a metodologia da AOAC, adotada oficialmente pelo Ministério da Saúde do Brasil para o registro dessa categoria de produtos. Os resultados dos experimentos refutaram a ação esterilizante das Pastilhas de Paraformaldeído nestas condições. Diante destes resultados, realizou-se, então, os testes para avaliação desinfetante do produto utilizando-se o Método de Diluição de Uso, preconizada pela AOAC, adaptado para produtos gasosos, contra os microrganismos teste padronizados Staphylococcus aureus (ATCC nº. 6538), Samonella choleraesuis (ATCC nº. 10708) e Pseudomonas aeruginosa (ATCC nº. 15442). Nestes experimentos, os resultados das culturas mostraram-se 100% negativos contra todas as bactérias testadas inferindo-se indícios de atividade desinfetante de alto nível.La actividad antimicrobiana de las Pastillas de Paraformaldehído, reproduciendo las condiciones de uso en las Instituciones de Salud del Brasil (sin el calentamiento y aumento de la humedad relativa, en un porcentaje del 0,5%, pese al largo período de exposición de 12 horas), fue evaluada "in vitro" por medio del monitoramiento microbiológico, según la metodología de la AOAC, adoptada oficialmente por el Ministerio de Salud del Brasil para el registro de esa categoría de produtos. Los resultados de los experimentos refutaron la acción esterilizante de las Pastillas de Paraformaldehído en las condiciones estudiadas. Frente a estos resultados se realizó, entonces, los test para evaluación desinfectante del produto utilizándose el Método de Dilución de Uso, preconizada por la AOAC, adaptado para productos gaseosos, contra los microorganismos test patronizados Staphylococcus aureus (ATCC nº. 6538), Samonella choleraesuis (ATCC nº. 10708) e Pseudomonas aeruginosa (ATCC nº. 15442). En estos experimentos, los resultados de los cultivos se mostraron 100% negativos contra todas las bacterias probadas. Los resultados microbiológicos nos permiten inferir que las Pastillas de Paraformaldehído mostró indícios de actividad desinfectante de alto nivel.The sterilizing activity of Parafolmaldehyde Tablets reproducing the conditions of use in the Brazilian health Institutions (without the heating, without increment of the relative humidity, in 0.5%, even for a long period of exhibition of 12 hours) was evaluated "in vitro" by microbiologic monitoring, according to the methodology of the AOAC, officially adopted by the Brazilian Health Ministry for registration of that category of products. The results of the experiments refuted the sterilizing action of Parafolmaldehyde Tablets in this conditions. Thus, it was evaluated the disinfectant action of the product using the vegetative bacterias by Use Dilution Method, preconized for AOAC and adapted for gaseous products, against the tests microorganisms standardized Staphylococcus aureus (ATCC n. 6538), Samonella choleraesuis (ATCC n. 10708) and Pseudomonas aeruginosa (ATCC n. 15442). In these experiments, the results of the cultures showed 100% negative against all the tested bacterias inferring indications of disinfectant activity of high level action

    Avaliação da manutenção da esterilidade de materiais úmidos/molhados após a esterilização por vapor e armazenamento por 30 dias

    Get PDF
    Moist/wet materials stored after autoclaving are considered contaminated and not recommended for use. This study evaluates the maintenance of sterility in moist/wet material after being submitted to steam sterilization and stored for a period of 30 days. Aiming to support decision-making in emergency situations, 40 surgical boxes packed in nonwoven cloth covering Spunbound, Metblouwn, Spunbound (SMS): half (the experimental group) were placed in an autoclave but the drying phase was interrupted, yielding moist/wet materials and the other half (the negative control group) underwent the complete cycle. The external parts of each surgical box were deliberately contaminated with Serratia marcescens and subsequently stored for 30 days. After this period, the boxes' contents were submitted to sterility tests and no growth was observed. The presence of moisture inside the surgical boxes did not interfere with maintaining their sterility.Se consideran como contaminados los objetos mojados/húmedos almacenados después de ser esterilizados en autoclave, no siendo recomendados para uso. El objetivo del estudio fue evaluar la manutención de la esterilidad de los materiales mojados/húmedos después de sometidos al proceso de esterilización por vapor y almacenados por un intervalo de 30 días. Con la finalidad de auxiliar en la toma de decisiones en situaciones de emergencia, fueron preparadas 40 cajas quirúrgicas embaladas en SMS, siendo la mitad (experimental) sometidas a un proceso de esterilización en autoclave, con fase de secado interrumpida, liberando material mojado/húmedo y otras 20 (control) con el ciclo completo. Las partes externas de cada caja fueron intencionalmente contaminadas con Serratia marcescens y posteriormente almacenadas por 30 días. Después ese período, los contenidos de las cajas fueron sometidos a pruebas de esterilidad, acusando ausencia total de crecimiento. La presencia de humedad dentro de las cajas no interfirió en la manutención de la esterilidad de su contenido.Consideram-se contaminados os artigos molhados/úmidos, armazenados após autoclavação, não sendo recomendados para uso. O objetivo do estudo foi avaliar a manutenção da esterilidade dos materiais molhados/úmidos, após terem sido submetidos ao processo de esterilização pelo vapor e armazenados por intervalo de 30 dias. Com a finalidade de auxiliar a tomada de decisão em situações emergenciais, foram preparadas 40 caixas cirúrgicas, embaladas em SMS, sendo a metade (experimental) submetida a autoclavação, com fase de secagem interrompida, liberando material molhado/úmido e outras 20 (controle) ao ciclo completo. As partes externas de cada caixa foram propositalmente contaminadas com Serratia marcescens e, posteriormente, armazenadas por 30 dias. Após esse período, os conteúdos das caixas foram submetidos a testes de esterilidade, acusando ausência total de crescimento. A presença de umidade dentro das caixas não interferiu na manutenção da esterilidade do seu conteúdo

    Avaliação microbiológica das diferentes formulações anti-sépticas, polivinilpirrolidona-iodo e clorexidina, após contaminação intencional das almotolias

    Get PDF
    This study aimed to evaluate the survival rate of microorganisms within different antiseptic formulations - povidone-iodine (PVP-I) and chlorhexidine (CHX) - after intentional contamination, and to establish the minimum care necessary to ensure sterilization of non-disposable antiseptic solution containers. A laboratory study was performed with 180 antiseptic containers, which were contaminated with Serratia marcescens [1 x 105 UFC/mL]. The containers were closed and stored, at room temperature, during seven days and shaken daily. The antiseptic cultures were evaluated to be 100% negative to Serratia marcescens in all of the non-disposable containers. These results suggested that antiseptic solutions inactivate microorganisms [1 x 105 UFC/mL]. Since cleaned antiseptic containers have around 102 UFC coming from tap water, it can be inferred that cleansing is a safe minimum procedure to ensure reuse of containers for distribution of CHX and PVP-I solutions in aqueous, detergent and alcoholic formulations.Los objetivos de este estudio fueron evaluar la sobre vivencia de los micro organismos en las diferentes formulaciones de los antisépticos clorexidina (CHX) y polivinil-pirrolidona-yodo (PVP-Y), después de una contaminación intencional de los recipientes y extrapolar los resultados de los laboratorios para el cuidado mínimo a ser dispensado a los recipientes de múltiple uso para el envase de los antisépticos probados. Para esto, fue desarrollado un estudio de laboratorio, en que 180 recipientes fueron contaminados con 1 x 105 UFC/mL de suspensión conteniendo S.marcescens. Después de la contaminación, seis diferentes formulaciones de antisépticos (clorexidina y PVP-Y en los vehículos alcohólico, detergente y acuoso) fueron distribuidos y sometidos a la cultura diaria durante siete días, a fin de verificar se hubo crecimiento del microorganismo. Los resultados de esta investigación permiten recomendar la limpieza como el procedimiento mínimo en el procesamiento de esos recipientes que garantiza la seguridad de su utilización repetida para distribución de los antisépticos que fueron sometidos a prueba - CHX y PVP-Y.Os objetivos deste estudo foram: avaliação da sobrevivência dos microrganismos nas diferentes formulações dos anti-sépticos clorexidina (CHX) e polivinilpirrolidona-iodo (PVP-I), após contaminação intencional das almotolias, e extrapolar os resultados laboratoriais para o cuidado mínimo a ser dispensado às almotolias de múltiplo uso para o envase dos anti-sépticos testados. Para tanto, foi desenvolvido estudo laboratorial, em que 180 almotolias foram contaminadas com 1 x 105 UFC/mL de suspensão, contendo S.marcescens. Após a contaminação, seis diferentes formulações de anti-sépticos (clorexidina e PVP-I nos veículos alcoólico, degermante e aquoso) foram distribuídas e submetidas à cultura diária durante sete dias, a fim de verificar se houve crescimento do microrganismo. Os resultados desta investigação permitem a recomendação de que a limpeza como procedimento mínimo no processamento desses recipientes garante a segurança de sua utilização repetida para distribuição dos anti-sépticos testados - CHX e PVP-I

    Los hilos de sutura quirúrgicas y la enfermera de centro quirúrgico: criterios de previsión y provisión según la naturaleza de las instituciones hospitalarias

    Get PDF
    O estudo identificou e descreveu os critérios adotados pelas enfermeiras na seleção dos fios de sutura cirúrgica para a elaboração da sua previsão e posterior provisão das Unidades de Centro Cirúrgico, segundo a natureza pública ou privada das instituições hospitalares. Os dados foram coletados por meio de entrevista estruturada e participaram do estudo 74 hospitais do município de São Paulo. A maioria dos hospitais pertence à rede privada e de porte médio, com Centro Cirúrgico geral e até 500 procedimentos/mês. A natureza determina a modalidade de aquisição, tipos de procedimentos cirúrgicos e a variedade de fios adquiridos. As enfermeiras participam dos processos de aquisição, distribuição e utilização de fios de sutura.El estudio identificó y describió los criterios adoptados por las enfermeras al seleccionar los hilos de sutura quirúrgica para hacer la planificación y posterior adquisición de los mismos para cada unidad de Cirugía, con variables según el tipo de institución hospitalaria, ya sea pública o privada. Los datos fueron obtenidos por medio de entrevistas estructuradas realizadas en 74 hospitales del municipio del Estado de São Paulo, Brasil. La mayoría de los hospitales de la red privada se clasifican como de porte medio, con una unidad de Cirugía General y hasta 500 procedimientos por mes. La naturaleza de la Institución determina la modalidad de adquisición, tipos de procedimientos quirúrgicos y la variedad de hilos de sutura adquiridos. Las enfermeras participan de los procesos de adquisición, distribución y uso de los hilos de sutura.The study has identified and described criteria adopted by the nurses in selecting and calculating quantities of surgical sutures to supply the Surgical Center, according to the public or private nature of the surgical centers. The data were collected using structured questionnaires in 74 hospitals within the municipality of São Paulo. The majority of hospitals are medium in size and privately owned with a general Operation Room and up to 500 surgical procedures performed per month. The procedures, the type and the variety of surgical sutures are related to the nature of hospital management. However, there are no criteria to select surgical sutures and their distribution in the operation rooms. The nurses participate on the procedures for purchasing, distribution and use of the surgical sutures

    Microbiological evaluation of different antiseptic povidone-iodine and chlorhexidine formulations after intentional contamination of containers

    Get PDF
    This study aimed to evaluate the survival rate of microorganisms within different antiseptic formulations - povidone-iodine (PVP-I) and chlorhexidine (CHX) - after intentional contamination, and to establish the minimum care necessary to ensure sterilization of non-disposable antiseptic solution containers. A laboratory study was performed with 180 antiseptic containers, which were contaminated with Serratia marcescens [1 x 105 UFC/mL]. The containers were closed and stored, at room temperature, during seven days and shaken daily. The antiseptic cultures were evaluated to be 100% negative to Serratia marcescens in all of the non-disposable containers. These results suggested that antiseptic solutions inactivate microorganisms [1 x 105 UFC/mL]. Since cleaned antiseptic containers have around 102 UFC coming from tap water, it can be inferred that cleansing is a safe minimum procedure to ensure reuse of containers for distribution of CHX and PVP-I solutions in aqueous, detergent and alcoholic formulations.Los objetivos de este estudio fueron evaluar la sobre vivencia de los micro organismos en las diferentes formulaciones de los antisépticos clorexidina (CHX) y polivinil-pirrolidona-yodo (PVP-Y), después de una contaminación intencional de los recipientes y extrapolar los resultados de los laboratorios para el cuidado mínimo a ser dispensado a los recipientes de múltiple uso para el envase de los antisépticos probados. Para esto, fue desarrollado un estudio de laboratorio, en que 180 recipientes fueron contaminados con 1 x 105 UFC/mL de suspensión conteniendo S.marcescens. Después de la contaminación, seis diferentes formulaciones de antisépticos (clorexidina y PVP-Y en los vehículos alcohólico, detergente y acuoso) fueron distribuidos y sometidos a la cultura diaria durante siete días, a fin de verificar se hubo crecimiento del microorganismo. Los resultados de esta investigación permiten recomendar la limpieza como el procedimiento mínimo en el procesamiento de esos recipientes que garantiza la seguridad de su utilización repetida para distribución de los antisépticos que fueron sometidos a prueba - CHX y PVP-Y.Os objetivos deste estudo foram: avaliação da sobrevivência dos microrganismos nas diferentes formulações dos anti-sépticos clorexidina (CHX) e polivinilpirrolidona-iodo (PVP-I), após contaminação intencional das almotolias, e extrapolar os resultados laboratoriais para o cuidado mínimo a ser dispensado às almotolias de múltiplo uso para o envase dos anti-sépticos testados. Para tanto, foi desenvolvido estudo laboratorial, em que 180 almotolias foram contaminadas com 1 x 105 UFC/mL de suspensão, contendo S.marcescens. Após a contaminação, seis diferentes formulações de anti-sépticos (clorexidina e PVP-I nos veículos alcoólico, degermante e aquoso) foram distribuídas e submetidas à cultura diária durante sete dias, a fim de verificar se houve crescimento do microrganismo. Os resultados desta investigação permitem a recomendação de que a limpeza como procedimento mínimo no processamento desses recipientes garante a segurança de sua utilização repetida para distribuição dos anti-sépticos testados - CHX e PVP-I