30,597 research outputs found

    Towards Large-scale Inconsistency Measurement

    Full text link
    We investigate the problem of inconsistency measurement on large knowledge bases by considering stream-based inconsistency measurement, i.e., we investigate inconsistency measures that cannot consider a knowledge base as a whole but process it within a stream. For that, we present, first, a novel inconsistency measure that is apt to be applied to the streaming case and, second, stream-based approximations for the new and some existing inconsistency measures. We conduct an extensive empirical analysis on the behavior of these inconsistency measures on large knowledge bases, in terms of runtime, accuracy, and scalability. We conclude that for two of these measures, the approximation of the new inconsistency measure and an approximation of the contension inconsistency measure, large-scale inconsistency measurement is feasible.Comment: International Workshop on Reactive Concepts in Knowledge Representation (ReactKnow 2014), co-located with the 21st European Conference on Artificial Intelligence (ECAI 2014). Proceedings of the International Workshop on Reactive Concepts in Knowledge Representation (ReactKnow 2014), pages 63-70, technical report, ISSN 1430-3701, Leipzig University, 2014. http://nbn-resolving.de/urn:nbn:de:bsz:15-qucosa-15056

    Instrumentation for measuring the dynamic pressure on rotating compressor blades

    Get PDF
    To establish the capability for measurement of oscillatory pressure on rotating blades, miniature fast response semiconductor strain gage pressure transducers (2mm x 0.33mm) were mounted in several configurations on thin titanium and steel compressor blades and subjected to pressure cycles from 1 to 310 kPa during static tests and spin tests. Static test conditions included 20 C to 150 C, 0 to 3000 tensile microstrain, -1000 to +1000 bending microstrain and + or - 650G vibration. The spin test conditions included 20 C to 82 C at 0 to 90,000G. Durability was excellent. Pressure transducer sensitivity changed by only a few percent over this range of environmental conditions. Noise signal due to oscillatory acceleration normal to the diaphragm was acceptable (0.33Pa/G). Noise signal due to oscillatory strain was acceptable (0.5 Pa/microstrain) when the transducer was mounted on a 0.05mm rubber pad, with a total buildup of 0.38mm on the measure surface. Back mounting or partial recessing to eliminate buildup, increased the strain effect to 1.2 Pa/microstrain. Flush mounting within the blade to eliminate buildup reduced the strain effect, but required development of a special transducer shape. This transducer was not available in time for spin tests. Unpredictable zero drift + or - 14 kPa ruled out the use of these mounting arrangements for accurate steady-state (D.C.) measurements on rotating blades. The two best configurations fully developed and spin tested were then successfully applied in the NAS3-20606 rotating fan flutter program for quantitative measurement of oscillatory pressure amplitudes

    Design and testing of a contra-rotating tidal current turbine

    Get PDF
    A contra-rotating marine current turbine has a number of attractive features: nearzero reactive torque on the support structure, near-zero swirl in the wake, and high relative inter-rotor rotational speeds. Modified blade element modelling theory has been used to design and predict the characteristics of such a turbine, and a model turbine and test rig have been constructed. Tests in a towing tank demonstrated the feasibility of the concept. Power coefficients were high for such a small model and in excellent agreement with predictions, confirming the accuracy of the computational modelling procedures. High-frequency blade loading data were obtained in the course of the experiments. These show the anticipated dynamic components for a contra-rotating machine. Flow visualization of the wake verified the lack of swirl behind the turbine. A larger machine is presently under construction for sea trials

    Optical enhancement of sensitivity in laser Doppler velocity systems

    Get PDF
    Utilization of optical enhancement techniques prevents loss of light by reflections at the photocathode of a photomultiplier and increases signal detection sensitivity

    Grid-connected renewables, storage and the UK electricity market

    Get PDF
    This article is a critical counterpoint to an article by published by Swift-Hook in the journal of Renewable Energy entitled "Grid-connected intermittent renewables are the last to be stored". In contrast to Swift-Hook we found evidence that "grid-connected intermittent renewables" have been, and will continue to be stored when it suits the "UK market" to do so.  This article is important to policy makers as energy storage (through EV battery demand side management for example) may well have an important role to play in facilitating the integration of high wind penetrations

    Development of a contra-rotating tidal current turbine and analysis of performance

    Get PDF
    A contra-rotating marine current turbine has a number of attractive features: nearzero reactive torque on the support structure, near-zero swirl in the wake, and high relative inter-rotor rotational speeds. Modified blade element modelling theory has been used to design and predict the characteristics of such a turbine, and a model turbine and test rig have been constructed. Tests in a towing tank demonstrated the feasibility of the concept. Power coefficients were high for such a small model and in excellent agreement with predictions, confirming the accuracy of the computational modelling procedures. Highfrequency blade loading data were obtained in the course of the experiments. These show the anticipated dynamic components for a contra-rotating machine. Flow visualization of the wake verified the lack of swirl behind the turbine. A larger machine is presently under construction for sea trials

    Measuring unsteady pressure on rotating compressor blades

    Get PDF
    Miniature semiconductor strain gage pressure transducers mounted in several arrangements were studied. Both surface mountings and recessed flush mountings were tested. Test parameters included mounting arrangement, blade material, temperature, local strain in the acceleration normal to the transducer diaphragm, centripetal acceleration, and pressure. Test results show no failures of transducers or mountings and indicate an uncertainty of unsteady pressure measurement of approximately + or - 6 percent + 0.1 kPa for a typical application. Two configurations were used on a rotating fan flutter program. Examples of transducer data and correction factors are presented

    The NASA Astrophysics Data System: Data Holdings

    Get PDF
    Since its inception in 1993, the ADS Abstract Service has become an indispensable research tool for astronomers and astrophysicists worldwide. In those seven years, much effort has been directed toward improving both the quantity and the quality of references in the database. From the original database of approximately 160,000 astronomy abstracts, our dataset has grown almost tenfold to approximately 1.5 million references covering astronomy, astrophysics, planetary sciences, physics, optics, and engineering. We collect and standardize data from approximately 200 journals and present the resulting information in a uniform, coherent manner. With the cooperation of journal publishers worldwide, we have been able to place scans of full journal articles on-line back to the first volumes of many astronomical journals, and we are able to link to current version of articles, abstracts, and datasets for essentially all of the current astronomy literature. The trend toward electronic publishing in the field, the use of electronic submission of abstracts for journal articles and conference proceedings, and the increasingly prominent use of the World Wide Web to disseminate information have enabled the ADS to build a database unparalleled in other disciplines. The ADS can be accessed at http://adswww.harvard.eduComment: 24 pages, 1 figure, 6 tables, 3 appendice

    Imaging X-ray spectrometer

    Get PDF
    An X-ray spectrometer for providing imaging and energy resolution of an X-ray source is described. This spectrometer is comprised of a thick silicon wafer having an embedded matrix or grid of aluminum completely through the wafer fabricated, for example, by thermal migration. The aluminum matrix defines the walls of a rectangular array of silicon X-ray detector cells or pixels. A thermally diffused aluminum electrode is also formed centrally through each of the silicon cells with biasing means being connected to the aluminum cell walls and causes lateral charge carrier depletion between the cell walls so that incident X-ray energy causes a photoelectric reaction within the silicon producing collectible charge carriers in the form of electrons which are collected and used for imaging
    corecore